This standard specifies the type, basic parameters and dimensions, technical requirements, test methods and inspection rules, marking, packaging and warranty requirements of the YEJ series electromagnetic brake three-phase asynchronous motor. This standard applies to the YEJ series (IP44) electromagnetic brake three-phase asynchronous motor (frame size 80-225) (hereinafter referred to as the motor), and all derived series of motors derived from this series of motors can also refer to it. JB/T 6456-1992 Technical conditions for YEJ series (IP44) electromagnetic brake three-phase asynchronous motor (frame size 80~225) JB/T6456-1992 Standard download decompression password: www.bzxz.net
Some standard content:
Mechanical Industry Standard of the People's Republic of China JB/T6456-1992 Technical conditions for YEJ series (IP44) electromagnetic brake three-phase asynchronous motors Frame size 80~225) Published on August 6, 1992 Implementation by the Ministry of Machinery and Electronics Industry of the People's Republic of China on January 1, 1993 Mechanical Industry Standard of the People's Republic of China Technical conditions for YEJ series (IP44) electromagnetic brake three-phase asynchronous motors (Frame size 80~225) Subject content and scope of application JB/T6456-1992 This standard specifies the type, basic parameters and dimensions, technical requirements, test methods and inspection rules, marking, packaging and warranty period requirements of YEJ series electromagnetic brake three-phase asynchronous motors. This standard applies to YEJ series (IP44) electromagnetic brake three-phase asynchronous motor (frame size 80~225) (hereinafter referred to as motor), and all derived series motors derived from this series of motors can also refer to it for implementation. Reference standards Rotating motor GB1993 Basic technical requirements Motor housing protection classification Motor cooling method Motor structure and installation type code Motor size and tolerance Packaging storage and transportation graphic mark GB12665 GB10069 GB10068 GB1032 JB/Z294 JB/Z346 Frame size 36~400 Flange number FF55~FF1080 or FT55~ FT1080 motorsDamp heat test requirements for motors used under general environmental conditionsRotating motors Noise measurement method and limit value Vibration measurement method and limit value Rotating motors Three-phase asynchronous motor test methods AC low-voltage motor scattered winding turn-to-turn insulation test methodsAC low-voltage motor scattered winding turn-to-turn insulation test limit valueType, basic parameters and dimensions The enclosure protection level of the motor is IP44 (see GB4942.1), of which the electromagnetic brake part has a protection level of IP23.3.2 The cooling method of the motor is IC0141 (see GB1993). 3.3 The structure and installation type of the motor are IMB3, IMB5, IMB6, IMB7, IMB8, and LMB35 (see GB997), and are manufactured according to the provisions of Table 1. 80~160 180~225 The rating of the motor is the continuous rating based on the continuous duty system (S1). 3.4 The Ministry of Machinery and Electronics Industry of the People's Republic of China approved the structure and installation code (IM) on August 6, 1992 Implementation on January 1, 1993 JB/T6456-1992 3.5 The rated frequency of the motor is 50Hz, the rated voltage is 380V, the stator winding power is 3kW or less, the Y connection method is adopted, and the other powers are all △ connection method. The rated voltage of the electromagnetic brake is 170V DC for motor center height H112 and above, and 3.6V DC for motor center height H100 and below. The motor should be manufactured according to the following rated powers: 0.55, 0.75, 1.1, 1.5, 2.2, 3, 4, 5.5, 7.5, 11, 15, 18.5, 22, 30, 3745kW3.8The corresponding relationship between the motor frame number, speed and power should be in accordance with the provisions of Table 2. Table 2 132s 2 200L! Note: The numbers 1 and 2 after S, M and L represent different powers under the same frame and speed. 9 Motor size and tolerance Speed, t/min The installation size and tolerance of the motor should comply with the provisions of Tables 3 to 5, and the external dimensions should not be greater than those in Tables 3 to 5. Draw (02 +4-(01) 08 expect the receiver to slide 3(1a 1005*010 600*0+ 691816 JB/T 64561992 There are 15 pages left to read. Do you want to continue reading? This document was shared by 342601zyg on 2020-03-21. Continue to read the full text for free Users who have read this document also read these documentsGUB Health quality Don't read it, download it directly 》SMy installation inspection part is required to be JB/T6456 JB/T64561992 The dimensions and tolerances of the motor shaft extension chain shall comply with the provisions of Table 6. Table 6 Auxiliary extension diameter 8- a36 10-0n36 12_0043 14-8n43 18-n43 The radial runout tolerance at half the length of the motor shaft extension shall comply with the provisions of Table 7. Table 7 Shaft extension diameter >30~50 >50~60 How many stoppers are aligned with the motor axis 6-8anao g_ sgo 10-0n90 11-810 late moving public JB/T64561992 The dimensions and tolerances of the motor shaft extension chain shall conform to the provisions of Table 6. Table 6 Shaft extension diameter 10-0n36 12-0043 14_8n43 16-003||t t||The radial runout tolerance at half the motor shaft extension length shall comply with the provisions of Table 7. Table 7 >30~50 >50~60 9-0190 10-000 4 The radial runout tolerance of the flange stop to the motor axis and the end face runout tolerance of the flange mating surface to the motor axis shall comply with the provisions of Table 8. ||tt ||Flange stop diameter 130~230 >230~350 Medical runout tolerance The parallelism tolerance of the motor axis to the foot support surface and the flatness tolerance of the foot support surface shall comply with the provisions of Table 9. Table 9 80~112 132~200 Parallelism tolerance The symmetry tolerance of the keyway on the motor shaft extension shall comply with The motor shall meet the requirements of Table 10. Table 10 Symmetry Flatness tolerance Technical requirements JB/T6456-1992 The motor shall meet the requirements of this standard and be manufactured in accordance with the drawings and technical documents approved by the prescribed procedures. 4.1 4.2 The motor shall be able to operate at rated altitude, ambient air temperature and ambient air relative humidity under the following conditions. The altitude shall not exceed 1000m. 4.2.2 The maximum ambient air temperature varies with the season, but shall not exceed 40℃. Note: If the motor is specified to be used at an altitude exceeding 1000m or the ambient air temperature is higher or lower than 40℃, the provisions of GB755 shall be followed. 4.2.3 The minimum ambient air temperature is -15℃. The average maximum relative humidity of the wettest month is 90%, and the average minimum temperature of the month is not higher than 25℃. 4.2.4 During the operation of the motor, the deviation of the power supply voltage and frequency from the rated value shall comply with the provisions of GB755. 4.3 When the power, voltage and frequency of the motor are rated, the guaranteed values of its efficiency and power factor shall comply with the provisions of Table 11. Table 11 Efficiency,"% Speed,/minwwW.bzxz.Net Note: The efficiency is determined by the actual measured stray loss analysis method, and the loss does not include the excitation loss of the electromagnetic brake. 1500 Power factor, co JB/T64561992 At rated voltage, the guaranteed value of the ratio of the motor's stall torque to the rated torque shall comply with the provisions of Table 12. Table 12 Synchronous speed/min Staple torque/rated torque JB/T64561992 4.6 Under rated voltage, the guaranteed value of the ratio of the minimum torque to the rated torque during the motor starting process shall comply with the provisions of Table 13. Table 13 Speed, r/min Minimum torque/rated torque JB/T6456-1992 Under rated voltage, the guaranteed value of the ratio of the maximum torque to the rated torque of the motor shall comply with the provisions of Table 14. Table 14 Synchronous speed r/min Maximum torque/rated torque Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.