title>Chemicals - Water solubility test - GB/T 21845-2008 - Chinese standardNet - bzxz.net
Home > GB > Chemicals - Water solubility test
Chemicals - Water solubility test

Basic Information

Standard ID: GB/T 21845-2008

Standard Name:Chemicals - Water solubility test

Chinese Name: 化学品 水溶解度试验

Standard category:National Standard (GB)

state:in force

Date of Release2008-05-12

Date of Implementation:2008-09-01

standard classification number

Standard ICS number:Environmental protection, health care and safety >> 13.300 Dangerous goods protection

Standard Classification Number:Comprehensive>>Marking, packaging, transportation, storage>>A80 Marking, packaging, transportation, storage Comprehensive

associated standards

Procurement status:IDT OECD No.105:1995

Publication information

publishing house:China Standards Press

ISBN:155066·1-32501

Plan number:20075188-T-469

Publication date:2008-08-01

other information

Release date:2008-05-12

drafter:Zhou Xin, Chen Huiming, Wang Junbing, Yu Wenlian, Wang Lifeng, Hao Nan, Sun Xin, Wang Zheng

Drafting unit:China Institute of Inspection and Quarantine

Focal point unit:National Technical Committee on Hazardous Chemicals Management Standardization

Proposing unit:National Technical Committee on Hazardous Chemicals Management Standardization (SAC/TC 251)

Publishing department:General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China National Standardization Administration

competent authority:National Standardization Administration

Introduction to standards:

This standard specifies the scope, definition and units, reference materials, test methods, data and reports of water solubility test of chemicals. This standard is applicable to the determination of water solubility of chemicals. GB/T 21845-2008 Water solubility test of chemicals GB/T21845-2008 Standard download decompression password: www.bzxz.net
This standard specifies the scope, definition and units, reference materials, test methods, data and reports of water solubility test of chemicals. This standard is applicable to the determination of water solubility of chemicals.
This standard is equivalent to the Organization for Economic Cooperation and Development (OECD) Chemical Testing Guide 105 (1995) "Water Solubility" (English version).
This standard has made the following editorial changes:
--- Added the scope part;
--- Changed the measurement unit to the legal measurement unit of China.
This standard is proposed and managed by the National Technical Committee for Standardization of Hazardous Chemicals Management (SAC/TC251). || tt||
The responsible drafting organization of this standard is China Institute of Inspection and Quarantine.
The main drafters of this standard are Zhou Xin, Chen Huiming, Wang Junbing, Yu Wenlian, Wang Lifeng, Hao Nan, Sun Xin and Wang Zheng.
This standard is published for the first time.
This standard is a revised version of the original OECD 105 method from 1981. There is no difference between the new version and the 1981 version in terms of chemical substances. The main format has been changed. This version is also based on the EC method "Water Solubility" [1] with some modifications.
The water solubility of a substance is greatly affected by impurities. This method is used to determine the water solubility of a pure substance that is
stable in water and not volatile. Before determining the water solubility, it is helpful to obtain some preliminary information about the compound, such as the structural formula, vapor pressure, dissociation constant and hydrolysis ability under pH conditions.
This standard introduces two methods: column elution method and flask method. In this standard, they are respectively applicable to chemicals with solubility less than and greater than 10-2g/L. This standard also introduces a simple pre-test. When the final step of the pre-test is carried out, the amount of sample used is rough, and it takes a certain amount of time for the solution to reach saturation.

Some standard content:

ICS13.300
National Standard of the People's Republic of China
GB/T 21845—2008
Chemicals
Water soluhility test
Chemicals-Water soluhility testIssued on 2008-05-12
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China Administration of Standardization of the People's Republic of China
Minquer Preventive
ht
Implementation on 2008-09-01bzxZ.net
GB/T 21845—2008
This standard is equivalent to the Organization for Economic Cooperation and Development (OECD) Chemical Testing Guide 105 (1995) "Water Solubility" (English version). This standard has been revised as follows:
Added the scope part;
Changed the measurement unit to the legal measurement unit of my country: This standard was proposed and managed by the National Technical Committee for the Administration of Hazardous Chemicals (SAC/TC251). The responsible drafting unit of this standard: China Institute of Inspection and Quarantine. The main drafters of this standard: Zhou Xin, Chen Huiming, Wang Junbing, Yu Wenlian, Wang Lifeng, Hao Nan, Sun Xin, Yu Feng This standard is published for the first time.
http://foodmate.neGB/T218452008
OECD Introduction
This standard is a revised version of the original OECD 105 method of 1981. There is no difference between the new version and the 1981 version in terms of chemical substances. The main format has been changed. This version is also based on the EC method "Water Solubility" [1]. The water solubility of a substance is greatly affected by impurities. This method is a method for determining the water solubility of a pure substance, which must be stable and non-volatile in water. Before determining the water solubility, it is helpful to obtain some preliminary information about the compound, such as the structural formula, vapor pressure, dissociation constant and hydrolysis ability under pH conditions. This standard introduces two methods: column elution method and flask method. In this standard, they are respectively applicable to chemicals with solubility less than and greater than 10'g/L. This standard also introduces a simple preliminary test. When the preliminary test is carried out in the last step, the amount of sample used is rough, and a certain amount of time is required for the solution to reach saturation. Partner double ht
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.