Some standard content:
Light Industry Standard of the People's Republic of China
Metal ceiling
Metal ceiling
1 Subject content and scope of application
QB/T1561-1992
This standard specifies the product classification, technical requirements, test methods, inspection rules, marking, packaging, transportation and storage of metal ceilings. This standard applies to metal ceilings used for building decoration in combination with light steel keels. 2 Reference standards
GB/T1720
GB/T1732
GB/T1764
GB/T1958
GB/T2828
GB/T2829
GB5928
GB5938
GB5944
3'Product classification
3.1 Type
Determination of paint film adhesion
Determination of paint film impact resistance
Determination of paint film thickness
Provisions for shape and position tolerance inspection
Count sampling procedure and sampling table for batch inspection (applicable to inspection of continuous batches)Count sampling procedure and sampling table for periodic inspection (applicable to inspection of production process stability)Thickness test method of metal coating and aluminum oxide film of light industrial productsWeight measurement methodCorrosion resistance test method of metal coating and chemical treatment layer of light industrial productsNeutral salt spray test (NSS) method
Evaluation of corrosion test results of metal coating of light industrial products3.1.1 Classification by shape
The code for strip plate shape is T (see Figure 1);
The code for block plate shape is K (see Figure 2);
The code for grid shape is G (see Figure 3).
Approved by the Ministry of Light Industry of the People's Republic of China on July 6, 1992B
Implemented on March 1, 1993
Note: The figure is an example of the type, not a typical composition. 3.1.2 According to the material, the code for aluminum alloy is L; the code for Z; the code for B; the code for H. According to the surface treatment, the code for aluminum alloy oxidation is Y; 3.2 Specifications are D; the code for Q; the code for S. QB/T1561-1992 The size specifications of strip-shaped panels shall comply with the provisions of Table 1. Table 1
Basic size
Limit deviation
First-class product
Qualified product
Limit deviation
QB/T1561-1992
3.2.2 Specifications of block-type panels shall comply with the provisions of Table 2. Table 2
3.2.3 Product code
Basic size
400×400
500X500
600×600
500X1000
600×1200
Surface treatment
Metal ceiling
Note: Strip board specifications are BXHXL; block board specifications are BXA; grid-shaped specifications are not indicated. 3.2.4 Marking examples
Limit deviation
Example 1: Surface oxidized strip-shaped aluminum alloy metal ceiling item with a length of 6000mm, a width of 80mm and a height of 12mm. Metal ceiling JDTLY-80X12X6000QB/T1561--1992mm
QB/T1561--1992
Example 2: Surface sprayed grid-shaped aluminum alloy metal ceiling. Metal ceiling JDGLSQB/T1561-1992
4 Technical requirements
4.1 Strength
4.1.1 After the panel and the keel are installed, the panel should be able to withstand a static load of 160N/m2, the maximum elastic deformation shall not be greater than 10mm, and the plastic deformation shall not be greater than 2mm.
4.1.2 The hanging parts required for installing the panel should be able to withstand a static tensile force of 150N without obvious plastic deformation. 4.2 Accuracy
4.2.1 The panel size and deviation should comply with the provisions of Table 1 and Table 2, and the length of the strip board should not be less than the nominal size. 4.2.2 The edges of the strip board, block board, and grid-shaped panels should be straight, and the maximum curvature should not be less than 3%. 4.3 Panel surface quality
4.3.1 The surface of the panel should be smooth, flat, with clear patterns and basically consistent colors, without obvious scratches and burrs. The paint film and spray-coated layer shall not have exposed bottom and obvious sags, bubbles, orange peel and other defects. 4.3.2
The oxide layer shall not have looseness and spots and other defects.
The electroplating layer shall not have bubbles, exposed bottom, or shedding, and shall not have obvious black spots, pitting and other defects. The adhesion of the paint film shall not be lower than that specified in Table 3. Table 3
Qualified products
4.3.6 The adhesion of the spray coating shall not be less than that specified in Table 4. Product grade
Qualified products
4.3.7 The thickness of the aluminum oxide film shall not be less than that specified in Table 5. Product grade
Qualified products
4.3.8 The corrosion resistance of the electroplating layer shall not be less than that specified in Table 6. Product grade
"Qualified product
4.3.9 The thickness of the sprayed plastic layer should not be less than 60μm. Table 4
Test time, h
The impact strength of the sprayed plastic layer should not be less than that specified in Table 7. 4.3.10
Paint film adhesion level, level
Sprayed plastic layer adhesion level, level
Aluminum oxide film thickness μm
Electroplating layer corrosion resistance level, level
Product grade
Qualified product
4.4 The hanging parts should be treated with anti-corrosion.
5 Test method
5.1 Strength
QB/T1561-1992
Impact strength of sprayed plastic layer, N·m
5.1.1 Test for 4.1.1: (See Figure 4) Apply a uniform load to the panel according to the actual installation method (the area shall not be less than 1m2), take the center line between the two keels as the measuring line, and take several measuring points on the measuring line (not less than 3). After holding the load for 60s, measure the deformation of each measuring point, and the largest value is the maximum elastic deformation. After 60s of unloading, measure the residual deformation at each measuring point, and take the maximum value as the plastic deformation. The deformation is detected with a dial indicator.
5.1.2 Test for Article 4.1.2: Install the hanging parts on the tensile machine, apply force to both ends to the specified value, and hold the load for 60s. 1200
Uniform load
-1m\square wooden board
Dial indicator
Measuring line
Keel bracket
5.2 Accuracy
QB/T1561-1992
Measuring line
Continued Figure 4
Uniformly distributed load
1m wooden board
Block panel
Dial indicator
Keel bracket
5.2.1 For the test of Article 4.2.1: B and H in Table 1 are tested with a vernier caliper with an indication of 0.02mm, and L is tested with a steel tape measure. BXA in Table 2 is tested with a steel tape measure with an indication of 1mm.
5.2.2 For the test of Article 4.2.2: Use a steel ruler or flat plate with a feeler gauge. 5.3 Panel surface quality
5.3.1 For the test of Articles 4.3.1 to 4.3.4: Use hand feel and visual inspection. 5.3.2 For the test of Articles 4.3.5 and 4.3.6: According to GB/T1 720 for testing and rating. 5.3.3 Test for 4.3.7: Conduct according to GB5928. 5.3.4 Test for 4.3.8: Conduct according to GB5938, the surface area of the sample shall not be less than 1dm2, and be evaluated according to GB5944. 5.3.5 Test for 4.3.9: Conduct according to Chapter 3 B of GB/T1764 - Magnetic Thickness Gauge. 5.3.6 Test for 4.3.10: Conduct testing and rating according to GB/T1732. 5.4 Test for 4.4: Conduct by hand feel and visual inspection. 6 Inspection Rules
Product inspection is divided into factory inspection and type inspection. 6.1 Factory Inspection
6.1.1 Products must be inspected and qualified by the inspection department of the manufacturer before they can leave the factory. The recipient has the right to re-inspect the delivery batch. 6.1.2 Factory inspection shall be carried out in accordance with the provisions of GB/T2828, using the general inspection level I, normal inspection-sub sampling plan. 6.1.3 The unqualified categories and qualified quality levels (AQL) shall be as specified in Table 8. 362bzxz.net
Inspection items
Panel surface quality
Panel size
6.2 Type inspection
QB/T1561--1992
Inspection clauses
Unqualified categories
Type inspection shall be carried out in accordance with the provisions of GB/T2829, using the discrimination level I and the sampling plan. Type inspection shall be carried out when one of the following situations is encountered. Test and finalization of new products or old products for transfer to factory production; after formal production, if there are major changes in structure, materials, and processes, which may affect product performance; when the product is resumed after being discontinued for half a year; d.
After one year of normal production;
When the factory inspection results are significantly different from the last type inspection. Acceptable quality level (AQL)
Type inspection samples shall be extracted from the submitted batch, and its inspection items, inspection clauses, and discrimination arrays (A., R.) Unqualified quality level (RQL) shall be carried out in accordance with the provisions of Table 9.
Inspection items
Adhesion of paint film
Adhesion of sprayed plastic layer
Temperature of aluminum oxide film
Corrosion resistance of electroplating layer
Thickness of inkjet layer
Impact strength of sprayed plastic layer
Hanging parts
Inspection clauses
Number of samples
Note: The number of samples for strength shall not be less than 1m2 according to the actual installation method.7 Marking, packaging, transportation, storage
7.1 Marking
Discrimination array
Unqualified quality level
The packaging box shall be marked with the manufacturer's name, product code, net weight, gross weight, place of origin, trademark, grade, quantity, date of manufacture and the "beware of moisture" mark.
7.2 Packaging
7.2.1 Metal ceiling panels and accessories are packed separately. 7.2.2 The panel is packed with wrapping paper and then packed into a packing box. The packing box should be accompanied by a certificate of conformity and a packing list. 7.3 Transportation
The product must not be exposed to moisture or magnetic shock during transportation. 7.4 Storage
QB/T1561--1992
The product should be stored in a ventilated and dry warehouse, and the bottom of the box should be more than 200mm above the ground. ) There is no corrosive gas near the storage area, and the relative humidity is less than 80%. The shelf life is one year under the above conditions. Additional remarks:
This standard is proposed by the Quality Standards Department of the Ministry of Light Industry. This standard is under the jurisdiction of the National Building Hardware Standardization Center. This standard is drafted by Shanghai Building Hardware Industry Research Institute, Beijing Building Light Steel Structure Factory, Changzhou Honglian Lighting Company, Minhang Metal Products Company, and Linmao Metal Products Co., Ltd. The main drafters of this standard are Yu Wei, Wu Yunzhi, Wang Mei, Zhou Wenjun, Shen Fugen, Xue Jinxiang, Jia Baoshan, Liu Huacheng and Ma Minglei.