title>JB/T 7090-1993 Waste Heat Boiler Parameter Series Oxygen Converter Waste Heat Boiler - JB/T 7090-1993 - Chinese standardNet - bzxz.net
Home > JB > JB/T 7090-1993 Waste Heat Boiler Parameter Series Oxygen Converter Waste Heat Boiler
JB/T 7090-1993 Waste Heat Boiler Parameter Series Oxygen Converter Waste Heat Boiler

Basic Information

Standard ID: JB/T 7090-1993

Standard Name: Waste Heat Boiler Parameter Series Oxygen Converter Waste Heat Boiler

Chinese Name: 余热锅炉参数系列 氧气转炉余热锅炉

Standard category:Machinery Industry Standard (JB)

state:Abolished

Date of Release1993-10-08

Date of Implementation:1994-01-01

Date of Expiration:2006-08-21

standard classification number

Standard Classification Number:Machinery>>Piston Internal Combustion Engine and Other Power Equipment>>J98 Boiler and Auxiliary Equipment

associated standards

Publication information

other information

Introduction to standards:

JB/T 7090-1993 Waste Heat Boiler Parameter Series Oxygen Converter Waste Heat Boiler JB/T7090-1993 Standard Download Decompression Password: www.bzxz.net

Some standard content:

1 Subject content and scope of application
Machinery Industry Standard of the People's Republic of China
Waste heat boiler parameter series
Oxygen converter waste heat boiler
This standard specifies the basic parameters of oxygen converter waste heat boilers. This standard is applicable to various types of oxygen converter waste heat boilers. Technical content
The basic parameters of oxygen converter waste heat boilers are generally specified in the following table. Table
Waste heat steel furnace inlet
Gas volume
X10°m/h
Waste heat boiler inlet
Gas temperature
Approved by the Ministry of Machinery Industry on 1993-10-08
Rated steam pressure
Rated steam temperature
JB/T7090-Www.bzxZ.net
Average steam production during oxygen blowing period
Implemented on 1994-01-01
JB/T7090-93
Note: ① The data in brackets are rarely used in China at present and are generally not adopted. ② The gas volume at the inlet of the waste heat boiler refers to m/h at 0.101MPa (760mmHg), 0C. The feed water temperature of the waste heat boiler is 20℃ when the gas volume is not more than 17.9×10m/h, and 105℃ (with economizer) when the gas volume is more than 17.9×10m/h.
The average steam production during the oxygen blowing period is the theoretical calculated value of full vaporization under the condition of gas volume at the inlet of the waste heat boiler and gas temperature drop △t=600C. Since the steam production changes with the change of gas volume and gas temperature drop, the design unit can adjust it according to the specific situation in the design. Additional remarks:
This standard is proposed by the Ministry of Machinery Industry.
This standard is under the jurisdiction of Hangzhou Waste Heat Boiler Research Institute. This standard is drafted by Shanghai Hujiang Machinery Factory. The main drafters of this standard are Bingkui, Li Yufu, Zheng Faqing and Li Yunsen.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.