title>GB/T 15064.4-1994 Test method for graphite emulsion of picture tubes - Adhesion test method - GB/T 15064.4-1994 - Chinese standardNet - bzxz.net
Home > GB > GB/T 15064.4-1994 Test method for graphite emulsion of picture tubes - Adhesion test method
GB/T 15064.4-1994 Test method for graphite emulsion of picture tubes - Adhesion test method

Basic Information

Standard ID: GB/T 15064.4-1994

Standard Name: Test method for graphite emulsion of picture tubes - Adhesion test method

Chinese Name: 显象管石墨乳试验方法 附着性试验方法

Standard category:National Standard (GB)

state:Abolished

Date of Release1994-04-18

Date of Implementation:1994-01-02

Date of Expiration:2009-04-01

standard classification number

Standard ICS number:Electrical Engineering >> 29.040 Insulating Fluids

Standard Classification Number:Building Materials>>Carbon Materials>>Q51 Graphite Materials

associated standards

alternative situation:Replaced by GB/T 15064-2008

Publication information

publishing house:China Standards Press

other information

Release date:1994-04-18

Review date:2004-10-14

drafter:Liu Huidong, Yan Zaijin, Zhang Youyuan, Liu Youhong

Drafting unit:Shandong Nanshu Graphite Mine and Xianyang Nonmetallic Mineral Research Institute of National Building Materials Bureau

Focal point unit:Shandong Nanshu Graphite Mine

Proposing unit:National Building Materials Bureau Standardization Institute

Publishing department:State Bureau of Technical Supervision

competent authority:China Building Materials Industry Association

Introduction to standards:

This standard specifies the test method for testing the adhesion of graphite emulsions on picture tubes. This standard is applicable to the determination of the adhesion of graphite emulsions coated inside the cone of picture tubes, graphite emulsions on the neck of the tube, graphite emulsions coated outside the cone of picture tubes, and conductive graphite emulsions inside and outside the black-and-white picture tubes. GB/T 15064.4-1994 Test method for graphite emulsions on picture tubes Adhesion test method GB/T15064.4-1994 Standard download decompression password: www.bzxz.net

Some standard content:

National Standard of the People's Republic of China
Test method for graphite emulsion of kinescope
Test method for adhesion
Method for adherence of
colloidal graphite for kinescope1 Subject content and scope of application
This standard specifies the test method for detecting the adhesion of graphite emulsion of kinescope GB/T15064.4-94
This standard is applicable to the determination of the adhesion of graphite emulsion coated inside the cone of kinescope, graphite emulsion of tube neck, graphite emulsion coated outside, and conductive graphite emulsion inside and outside of black-and-white kinescope.
2 Reference standards
GB/T15064.1 Test method for graphite emulsion of kinescope Test method for solid content, volatile matter, ash content and pH value GB/T15064.3 Test method for resistivity of graphite emulsion of kinescope 3 Instruments and materials
a. Drying oven: working temperature 105~110℃b. Electric furnace: working temperature 450℃;bzxZ.net
c. Grid cutter: 11 cutting knives, grid cutter or blade with cutting interval of 1mm; d. Film thickness gauge: measuring range 0~2mm, graduation value 0.001mm; e. Glass slide: 76mm×26mm,
f. Adhesive tape: peeling force 6.9~7.0 Newton, width 25mm; g. Brush or writing brush.
4 Test steps
4.1 Preparation of test pieces
4.1.1 Preparation of test pieces of graphite emulsion coated inside cone of color picture tube, graphite emulsion on tube neck and conductive graphite emulsion inside black and white picture tube. 4.1.1.1 Take two microscope slides and wipe them clean with absorbent gauze. 4.1.1.2 Prepare the test pieces according to the provisions of Chapter 3 of GB/T15064.1. Use a brush or writing brush to evenly apply the mixed sample on the glass slide.
4.1.1.3 After the coating test piece is left to dry, put it in a drying oven at 105-110℃ for 30 minutes, then heat it in an electric furnace at 450℃ for 30 minutes, and then put it in a drying oven at 105-110℃ for 15 minutes, and take it out to cool naturally for 10 minutes. 4.1.2 The preparation of the test piece of graphite emulsion coated on the outside of the color picture tube and the conductive graphite emulsion coated on the outside of the black and white picture tube shall be made according to the steps of 4.1.2.1~~~4.1.2.4 in GB/T15064.3, and the drying time in the drying oven is 20 minutes. 4.1.3 Use a film thickness gauge to measure the coating thickness (accurate to 1um). The thickness of the dry coating should be 10-30μm, otherwise a new test piece should be made. 4.1.4 The graphite emulsion coated inside the cone of a color picture tube, the graphite emulsion coated on the neck of the tube, and the conductive graphite emulsion coated inside a black-and-white picture tube may also be prepared according to the steps of 4.1.1.1 to 4.1.1.6 in GB/T15064.3; the graphite emulsion coated outside a color picture tube and the conductive graphite emulsion coated outside a black-and-white picture tube may be prepared according to the steps of 4.1.2.1 to 4.1.2.5 in GB/T15064.3 (the drying time in the drying oven is 20 minutes). 4.2 Determination of adhesion rate
4.2.1 In the center of the coating surface of the test piece, use a grid marker or a blade to draw 11 lines horizontally and vertically, intersecting vertically, with a distance of 1mm between the lines, to draw 100 squares.
4.2.2 Gently stick the adhesive tape on the squares of the coating of the test piece, and roll it back and forth with a 2kg roller - times. 4.2.3 Pull one end of the tape at a 45° angle by hand, peel off the tape within 1s, record the number of squares peeled off, and stick the tape on the recording paper.
4.3 Calculation of results
4.3.1 The adhesion rate X (%) is calculated as follows:
X=100-n
Where: n-the number of squares transferred to the tape. 4.3.2 Take the arithmetic mean of the measured values ​​of the two test pieces as the test result. Additional Notes:
This standard was proposed by the Standardization Research Institute of the State Building Materials Bureau. This standard is under the jurisdiction of Shandong Nanshu Graphite Mine. This standard was drafted by Shandong Nanshu Graphite Mine and the Xianyang Non-metallic Mineral Research Institute of the State Building Materials Bureau. The main drafters of this standard are Liu Huidong, Yan Zaijin, Zhang Youyuan and Liu Youhong. 311
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.