title>JB/T 10441.1-2004 Corrugated insulating paper for electrical use Part 1: Definitions and general requirements - JB/T 10441.1-2004 - Chinese standardNet - bzxz.net
Home > JB > JB/T 10441.1-2004 Corrugated insulating paper for electrical use Part 1: Definitions and general requirements
JB/T 10441.1-2004 Corrugated insulating paper for electrical use Part 1: Definitions and general requirements
Basic Information
Standard ID:
JB/T 10441.1-2004
Standard Name: Corrugated insulating paper for electrical use Part 1: Definitions and general requirements
This part specifies the definition and general requirements of corrugated insulating paper for electrical use. This part applies to corrugated insulating paper for electrical use. JB/T 10441.1-2004 Corrugated insulating paper for electrical use Part 1: Definition and general requirements JB/T10441.1-2004 Standard download decompression password: www.bzxz.net
Some standard content:
ICS29.035.99 Machinery Industry Standard of the People's Republic of China JB/T10441.1-—2004 Crepe insulating papers for electrical purposes Part 1: Definitions and general requirements requirements(IEC60554-1:1977,MOD) Released on March 12, 2004 Implemented on August 1, 2004 Released by the National Development and Reform Commission of the People's Republic of ChinaForeword 2 Normative references 3 Terms and definitions… 4 Models, names and codes. General requirements Inspection rules Packaging, marking, transportation and storage JB/T10441.1—2004 JB/T10441.1-2004 JB/T10441 "Corrugated insulating paper for electrical use" is divided into three parts: Part 1: Definitions and general requirements; Part 2: Test methods: Part 3: Technical requirements. This part is the first part of JB/T 10441. This part modifies and adopts C60554-1 "Specification for fiber paper for electrical use Part 1: Definitions and general requirements" (English version of 1977). The relevant technical differences have been compiled into the text and marked with a vertical single line in the margin of the clauses they involve. The main differences between this part and IEC60554-1 are as follows: - The introduction of EC60554-1 is deleted, and the content of the standard structure in its introduction is incorporated into the preface of this part: - Added a chapter on "Normative Reference Documents"; - Deleted the clauses of [EC60554-1 that are not related to electrical crepe paper - Added the definition of electrical crepe paper; The code is compiled according to the requirements of JB/T2197 "Classification, naming and model compilation method of electrical insulating materials products", and refers to the code of EC60554-1 and the scope of EC60554-3: - Specificize the "supply conditions" of IEC60554-1: Some contents of IEC60554-3-3 are incorporated into this part. This part is proposed by China Machinery Industry Federation. This part is under the jurisdiction of the National Technical Committee for Standardization of Insulating Materials. Drafting unit of this part: Guilin Electric Science Research Institute. The main drafters of this part: Li Bingsong, Yan Xuemei. This part is formulated for the first time. 1 Scope Corrugated insulating paper for electrical use Part 1: Definitions and general requirements This part of JB/T10441 specifies the definitions and general requirements of corrugated insulating paper for electrical use. This part applies to corrugated insulating paper for electrical use. 2 Normative references JB/T10441.1--2004 The clauses in the following documents become the clauses of this part through reference in this part of JB/T10441. All subsequent amendments (excluding errata) or revisions of dated references are not applicable to this part. However, parties to an agreement based on this part are encouraged to study whether the latest versions of these documents can be used. For undated references, the latest versions apply to this part. JB/T2197-1996 Classification, naming and model compilation methods of electrical insulating materials products 3 Terms and definitions The following terms and definitions apply to this part. 3.1 Crepe insulating paper for electrical purposes is a crepe paper made of insulating kraft paper as the base material and processed by creping. There are two types: one is a hard crepe insulating paper with poor absorption made of low (L) or medium (M) air permeability insulating kraft paper as the base material; the other is a soft porous crepe insulating paper made of high (H) air permeability insulating kraft paper as the base material. Insulating kraft paper is a type of paper made entirely of softwood pulp obtained by the sulfate process. 3.3 Crepe paper Paper that has been creped. Creping The process of crumpling paper to improve its stretchability and softness. 3.5 Air permeability The average air flow rate passing through a unit area of a sample per unit time under the unit pressure difference between the two sides of the paper under specified test conditions. 3.6 substance Mass per unit area, expressed in grams per square meter (g/m2). 4 Model, name and code Electrical corrugated insulating paper is determined by the fiber product requirements in JB/T2197 and the characteristics of the base material used. The specifications are divided according to the thickness. The code includes the model, thickness specification, basis weight, elongation at break, number of corrugations and whether it is pressed. JB/T10441.1-2004 Example 1: Example 2: Corrugated insulating paper for electrical use A nominal thickness of 0.30 mm A fine wrinkle A post-pressing A percentage of elongation at break after wrinkling A certain value, in g/m It is widely used in low permeability (L≤0.05μm/Pas) or medium permeability (0.05μm/Pas0.5um/Pas) as the base paper to make L porous soft corrugated insulation paper Classifications specified in JB/T2197-1996 standard The preferred nominal values of elongation at break in the above examples are 20%, 30%, 50%, 80%, 120%, 200% and 300%: coarse, medium and fine indicate the number of wrinkles: "fine" means more than 12 per 10mm; "medium" means 8 to 12 per 10mm; "coarse" means less than 8 per 10mm: The recommended nominal thickness is 0.25mm, 0.30mm, 0.36mm, etc. 5 General requirements 5.1 Appearance Electrical corrugated paper is a roll paper. Any delivery of corrugated insulation paper should be tightly rolled (but the corrugated paper should not be stretched and deformed), with smooth ends, even wrinkles, easy to unroll, no adhesion, and no creases, damage, stains, pinholes, water marks, pulp blocks, impurities, etc. 5.2 Paper roll The outer diameter or weight of each piece of corrugated insulation paper shall be specified in Part 3 of this standard or negotiated by the supply and demand parties. Corrugated insulation paper should be wound on the tube core. The paper roll size, tube core requirements, and the number of paper sections should be specified in Part 3 of this standard or in the supply and demand contract. 5.3 Tube core Corrugated insulation paper should be wound on a hard tube core, and the tube core size is specified in Part 3 of this standard. 6 Inspection rules 6.1 Corrugated insulation paper shall be subject to factory inspection and type inspection. 6.2 The type inspection items are all the items specified in Part 3 of this standard, and shall be carried out at least once every three months. When the raw materials or process conditions are changed, type inspection should also be carried out. 2 JB/T10441.1—2004 6.3 The batch basis, single sample method and factory inspection items of products are specified in Part 3 of this standard. Each batch of corrugated insulation paper shall be subject to factory inspection, and the products can be shipped only after passing the inspection 6.4 When any of the inspection results does not meet the performance requirements, one group shall be taken from each of the other two rolls of the batch of products and the test shall be repeated. If one group still does not meet the requirements, the batch of products shall be unqualified. 6.5 The user unit may conduct acceptance inspection according to all or part of the items specified in Part 3 of this standard. 7 Packaging, marking, transportation and storage 7.1 Packaging Corrugated insulation paper rolls shall be packaged with moisture-proof paper or plastic film, covered with plastic bags on the outside, sealed and packed in packaging boxes, and attached with product certificates. 7.2 Markingbzxz.net The packaging box of corrugated insulation paper shall be clearly and firmly marked with the manufacturer's name and product name, code, batch number, net weight, gross weight, production date, and moisture-proof, fire-proof, heat-proof, vibration-proof and other marks. 7.3 Storage Corrugated insulation paper shall be stored in a dry and clean room and shall not be placed near fire or heat sources or exposed to direct sunlight. The storage period of corrugated insulation paper is specified in Part 3 of this standard. Products that have exceeded the storage period can still be used after inspection and are qualified. 7.4 Transportation Corrugated insulation paper shall be protected from moisture, fire, heat and extrusion during transportation. People's Republic of China Mechanical Industry Standard Corrugated Insulating Paper for Electrical Use Part 1: Definitions and General Requirements JB/T10441.1--2004 Published and distributed by Machinery Industry Press No. 22, Baiwanzhuang Street, Beijing Postal Code: 100037 Format: 890mm×1240mm 1/16· 0.5 printing sheet·11,000 words 1st edition, 1st printing, August 2004 Book number: 15111: 7351 Website: http:/cmpbook.com Editorial office phone: (010) 88379779 Direct sales center phone: (010 88379693 All books without anti-counterfeiting labels on the cover are pirated Infringements will be investigated Copyright reserved Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.