title>JB/T 5163-1991 Technical requirements for electric fence pulsers - JB/T 5163-1991 - Chinese standardNet - bzxz.net
Home > JB > JB/T 5163-1991 Technical requirements for electric fence pulsers
JB/T 5163-1991 Technical requirements for electric fence pulsers

Basic Information

Standard ID: JB/T 5163-1991

Standard Name: Technical requirements for electric fence pulsers

Chinese Name: 电围栏脉冲器 技术条件

Standard category:Machinery Industry Standard (JB)

state:Abolished

Date of Release1991-05-18

Date of Implementation:1992-01-01

Date of Expiration:2008-01-01

standard classification number

Standard Classification Number:Agriculture, Forestry>>Agricultural and Forestry Machinery and Equipment>>B95 Forestry Machinery and Equipment

associated standards

alternative situation:Replaced by JB/T 5163-2007

Publication information

other information

Focal point unit:Hohhot Animal Husbandry Machinery Research Institute

Introduction to standards:

This standard specifies the terminology, type, technical requirements, inspection rules, marking, packaging, transportation and storage requirements of electric fence pulsers. JB/T 5163-1991 Technical conditions for electric fence pulsers JB/T5163-1991 Standard download decompression password: www.bzxz.net

Some standard content:

Mechanical Industry Standard of the People's Republic of China
JB/T5163-1991
Electric Fence Pulser
Published on 1991-05-18
Technical Conditions
Implementation on 1992-01-01
Published by the Ministry of Machinery and Electronics Industry of the People's Republic of China
Mechanical Industry Standard of the People's Republic of China
Electric Fence Pulser
1 Subject Content and Scope of Application
Technical Conditions
JB/T 51631991
This standard specifies the terminology, types, technical requirements, inspection rules, marking, packaging, transportation and storage requirements of electric fence pulsers. This standard applies to various types of electric fence pulsers used in animal husbandry production. Cited standards
ZBB92005
JB/T5164
3 Terms
Fence terms
Electric fence pulser
3.1 Electric fence pulser
Test method
A device that can convert general forms of electrical energy into high-voltage, high-current sharp pulse signals with a certain time interval and transmit them to the fence line.
3.2 Maximum transmission distance
The maximum fence line length that the electric fence pulser can carry. Converted into a single line, in km. 3.3 Other terms related to fences should comply with the provisions of ZBB92005. 4 Types
4.1 Electric fence pulsers are divided into the following according to output characteristics: a. Low resistance/high current type;
b. High resistance/high voltage type.
4.2 Electric fence pulsers are divided into the following categories according to the power supply: a. AC type;
b. DC type;
c. AC and DC dual-purpose type.
5 Technical requirements
Electric fence pulsers shall comply with the provisions of this standard and be manufactured according to the drawings and technical documents approved by the prescribed procedures. Electric fence pulsers shall be able to work continuously and reliably under the following conditions. 5.2
5.2.1 Ambient temperature: -25~+40℃.
Relative humidity of air: <85% (at 25℃). 5.2.2
The surrounding medium shall not be explosive, and shall not contain conductive dust or corrosive gases that can damage metals and insulation. 5.2.3bzxZ.net
5.2.4 The power supply voltage shall meet the following requirements: a: AC power supply allowable range: rated voltage ±10%; approved by the Ministry of Machinery and Electronics Industry on May 18, 1991 and implemented on January 1, 1992
JB/T5163-1991
b. DC power supply allowable range: rated voltage ±15%. 3 The maximum transmission distance of the electric fence pulser under the rated power supply voltage should not be less than 95% of the nominal value. 5.3
The output characteristics of the electric fence pulser under the rated power supply voltage should meet the requirements of Table 1. Table 1
Test conditions
Low resistance/high current type
High resistance/high voltage type
Voltage peak value
2000-8000
2000~10000
Current peak value
Pulse width
Each pulse
On 5002 simulated load
Pulse period
The live parts of the AC power supply terminal of the AC and DC dual-purpose electric fence pulser and the exposed metal shell and the grounding electrode should be able to withstand a withstand voltage test with a frequency of 50Hz and an AC voltage of 1500V for 1min without breakdown or flashover.
5.6 After the AC and AC/DC electric fence pulsers are placed in an environment with a temperature of 40±2℃ and a relative humidity of 95%±3% for 48 hours, their insulation performance shall meet the following requirements under non-condensing conditions: a. The insulation resistance shall not be less than 1M2;
b. It shall be able to withstand an AC withstand voltage test of 1000V, 50Hz for 1 minute without breakdown and flashover. The test parts of the above two items shall comply with the provisions of Article 5.5 of this standard. 5.7 Under the following overvoltage conditions, the electric fence pulser shall run at no load for 5 minutes, and the components shall not be damaged. a. The AC power supply is 120% of the rated power supply voltage; b. The DC power supply is 130% of the rated power supply voltage. The electric fence pulser must have lightning protection devices or measures. 5.8
The power consumption performance of the whole machine shall meet the requirements of Table 2.
Low resistance/high current type
High resistance/high voltage type
Note: The values ​​given in the table are arithmetic mean values.
≤20W
) For electric fence pulsers with automatic control function, their automatic control performance shall meet the following requirements: 5.10
a. The automatic control effectiveness shall not be less than 90%;
b. The delay of automatic control shall not be greater than one pulse cycle. 5.11 The working time of the electric fence pulser before the first failure shall not be less than 5000h. DC type
5.12 The casing, front and rear panels and other exposed parts of the electric fence pulser shall be firmly painted, with a smooth surface and uniform color, and no defects that damage the appearance.
Various signs and
nameplates shall be complete and clear.
Test method
Perform according to the provisions of JB/T5164.
Inspection rules
Product inspection is divided into factory inspection and type inspection 7.1 Factory inspection
JB/T 51631991
Products should be inspected one by one before leaving the factory, and the inspection items shall be carried out in accordance with the items specified in Article 5.4 of this standard. Products whose various technical performance indicators meet the requirements of Table 1 are qualified products. 7.2 Type inspection
7.2.1 Type inspection shall be carried out in any of the following situations: a. When new products are trial-produced;
b. For finalized products, when the design or process changes are sufficient to cause changes in certain performance parameters of the product; c. For products that are not frequently produced, when they are produced again; d. For products that are normally continuously produced, at least once every two years. 7.2.2
Inspection items shall be carried out item by item in accordance with the items specified in Articles 5.3 to 5.11 of this standard. The sample for type inspection shall be no less than 3 sets and shall be randomly selected from the product batch. If one item fails in the type inspection, double the number of samples shall be selected from the same batch of products for repeated inspection; if there is still one item that fails, the batch of products shall be judged as unqualified. : Marking, packaging, transportation, storage
8.1 Product marking shall include the following:
a. Manufacturer name and trademark;
b. Product name and model;
c. Factory number;
d. Factory date.
8.2 Product packaging shall comply with the regulations of the relevant transportation department and shall not be damp or mechanically damaged during transportation. 8.3 The following signs should be clearly marked on the packaging box with non-fading paint: a. Product name and specifications;
b. Product quantity;
c. Gross weight of the packaging box, kg;
d. Manufacturer's name;
e. Dimensions of the packaging box: length × width × height, cm; f. Precautions: "Handle with care", "Do not get wet" and other words or symbols; g. Date of manufacture.
8.4 The following documents should be included in the packaging box: a. Inspection certificate;
b. Packing list;
c. Instruction manual.
JB/T5163-1991
5 The product should be suitable for general road and rail transportation. During transportation, it must be ensured that it is not damaged, rained, severely vibrated or impacted. 8.5
8.6 The product should be stored in a dry, well-ventilated warehouse without corrosive gases. Additional Notes:
This standard was proposed and managed by the Hohhot Animal Husbandry Machinery Research Institute of the Ministry of Machinery and Electronics Industry. This standard was drafted by the Hohhot Animal Husbandry Machinery Research Institute of the Ministry of Machinery and Electronics Industry. The main drafters of this standard were Zhang Ying and Hada. 4
People's Republic of China
Mechanical Industry Standard
Technical Conditions for Electric Fence Pulser
JB/T51631991
Published and issued by the China Academy of Mechanical Science
Printed by the China Academy of Mechanical Science
(No. 2 Shouti South Road, Beijing
Postal Code 100044)
Format 880×1230
Sheet 1/2
Word Count 6.000
First Edition in September 1991
First Printing in September 1991
Print Quantity 1-500
Price 0.80 Yuan
Mechanical Industry Standard Service Network: http://www.JB.ac.cn1661_9 /