GB/T 3069.1-1986 Determination of naphthalene ash content GB/T3069.1-1986 Standard download decompression password: www.bzxz.net
Some standard content:
National Standard of the People's Republic of China Method for the determination of the. sh content; of :naphthalebetDC 668.796.3 CB 3068.1--86 Replaces GB3060.1-82 This standard is applicable to the determination of ash content in the tantalum fraction obtained by fractionation of high-temperature coal tar, refined tea, industrial tantalum and pressed naphthalene obtained by washing, rectification or pressing. Test Principle Incinerate the non-volatile matter of naphthalene, and the percentage of the residue after incineration in the weighed naphthalene sample is taken as the ash content. 2. Sample collection and preparation Solid samples shall be collected in accordance with GB2000-80 "Sampling Method for Solid Coking Products", and liquid samples shall be collected in accordance with GB2289-80 "Sampling Method for Viscous Oil Coking Products". The sample obtained by the final reduction shall be ground into powder with a mortar. 3. Instruments and equipment 3.1 Box-shaped high-temperature furnace: with a temperature control device, which can maintain a temperature of 815+10℃. It is equipped with a thermocouple and a pyrometer. The back of the furnace has a small hole for inserting the thermocouple. The position of the small hole should ensure that the hot contact point of the thermocouple can be kept 20 to 30 meters away from the bottom of the furnace in the furnace. The furnace door 1 has a vent, as shown in the figure. 一烟图:2—小门后炉:3—接支:1—烟道瓷管:5—温度相关瓷管,6—隔层套:7—炉芯:8—暖隔层;9—炉支脚,10—角钢角架;11—铁炉后,12—护门,13—护口往:箱型温度炉则有适当的温度区,其温度流体流量不得免815±5。温度温度区是关的用温度相关。 Thermocouple with protection tube is calibrated every six months. Issued by National Bureau of Standards on 1986-08-13 Implemented on 1987-08-01 3.2 Evaporation furnace, porcelain, volume 50ml. 3.3 Analytical balance, sensitivity 0,0001g. 、Test steps GB 8069-188 4.1 When determining the ash content of squeezed naphthalene, weigh 20g of the sample (accurate to 0.1g), place it in an evaporating dish that has been pre-burned at 815℃ and has reached constant weight, and slowly heat it with a low fire until there is no volatile matter. 4.2 Place the above squeezed naphthalene residue without volatile matter or the refined naphthalene or the residue of the above naphthalene after the determination of non-volatile matter in a box-shaped high-temperature furnace, ash it at 815+10℃ for 30min, take it out and cool it in the air for 5min, then cool it to room temperature in a desiccator and weigh it (accurate to 0.0002g). 4.3 After weighing, perform a constant weight check, burn it for 15min each time, until the mass difference is within 0.0004g for two consecutive times. The last weighing number is used for calculation. 5 CalculationbZxz.net Ash content (A) is calculated as follows: A1 (%) = Formula: Af— ash content; m2-mi×100 mass of evaporating blood, & mass of evaporating dish and residue after burning, 8-mass of evaporating dish and sample, g. Additional remarks: This standard is proposed by the Ministry of Metallurgical Industry of the People's Republic of China. This standard is drafted by Anshan Iron and Steel Company and Anshan Thermal Energy Research Institute. The seven drafters of this standard are Yin Xiaorong, Wai Guizhi and Lv Xiuqian. From the implementation of the Baimu standard, the original Ministry of Metallurgical Industry's YB292-75 will be invalid. Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.