Basic Information

Standard ID: GB/T 15064.2-1994

Standard Name: Test method for graphite emulsion of picture tubes - Viscosity test method

Chinese Name: 显象管石墨乳试验方法 粘度试验方法

Standard category:National Standard (GB)

state:Abolished

Date of Release1994-04-18

Date of Implementation:1994-12-01

Date of Expiration:2009-04-01

standard classification number

Standard ICS number:Electrical Engineering >> 29.040 Insulating Fluids

Standard Classification Number:Building Materials>>Carbon Materials>>Q51 Graphite Materials

associated standards

alternative situation:Replaced by GB/T 15064-2008

Publication information

publishing house:China Standards Press

other information

Release date:1994-04-18

Review date:2004-10-14

drafter:Liu Huidong, Yan Zaijin, Zhang Youyuan, Liu Youhong

Drafting unit:Shandong Nanshu Graphite Mine and Xianyang Nonmetallic Mineral Research Institute of National Building Materials Bureau

Focal point unit:Shandong Nanshu Graphite Mine

Proposing unit:National Building Materials Bureau Standardization Institute

Publishing department:State Bureau of Technical Supervision

competent authority:China Building Materials Industry Association

Introduction to standards:

This standard specifies the test method for measuring the viscosity of graphite emulsions for picture tubes. This standard lists three viscosity test methods. It is suitable for measuring the viscosity of graphite emulsions for picture tubes for different purposes. GB/T 15064.2-1994 Test method for graphite emulsions for picture tubes Viscosity test method GB/T15064.2-1994 Standard download decompression password: www.bzxz.net

Some standard content:

National Standard of the People's Republic of China
Test method for viscosity of
colloldal graphite for kinescope1 Subject content and scope of application
This standard specifies the test method for detecting the viscosity of kinescope graphite emulsion. GB/T15064.2-94
This standard lists three viscosity test methods in parallel. It is suitable for measuring the viscosity of kinescope graphite emulsion for different purposes. 2 Reference standards
GB/T15064.1 Test method for graphite emulsion of picture tube Test method for solid content, volatile matter, ash content and pH value 3 Instruments and materials
a. Viscometer: rotational viscometer, measuring range 10~100000mPa*s, measuring error ±5%, b. Constant temperature water bath: working temperature 25±1℃; c. Rolling machine: speed 120±3r/min and 65±2r/min; d. Vibration machine: vibration frequency 190±2 times/min, amplitude 40mm; e. Thermometer,
f. Stopwatch;
g. n-octanol: chemically pure.
4 Determination of viscosity of graphite emulsions coated inside the cone of color picture tubes, graphite emulsions on tube necks, graphite emulsions on pins, and conductive graphite emulsions inside and outside black-and-white picture tubes
4.1 Sample preparation
Let the sample stand for more than 10 hours. In a constant temperature room at 25±1°C, mix the sample with a rolling machine according to the provisions of Chapter 3 of GB/T15064.1.
4.2 Test steps
4.2.1 After the sample stops rolling, immediately collect about 500g, place it in a beaker, place it under the viscometer, and measure the viscosity at a temperature of 25±1°C according to the conditions in Table 1. The preparation time from the sample stopping rolling to the start of the measurement under the viscometer is 120s. Approved by the State Bureau of Technical Supervision on April 18, 1994, 304
Implementation on December 1, 1994
Color picture tube
Black and white picture tube
Graphite emulsion coated inside the cone
Graphite emulsion on the pin
Graphite emulsion on the neck
Inner conductive graphite emulsion
Outer conductive graphite emulsion
GB/T15064.2--94
Rotor number
Speed, r/min
Selected by viscosity index and deviation range
Note: The viscosity measurement temperature of specific products of outer conductive graphite emulsion of black and white picture tubes can be specified as 20±1℃. Determination time, s
4.2.2 When the determination time is over, first press the pointer control lever to stop the pointer in the reading window, then turn off the motor, stop the rotation, and read the reading (the reading accuracy is 0.1 scale). Use a thermometer to measure and record the sample temperature. 4.2.3 After the first sampling, put the sample bottle back on the roller, roll it for 10 minutes, and then perform the second measurement according to the above steps. 4.3 Calculation of results
4.3.1 The viscosity of the graphite emulsion coated on the cone of a color picture tube and the graphite emulsion on the pins nt (mPa·s), the viscosity of the graphite emulsion on the neck of a color picture tube and the conductive graphite emulsion inside a black-and-white picture tube nz (mPa·s), and the viscosity of the conductive graphite emulsion outside a black-and-white picture tube n: (mPa·s) are calculated according to formula (1), formula (2) and formula (3) respectively:
n=reading×2-
72=reading×10
13-reading×K
Where: K is determined by the selected rotor and speed. (1)
4.3.2 The arithmetic mean of the two measurements is taken as the test result. The relative deviation of the two measured values ​​shall not exceed 2%. Otherwise, a third measurement shall be carried out and the test result shall be calculated based on the two measured values ​​that do not exceed the tolerance. 5 Determination of the viscosity of graphite emulsion coated on the outside of color picture tubes 5.1 Sample preparation
5.7.1 Let the sample stand for more than 10 hours. In a constant temperature room at 25±1℃, use a rolling machine to mix the sample according to the following conditions: rolling method: the peripheral direction of the sample bottle;
speed: 65±2r/min,
rolling time: 10h.
5.1.2 After the sample is rolled, immediately collect about 600mL and place it in a beaker. If there are many bubbles in the sample, 3mL of n-octanol should be added dropwise, and stirring with a sampling spoon for 1min to eliminate the bubbles in the sample. 5.2 Test steps
5.2.1 After the bubbles in the sample are eliminated, immediately place it under the viscometer and measure the viscosity according to the conditions in Table 2. Table 2
Rotor number
Speed, r/min
Measurement time, s
5.2.2 At the end of the measurement time, read the reading and record the sample temperature according to the provisions of 4.2.2. 5.2.3 After the first sampling, put the sample bottle back on the roller. After rolling for 10 minutes, perform the second measurement according to the steps of 5.1.2 to 5.2.2.
5.3 Result calculation
5.3.1 The viscosity n4 (mPa·s) of the graphite emulsion coated on the color picture tube is calculated according to formula (4): = reading × 10.
5.3.2 Calculate the test results according to 4.3.2.
6 Determination of viscosity of graphite emulsion in black matrix of color picture tube 6.1 Preparation of sample
GB/T15064.2-94
6.1.1 Let the sample stand for more than 10 hours, then soak it in a constant temperature water tank at 25±1℃ for 30 minutes, and adjust the sample temperature to 25±1℃. 6.1.2 In a constant temperature room at 25±1℃, use a vibrator to mix the sample according to the following conditions: Vibration mode: horizontal vibration;
times: 190±2 times/min;
width: 40mm,
vibration time: 30min
You can also use a small mixer to mix the sample at a speed of 800~1000r/min for 15 minutes. 6.2 Test stepsbZxz.net
6.2.1 After the sample is mixed, immediately collect about 500g, put it in a beaker, put it under the viscometer, and measure the viscosity according to the conditions in Table 3. The preparation time from the stop of the sample vibration (or stirring) to the start of the measurement under the viscometer is 60s. Table 3
Rotor number
Speed, r/min
6.2.2 At the end of the measurement time, read the reading according to 4.2.2 and record the sample temperature. Measurement time, s
6.2.3 After the first sampling, put the sample bottle back on the vibrator, vibrate for 1min (or stir it with a mixer for 1min), and then perform the second measurement according to the above steps.
6.3 Calculation of results
6.3.1 The viscosity s (mPa·s) of the black bottom graphite emulsion of the color picture tube is calculated according to formula (5): ns=reading×1
6.3.2 Calculate the test results according to 4.3.2.
Additional Notes:
This standard was proposed by the Standardization Research Institute of the State Building Materials Bureau. This standard is under the jurisdiction of Shandong Nanshu Graphite Mine. This standard was drafted by Shandong Nanshu Graphite Mine and the Weiyang Non-metallic Mineral Research Institute of the State Building Materials Bureau. The main drafters of this standard are Liu Huidong, Yan Zaijin, Zhang Youyuan and Liu Youhong. 306