This standard specifies the verification items and technical requirements, verification instruments, verification force and method, verification results and treatment of enameled round wire quick break tester. This standard applies to the verification of enameled round wire quick break tester. JB/T 4279.5-1994 Verification method of enameled winding wire test equipment Quick break tester JB/T4279.5-1994 Standard download decompression password: www.bzxz.net
Some standard content:
Mechanical Industry Standard of the People's Republic of China Verification Method of Enameled Winding Wire Test Instrument and Equipment Snap-Tear Tester 1 Subject Content and Scope of Application JB/T4279.5-94bZxz.net Replaces JB4279.5-86 This standard specifies the verification items and technical requirements, verification instruments, verification methods, verification results and processing of enameled round wire snap-tear tester. This standard is applicable to the verification of enameled round wire snap-tear tester. 2 Reference Standards JB/T4279.1 General Rules for Verification Method of Enameled Winding Wire Test Instrument and Equipment 3 Verification Items and Technical Requirements 3.1 The starting distance between the two clamps should be 250±1mm. 3.2 When pulling the specimen quickly, there should be no slipping and movement. 3.3 The quick pulling speed should be greater than 2m/s. 4 Calibration instruments 4.1 Vernier caliper, 300mm, graduation value 0.02mm; or steel tape measure. Q-1 Enameled wire test instrument detector. 5 Calibration method Use a vernier caliper to measure the starting distance between the two tools. 5.1 5.2 Use samples with nominal conductor diameters of 0.05mm and 1.0mm to conduct a quick pull test and check whether the samples have any slipping or movement. 5.3 Determine the quick pull speed. The measurement is carried out when the tester is unloaded (without samples). 5.3.1 Measure the quick pull speed Fix a 10±0.1mm wide metal sheet on a movable fixture. During the quick pull, while the metal sheet is exposed to light, a pulse signal is output through a photoelectric controller. The number of pulses n is determined by the Q-1 Enameled wire test instrument detector. b. Measure three times at the starting, middle and end positions of the movable fixture's moving stroke. 5.3.3 Calculate the quick pull speed Calculate the quick pull speed for each measurement at each measuring position: Where; V quick pull speed, m/s; V1000/n Q-1 enameled wire tester reading. b. Calculate the average of the three calculated values at each measuring position; c. Take the maximum value of the three average values for the quick pull speed. 5.3.4 Care should be taken to avoid the counting error of the Q-1 enameled wire tester due to electrical interference during measurement. Approved by the Ministry of Machinery Industry on December 9, 1994 Implemented on June 1, 1995 Handling of verification results JB/T4279.5-94 6.1 A verification certificate shall be issued to qualified enameled round wire quick break testers, and a verification result notice shall be issued to unqualified ones. The cover forms of the verification certificate and verification result notice are shown in the appendix of JB/T4279.1. 6.2 The verification cycle of enameled round wire quick break testers is generally set at 2 years. Additional remarks: This standard was proposed and managed by the Shanghai Cable Research Institute of the Ministry of Machinery Industry. This standard was drafted by the Shanghai Cable Research Institute of the Ministry of Machinery Industry and others. The main drafter of this standard is Zhu Bing. Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.