title>HG/T 2064-1991 Technical requirements for filling volume measuring instruments - HG/T 2064-1991 - Chinese standardNet - bzxz.net
Home > HG > HG/T 2064-1991 Technical requirements for filling volume measuring instruments
HG/T 2064-1991 Technical requirements for filling volume measuring instruments

Basic Information

Standard ID: HG/T 2064-1991

Standard Name: Technical requirements for filling volume measuring instruments

Chinese Name: 装填体积测定仪技术条件

Standard category:Chemical industry standards (HG)

state:in force

Date of Release1991-07-06

Date of Implementation:1992-01-01

standard classification number

Standard ICS number:Chemical Technology>>71.120 Chemical Equipment

Standard Classification Number:Chemical Industry>>Chemical Machinery and Equipment>>G98 Chemical Industry Instruments

associated standards

Publication information

other information

Introduction to standards:

HG/T 2064-1991 Technical Specifications for Filling Volume Measuring Instruments HG/T2064-1991 Standard download decompression password: www.bzxz.net

Some standard content:

Chemical Industry Standard of the People's Republic of China
HG/T2064-91
Technical Conditions for Filling Volume Meters
Issued on July 6, 1991
Ministry of Chemical Industry of the People's Republic of China
Implementation on January 1, 1992
Chemical Industry Standard of the People's Republic of China
Technical Conditions for Filling Volume Meters
Subject Content and Scope of Application
This standard specifies the technical requirements, test methods and inspection rules for filling volume meters. This standard applies to the measuring instrument for measuring the filling volume and apparent density of color materials or physical materials. 2 Reference standards
ZBY002 Basic environmental conditions and test methods for transportation and storage of instruments and meters 3 Technical requirements
3.1 Working environment
Ambient temperature: 0~40℃;
b: Relative humidity: not more than 85%;
No corrosive and harmful impurities in the environment.
3.2 Appearance and structural requirements
HG/T 2064-
3.2.1 The instrument surface should not have obvious dents, scratches, cracks, deformations, etc. The surface coating should not bubble, crack or fall off, and the metal parts should not have rust and other mechanical damage. 3.2.2 The switch and button operation should be flexible and reliable. : 3.2.3. The text symbols and signs that describe the functions should be clear and correct. 3.3 Basic requirements
3.3.1 Volumetric cylinder: The capacity is 250ml, and the scale interval is 2ml. The total weight of the volumetric cylinder, fixed cover and base frame is: 670±45g. 3.3.2
Anvil installation position: The raised shaft should fall onto the anvil from 3±0.1mm away from the anvil. Approved by the Ministry of Chemical Industry of the People's Republic of China on July 6, 1991 and implemented on January 1, 1992
Small plane
HG/T2064-
Filling volume measuring instrument diagram
2-sleeve; 3-measuring cylinder; 4-rubber pad;
-cam:
5-measurement seat: 6-shaft; 7-anvil
3.4 ​​Main performance
HG/T2064-91
3.4.1 Number of vibrations of the seat per cycle: 1250±1 times. 3.4.2 Vibration frequency of the frame: 250±15 times/min.3.4.3 Repeatability: Under the same working conditions, the error of the vibration times of the frame in two cycles is ±1 time.3.5 Influence of power supply fluctuation
The filling volume meter can work normally under the power supply voltage of 220V±10%, 50Hz. 3.6 Insulation resistance
The insulation resistance between the power plug and the casing should not be less than 20MQ.3.7 Dielectric strength
The power plug and the casing should withstand 50.Hz1000V AC voltage for 1min, and there should be no breakdown and flying neck phenomenon.3.8 Transportation requirements
When transporting the filling volume meter, it should meet the requirements of ZBYO02. 4 Test method
4.1 Test conditions
Ambient temperature: 0~40℃
Ambient relative humidity: not more than 85%
4.2 Appearance
Visual inspection, the product should meet the requirements of Article 3.2, 4.3 Total weight of the measuring cylinder, fixed cover and frame
Check with a balance, it should meet the requirements of Article 3.3. 4.4 Anvil installation position
Check with a special plug gauge according to the attached drawing, at this time, the shaft should be at the highest position of the cam, and the position from plane A to the anvil should meet the requirements of Article 3.3.3.
4.5 Test of the number of vibrations per cycle of the frame
Install the photoelectric signal frame of the photoelectric counter on both sides of the frame, and make the instrument shield light once every vibration, turn on the power of the counter, and start the filling volume meter at the same time. When the instrument stops vibrating automatically, the counter shows the number of vibrations of the frame, which should meet the requirements of Article 3.4.1.
4.6 Vibration frequency test
Start the instrument and press the stopwatch at the same time. When the timer reaches 1 minute, press the stop button. The value displayed by this counter shall meet the requirements of Article 3.4.2.
4.7 Repeatability test
Under the same working conditions, perform vibration tests on the instrument twice according to the method in Article 4.5. The result shall meet the requirements of Article 3.4.3.
4.8 Power supply fluctuation influence test
During the test, first increase the power supply voltage from 220V to 242V suddenly, then reduce it to 220V, and then suddenly reduce it to 198V. The instrument shall be able to work normally.
4.9 Insulation resistance test
Use a 1.0-level megohmmeter to connect the power plug and the housing of the instrument, apply voltage, and wait for the megohmmeter reading to stabilize for 5s. The displayed value shall meet the requirements of Article 3.6.
4.10 Dielectric strength test
Use an adjustable power supply to feed the test voltage between the power plug and the housing, gradually increase it to 1000V within 5~10s and maintain it for 1min. The test result should meet the requirements of Article 3.7.
4.11 Transport test
HG/T2064-
The test conditions and methods shall be carried out in accordance with the requirements of ZBYO02. 5 Inspection rules
5.1 Product inspection is divided into factory inspection and type inspection. 5.1.1 Factory inspection
3.5, 3.6 inspections must be passed before the instrument can be shipped.
5.1.2 Type inspection
5.1.2.1 The quality inspection department of the manufacturer shall inspect the instrument according to 3.2, 3.3.2, 3.3.3, 3.4 of this standard. 3. 3, 3.4.
5.1.2.2 The instrument needs to be type-tested in the following cases: when the trial production of a new design prototype is completed;
when a new product is identified;
when there are major changes in the product design, process or components and materials used; d.
Products in normal production must be spot-checked once a year, and the number of spot-checked units shall not be less than 2; e.
when the national quality supervision agency proposes a requirement for type-testing. 3
3.8 Entry
5.2 Judgment rules
5.2.1 If there are unqualified items in the factory inspection instrument, it can be repaired once and re-inspected. If there are still unqualified items, the product is judged to be unqualified.
5.2.2 Type inspection is carried out on products that have passed the factory inspection. If one unit fails in the random inspection, it can be repaired once. If two units fail in the same item, the batch of products is judged to have failed the type inspection. 6 Marking, packaging, purchase and storagebzxZ.net
The instrument should be fixed with a nameplate, which should indicate: a.
Manufacturer name;
Name and model;
Product number:
Manufacturing date;
Power supply voltage.
6.2 Packaging and storage
The instrument should be packed in a plastic bag and fixed in the packaging box. 6.2.1
The packaging box should contain the following documents:
Product certificate;
Instruction manual;
Packing list.
6.2.3 The outside of the packaging box should be marked with words or symbols such as "Handle with care", "Moisture-proof", and "Do not invert". 6.2.4 Storage
The storage of instruments should comply with the requirements of ZBY002. Additional instructions:
This standard is proposed by China National Chemical Equipment Corporation, HG/T2064-
This standard is managed by the Technical Standardization Unit of Chemical Special Instruments of the Ministry of Chemical Industry. This standard was drafted by Guangxi Wuzhou Chemical Instrument Factory. The main drafter of this standard is Mai Baoxin.
People's Republic of China
Chemical Industry Standard
Technical Conditions for Filling Volume Meter
HG/T2064-91
Editor Chemical Industry Standards Department
(Standardization Research Institute of Ministry of Chemical Industry)
Postal Code: 100013
Printer Standardization Research Institute of Ministry of Chemical Industry
Copyright reserved. No reproduction allowed
Format 880×12301/16 Printing Sheet Word Count 9000 First Edition in September 1992
First Printing in October 1992
Print Quantity 1-300
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.