Standard ICS number:Shipbuilding and offshore structures>>Shipbuilding and offshore structures in general>>47.020.90 Marine ventilation, air conditioning and heating systems
Standard Classification Number:Ship>>Ship Pipe Accessories>>U54 Marine Ventilation Accessories
This standard specifies the product classification, technical requirements, test methods, inspection rules, marking, transportation and packaging of air duct dampers. This standard applies to air duct dampers in various types of ship ventilation systems. This standard does not apply to insulated spiral air duct dampers. CB/T 3726-1995 Air duct dampers CB/T3726-1995 Standard download decompression password: www.bzxz.net
Some standard content:
Shipbuilding Industry Standard of the People's Republic of China CB/T 3726--1995 Air Duct Damper Published on 1995-12-19 Published by China State Shipbuilding Corporation Implemented on 1996-08-01 Shipbuilding Industry Standard of the People's Republic of China Subject Content and Scope of Application CB/T3726--1995 Classification Number: U54 Replacement: CB463--66 CB668-68 CB*458—85 CB542--80 This standard specifies the product classification, technical requirements, inspection rules and markings of air duct dampers (hereinafter referred to as dampers). This standard is applicable to air duct dampers in ventilation systems of various types of ships. This standard does not apply to insulated spiral duct dampers. 2 Reference standards GB3029 Marine ventilation accessories Technical conditions CB"/Z54 electrolytic galvanizing 3 Product classification The types of dampers are as shown in Table 1. Circular ordinary damper Circular sealed damper Circular simple damper Rectangular simple damper Rectangular handle damper Rectangular pull ring damper Rectangular hinge damper China State Shipbuilding Corporation 1995-12-19 Approved Nominal diameter DN 80~400 80~700 Installation position Used in the middle of circular ventilation ducts Used for circular ventilation pipes with sealing requirements|| tt||Middle part of air duct Used in the middle part of circular ventilation duct Used in the middle part of rectangular ventilation duct Used in the middle part of rectangular ventilation duct And outlet end (used for removing flange net in the middle part of the duct) Used in the outlet end of rectangular ventilation duct 1996-08-01 implementation CB/T3726-1995 3.2The structural type and main dimensions of type A damper shall be in accordance with Figure 1 and Table 2. DN 1—body; 2—damper plate; 3-stuffing box; 4-handleTable 2 Nominal diameter of air duct Main dimensions of damper Number of bolt holes n(pieces) CB/T3726—1995||tt| |3.3The structural type and main dimensions of the B-type air damper are as shown in Figure 2 and Table 3. D Nominal diameter of air duct 1—body; 2 air damper; 3—shaft; 4 cup-shaped sleeve; 5—handle; 6—stuffing box Table 3 Main dimensions of air damper Number of bolt holes n(pieces) CB/T3726-1995 3.4C-type The structural type and main dimensions of the damper shall be in accordance with Figure 3 and Table 4. Figure 3 1 Main body, 2 Air regulating plate; 3-Shaft; 4-Handle Table 4 Nominal diameter of air duct Main dimensions of damper CB/T3726-1995 3.5The structural type and main dimensions of D-type damper shall be in accordance with Figure 4 and Table 5.2.5 1 Main body; 2-Air regulating plate; 3—axis; 4—handle Table 5 Nominal diameter Nominal size Main dimensions of air damper Nominal diameter Nominal size CB/T3726-1995 Continued Table 5 Main dimensions of air damper CB/T3726--1995 3.6 Structure of E air damper The configuration and main dimensions are as shown in Figure 5 and Table 6. Figure 5 1—main body; 2—air regulating plate; 3—shaft; 4—handleTable 6 Nominal size Flange size 115×145 115×195 135×175 115×275 135×215 155×18 5 135×305 155×255 175×205 135×405 155×305 175×265 155X405 175×335 206 ||65×95 65×14 5 85×125 65×225 85×165 105×135 85×255 105×205 85×355 105×255 12 5×215 105X355|| tt||125×285 156X×226 Main dimensions of air damper Screw hole distance Number of bolt holes n (pcs) Short side 1 Nominal dimensions Flange dimensions 175×525 206×406 246×336 206×5 86 246 × 446 ||tt | tt||350×640 410 ×540 | tt||196×556 247 × 427 | | tt | | 300 × 370 | | tt | | 196 × 766 | | tt | | 247 × 557 | | tt | | 300 × 470 | | tt | 740 360×610||tt ||350X1160 300×1110 410×940 480X770 410×1300 360×890 430X720 360×1250 480×1050||tt ||430×1000 56 0×870 510×820 CB/T3726—1995 Continued Table 6 Main dimensions of air damper Screw hole distance Number of bolt holes n (pieces) Total of long sides CB/T3726-1995 The structural type and main dimensions of F-type air damper are as shown in Figure 6 and Table 7. 3.7 1 body; 2 air regulating plate; 3 shaft; 4 connecting plate; 5 pull ring gauge 7 Nominal size Flange size 115×145 115×195 135×175 115×275 135×215 155×185 135×305 1 55 × 255 | | tt | | 175 × 205 | | tt | | 135 × 405 | | tt | |105×135 85×255 105×205 125×155 85×355 105×255 125×215 Main dimensions of air damper Screw hole distance Number of bolt holes n Full length Nominal dimensions Flange dimensions 155X405 175×355|| tt||206 × 276 | 350×420 246×816 29 7 × 607 | | tt | | 350 × 520 | | tt | 156×226 125×475 156×356 196×286 156×536 196×396 247X307 196×556 247X427bzxz.net 300×370 196×766 247×557 300×470 247 × 737 | | tt | | 300 × 590 | | tt | | 360X490 | | tt | 0×770 410X1.300 4 80×1050 560X870 360×890 430×720 360×1250 430×1000 510×820 CB/T3726--1995 Continued Table 7 Main dimensions of air damper Screw hole distance Number of bolt holes n Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.