JB/T 2001.52-1999 Columnar accumulator tank for water system pump station (PN=20MPa)

Basic Information

Standard ID: JB/T 2001.52-1999

Standard Name: Columnar accumulator tank for water system pump station (PN=20MPa)

Chinese Name: 水系统 泵站用柱形蓄势器水罐(PN=20MPa)

Standard category:Machinery Industry Standard (JB)

state:in force

Date of Release1999-06-28

Date of Implementation:2000-01-01

standard classification number

Standard ICS number:Fluid systems and general parts >> 23.100 Fluid power systems

Standard Classification Number:Machinery>>General Parts>>J20 Hydraulic and Pneumatic Devices

associated standards

alternative situation:JB 2055-1984

Publication information

other information

Focal point unit:Metallurgical Equipment Standardization Technical Committee

Introduction to standards:

JB/T 2001.52-1999 JB/T 2001.52-1999 Columnar accumulator tank for water system pumping station (PN=20MPa) JB/T2001.52-1999 Standard download decompression password: www.bzxz.net

Some standard content:

IC.s$ 23.110
Machinery Industry Standard of the People's Republic of China
JB/T 2001.1~2001.74—1999
Water system assembly and parts1999-06-28 Issued
State Bureau of Machinery Industry
2(-01-U1 Implementation
1 Scope
Machinery Industry Standard of the People's Republic of China
Water system·Columnar accumulator water tank for pump station Watersyatem-Watersylindricalaccomulalor( PN=20 MIPa ]
This standard specifies the type, size and technical requirements of the water filter at the end of the formwork. JB/T2001.52-1999
2055-4
This standard is suitable for the use of cylindrical water filter for station with a nominal pressure of 2UMPa and water and air as the medium: 2 Type and size
1.14 A: Type and size of high voltage generator water tanks shall be as shown in Figure 1 and Table 1. The width of the single channel opening shall be 12mm1 and the lower channel shall be designed or shaped as needed to maximize the maintenance space. 2.2 Type B: Type and size of low voltage generator water tanks shall be as shown in Figure 2 and Table 2. Applicable to all overhead auxiliary units in the recording station area. 2.3 Type A and B water tanks shall be connected in multiple dimensions as shown in Figure 3. 3 Technical requirements
3.1 The air inlet shall be provided with an anti-collision plate that guides the air upward to prevent the air from rushing to the water level. Indicator port, affecting the accuracy of water barrier indication, 3.2 Except for the specially designed protruding potential pole, the body shall not be connected to other objects. 3.3 Due to the reasons of workmanship and material, different manufacturers have different wall thicknesses. The strength is guaranteed to be fully made under 20MPa. 1 Marking example
High support type A support device water energy:
Shape water lift (A type: 4mJB/T200L.52 [999 National Machinery Industry Bureau 1999-16-28 approved
2000-11-0! Demonstration bzxZ.net
Figure 1 A type
JBT 2001.52—1999
According to the request 1:
JBT2001.521949
Figure 3 A type, B type water trip external standard connection scale