title>JB/T 8163-1999 DC motors for auxiliary drives of rolling mills - JB/T 8163-1999 - Chinese standardNet - bzxz.net
Home > JB > JB/T 8163-1999 DC motors for auxiliary drives of rolling mills
JB/T 8163-1999 DC motors for auxiliary drives of rolling mills

Basic Information

Standard ID: JB/T 8163-1999

Standard Name: DC motors for auxiliary drives of rolling mills

Chinese Name: 轧机辅传动直流电动机

Standard category:Machinery Industry Standard (JB)

state:in force

Date of Release1999-08-06

Date of Implementation:2000-01-01

standard classification number

Standard Classification Number:Electrical Engineering>>Rotary Motors>>K23 DC Motors

associated standards

alternative situation:JB/T 8163-1995

Procurement status:IEC 60034-13 NEQ

Publication information

publishing house:Mechanical Industry Press

Publication date:2000-01-01

other information

drafter:Shih Shih-yin, Tam Yiu-ting, Wong Kit-man, Wong Hong-ling

Drafting unit:Shanghai Electric Science Research Institute, Shanghai Electric Motor Factory, Harbin Electric Motor Factory, Shanghai Nanyang Electric Motor Factory

Focal point unit:National Technical Committee for Standardization of Rotating Electrical Machines

Proposing unit:National Technical Committee for Standardization of Rotating Electrical Machines

Introduction to standards:

This standard applies to DC motors for auxiliary drives of rolling mills (hereinafter referred to as motors), and also applies to DC motors for lifting. This standard specifies the mechanical and electrical requirements and installation dimensions for motors installed on the bottom for heavy work. JB/T 8163-1999 DC motors for auxiliary drives of rolling mills JB/T8163-1999 Standard download decompression password: www.bzxz.net

Some standard content:

Mechanical Industry Standard of the People's Republic of China
JB/T8163
1999-08-06
Wa Xian Ji Dong
2000-01-01
JB/T8163
This standard is a revision of JB/T816395 "Auxiliary Drive DC Motor for Rolling Mill". Except for the modification of the numbering format according to the provisions of GB/T1, only one technical content has been modified. In Table 3, the original standard lists the moment of inertia GD, which is now changed to TEC60034-13. The moment of inertia I, its value is the maximum value specified by EC. This standard replaces TB/T8163-95 from the date of implementation. This standard is proposed and managed by the Jinguo Rotating Electric Machine Standardization Technical Committee! This standard is drafted by Shanghai Electric Science Research Institute, Shanghai Electric Machine Factory, Harbin Electric Machine Factory, and Shanghai Nanyang Electric Machine Factory. The main drafters of this standard are! Shi Shi, Tan Yaoting, Wang Jiemin, Huang Kangling. 1
JB/T81631999
JB/T816395
This standard applies to auxiliary drive DC motors for rolling mills (hereinafter referred to as motors), and is also applicable to DC motors for lifting. This standard specifies the mechanical and electrical requirements and installation dimensions for the motors installed on the bottom for heavy work. 2 Referenced standards
The provisions contained in the following standards constitute the provisions of this standard through reference in this standard. At the time of publication of the standard, the versions shown are valid. All standards will be revised, and the parties using this standard should explore the possibility of using the latest versions of the following standards. GB 191—1990
GB/T 755—1987
GB/T 997--1981
GB/T 1311—1989
GB 1971-—1980
GiB/T 1993—1993
Packaging, storage and transportation pictorial markings
Basic technical requirements for rotating electrical machines
Motor structure and installation type code
Test methods for DC motors
Motor line terminal markings and rotation direction
Cooling methods for DC motors (nenJFC60034—6:1991)GB/T 4942.1—1985
External protection level of motor
3 Terms
3.1 Maximum starting torque
The maximum value of the torque generated by the sudden flow of current into the motor at the moment of starting. 3.2 Maximum operating torque
The maximum value of the torque that can be generated during the operation of the motor. 4 Types, basic parameters and dimensions
4.1 External protection level
The external protection level of the motor is IP44. If the user has requirements, IP23 motors can also be supplied (see GB/T4942.1). 4.2 Cooling method
a) The motor adopts any of the following types of shell cooling methods: Fully enclosed motor includes natural cooling of the motor shell surface IC40 and air cooling of the motor interior IC410 driven by the internal fan driven by itself (GB/T1993)
h) Externally ventilated motor
includes natural air outlet with duct protection 17; duct air inlet duct outlet 37. If the user needs, the motor equipped with independent fan [C06] can also be supplied (see GB/T1993)
2000-01-01
JB/T8163
Fully enclosed and externally ventilated motors should be interchangeable by adding or removing appropriate covers and blowers. When changing the fully enclosed type to the externally ventilated type or vice versa, it is allowed to remove or install the internal fan. 4.3 Structural Installation Type
The structural installation type of the motor is IM1004 (see GB/T997), the motor shaft is horizontal, the motor foot is downward, and there are two round chain-shaped shaft extensions.
4.4 Installation Dimensions
The installation dimensions and tolerances of the motor shall be in accordance with the provisions of Figure 1 and Table 1. If the tolerances are not specified in the installation dimensions, the taper of the motor shaft extension is 1:10 according to GB/T4772.1. When the user requires the shaft extension to be 1:9.6 or the LC size changes, it can be agreed with the manufacturer separately:
The shaft extension at the drive end of the motor shall be equipped with a shaft extension chain, a locking washer and a nut, and the shaft extension at the drive end (usually the commutator end) shall be equipped with a protective cover.
The size of the shaft and key shall comply with the provisions of Table 2. LC
4 Bolt xH Random &
Note: The user can negotiate with the manufacturer for tolerance requirements on AB and N. 2
Explosion detection hole & A
Dimension 1.10
Figure 1 Motor installation outline diagram (This figure does not represent any product of the manufacturer) 2
* The lead wire of the motor is only for the case where the junction box is not installed. B
Each base leads the motor size
The side of the air duct
Motor lead wire
JB/T8163
Probability number
* Non-standard thread length, keep X Deng G (see Table 1) size, 4.5 Rated voltage of the electric peach
JB/T8163
Each base number Motor shaft extension size
The sawing degree is 1:10 The rated voltage of the motor is 220, 440V. If the user needs other rated voltages, the motor can be negotiated with the manufacturer. 4.6 Excitation mode and dynamic magnet voltage of the motor The excitation modes of the motor include series excitation, compound excitation, parallel excitation and external excitation. The rated voltage of the dynamic magnet winding of the externally excited motor is 220V or 110V. 4.7 Rated value of motors of various frame sizes The rated voltage of motors of various frame sizes shall comply with the provisions of Table 3. When the motor is powered by a DC power supply with no obvious pulsation (using a rotating generator as the power supply) for testing, it shall meet the temperature rise requirements specified in Table 3.3. Motors with a rated voltage of 220V shall be able to operate at 500V and below. The maximum operating voltage of motors with other rated voltages shall be agreed upon by the user and the manufacturer. When the operating voltage of the motor is higher than the above rated voltage, the rated operating torque specified in Table 3 is allowed to be reduced. The externally ventilated motor shall be able to output the specified rated power when the through-flow airflow is provided as specified in Table 3. The cooling air shall enter the motor from any air outlet.
The motor shall be able to operate at the maximum safe operating speed specified in Table 3 without damage. The moment of inertia (J) indicated by mr2 (m-mass disk; m=mean radius of the rotating body) shall not exceed the corresponding value given in Table 3. 5 Technical requirements
5.1 Ambient temperature and altitude
The motor shall be able to operate normally when the ambient temperature is between -30℃ and +40℃ and the altitude does not exceed 1000m. 5.2 Motor powered by rectifier power supply
When powered by a variable voltage rectifier power supply (i.e., thyristor converter), The motor is running at the rated auxiliary output specified in Table 3. At this time, the pulsation of the rectifier power supply does not exceed the pulsation component generated by the three-phase 50Hz, six controllable pulses (the main pulse frequency is 300 or 600Hz) and 4
JB/T81631999
when the AC line voltage is 400V and the DC average voltage is 440V. When the rectifier power supply is connected to a three-phase full-bridge line, the motor can be used without a smoothing reactor. Note: If the pulsation component of the rectifier power supply used by the motor exceeds the above provisions, its performance The performance of the DC power supply with the same grid voltage RMS value may be very different. Under the same rated load, the motor's resistance, speed regulation, shaft current and noise may increase, and the commutation may deteriorate. The degree of difference will depend on the size of the pulsating current in the motor circuit, and the fewer the rectifier pulses and the larger the phase control mouse, the greater the difference.
5.3 Wet rise
The motor adopts a lower insulation structure:
When the motor is running at rated output power and specified working system, and its ambient temperature does not exceed 40℃, any The temperature rise of any winding should not exceed 75K when measured by the thermometer method or 110K when measured by the resistance method. The temperature rise of the commutator should not exceed 85K when measured by the thermometer. The temperature rise of other parts such as the armature core, the resistor, the brush holder, the pole tip, etc. should not lead to a reduction in the motor's operating performance and service life.
The temperature rise of the motor can be measured by the resistance method or the thermometer method to see if it meets the requirements of this standard. The temperature rise test of the short-time working (S2) motor should be started when the difference between the temperature of the motor windings and other parts and the ambient temperature is no more than ±5K. 5.4 Heating of excitation windings at rest
The temperature rise of the separately (parallel) excited windings of separately (parallel) excited or compound excited motors (S31 system) at rest under continuous rated excitation current shall not exceed the provisions of 5.3.
5.5 Speed ​​adjustment rate
5.35.1 Speed ​​regulating motors
For fully enclosed motors with 1h rating or externally ventilated motors with continuous rating, the reverse rotation adjustment rate shall not exceed the values ​​in Table 4. 9
Ventilated continuous practice quota or full-injection closed short-time working system (≤2 [fixed voltage], tmin
8594.3,75900
H0252050
Fully enclosed type
excited short-time working
30min quotawww.bzxz.net
1029:203350
911800 900-1803 | | tt | 50
4521200
B00/2000
725:1 450
650rL.500
575:1130
550-1:00
S15/1050
200:1000
812 There are 3 sizes of motors, the motor installation size is ten equalizing valves, the load micro design is different, in order to adjust the motor speed range, the minimum allowable winding is used. 2)
Intermittent cycle working system (S3) Each period is 5 nin, and the excitation is static. The rated value of each motor (220, 440) Fully enclosed test period continuous cycle working system
Negative wheel holding rate 30%
4) Maximum starting and maximum suitable for the maximum value of the performance specified by the test motor. 5.5.2 Compound motor JB/T81631999 Maximum turn-on adjustment rate (%) For fully enclosed motors with a rated value or externally ventilated motors with a continuous rated value, the excitation Ampere ratio is about 50, that is, parallel excitation (or compensation excitation) Ampere turns 50, and series excitation turns (the number of series excitation turns is the nearest integer) 5.6 Speed ​​change due to heat generation During the specified operating period, the speed change from cold full load to hot full load, the speed change of fully enclosed motors should be Not more than 20% of the rated rotation speed: H of an externally ventilated motor should not exceed 15% of the rated speed. 5.7 Rated speed tolerance
Under normal operating temperature, rated load, rated voltage and rated brush current, the speed tolerance of the motor is ±7.5% of the rated speed.
5.8 Lead wire or terminal box
The position of the lead wire or terminal box of the motor should be on the side of the motor when viewed from the transmission end (i.e. non-commutator end). When the motor has a terminal box, the axial position of the terminal box is offset from the center line and close to the commutator end. When there is no terminal box, the relevant dimensions of the lead wire are shown in Table 1. 5.9 Rotational direction
The motor should be able to run in any direction,
5.10 Axial motion of the armature
The axial motion of the armature shall not exceed 5 m. 5.11 Others
Any requirements not specified in this standard shall comply with the provisions of GB755: 6 Inspection rules
6.1 Each motor must be inspected and qualified before use! , and a product inspection certificate shall be attached. 6.2 Test items and test methods of motors: The test items of motors shall comply with the provisions of GR/T755, and the test methods shall comply with the provisions of GB/T1311, but the following provisions shall be followed when conducting the various tests:
a) Rated load test: The test time for continuous rated and intermittent cycle duty motors is 1h. For intermittent cycle duty motors, rated load tests shall be carried out according to the short-duty duty system. The test time for short-duty duty motors is the time of the short-duty duty system. Rated load test b) Short-time over-torque test: The test time is 15s, and the torque value is in accordance with the specifications of the maximum operating torque in Table 3. The commutation spark level should not exceed 2 levels;
) The motor should be able to withstand a short-time increased voltage test under no load. The test voltage is 130% of the rated voltage, but should not be less than 600V. The test time is 3min without failure; JB/T8163
d) The insulation dielectric strength test of the motor winding to the casing and between the windings: The test voltage of the motor is 2000V and the test time is 1 min.
7 Marking and packaging
7.1 Nameplate marking
The nameplate should have the following markings:
a) Motor name:
b) Manufacturer's name:
|) Year of manufacture or code included in the product number:
d) Manufacturer's product number;
e) Manufacturer's product model mark;
Frame number mark and shaft extension taper (may not be marked when the taper is 1:10);
h) Rated voltage and "DC" mark:
1) Rated power;
i) Working system code and time Or continuous rate: k) Rated speed:
D) Maximum safe speed:
m) Rated current:
) Excitation mode (shunt excitation, compound excitation, series excitation or external excitation): 0) Rated excitation voltage and rated excitation current: P) Insulation grade;
) Motor quantity, kx;
T) Shell protection grade:
3) Air flow and wind pressure of external ventilation continuous rated motor. 7.2 Lead wire marking
The terminal marking and arrangement of the lead wire shall be in accordance with the provisions of Table 5 (see B191). Table 5 Terminal arrangement and marking
Machine frame number
802 --818
Winding name
Armature winding
Compensating cable group
Internal pole replacement winding
Series-break winding
Shunt-excited winding
Separately excited burning group
Outgoing line terminal arrangement
ED Ar(or B,?
E, DB (or A)
Outlet terminal mark
Commutator end
JB/T8163
3The motor packaging should be able to ensure that under normal storage and transportation conditions, it will not be damp and damaged due to poor packaging within 1 year from the time of shipment.
The text and logo on the outer wall of the packaging box
The text and logo on the outer wall of the packaging box should be neat and clear, and the content is as follows: a) Shipping station and name:
b) Receiving station and receiving unit name;
c) Motor model and factory number: ||tt| |d) Net weight of the motor and gross weight of the box; e) Box size:
) The words "handle with care" and "keep away from moisture" should be marked on the outside of the box, and the graphics should comply with the provisions of GB191. 9
JB/T8163
Yanhang880b1230
19XXXXling
100044
WanduanX/X
MatricesxXX,XXX
19XX CollectionXX Cabin
德pxXX.XX Wing
极藕亥2033 5 0
911800 900-1803
900/1200900-1809
650650
725/1800
6541950
575/E733
550F1550
5151300
5591250
4521200
B00/200 0
725:1450
650rL.500
575:1130
550-1:00
S15/1050
200: 1000
812 motor has 3 sizes, motor installation size and equalizing valve, different design, in order to adjust the motor speed range, the minimum allowable process setting toilet 2)
intermittent cycle operation (S3) each sector period is 5 nin, and the excitation is statically connected to the paste. Rated value of motors of various frame numbers (220, 440) Fully enclosed test period continuous cycle duty
Negative wheel holding rate 30%
4) Maximum starting load Maximum suitable running load The maximum value that can be achieved by the performance specification. 5. The maximum sleep value cannot be used to calculate the maximum starting torque. The maximum running torque # is updated. tt||JB/T8163
Basic speed (%)
5.5.2 Compound motor
JB/T81631999
Maximum transfer adjustment rate ()||tt ||】h rated fully enclosed motor or continuous rated external ventilated motor, the excitation Ampere ratio is about 50, parallel excitation (or compensation excitation) Ampere turns 50, series excitation turns (series excitation turns number is close to 5.6 Due to the change in speed caused by heating tj
During the specified operating period, the speed changes from cold full load to hot full load, and the speed changes of fully enclosed motors should be No more than 20% of the rated rotational speed: H of an externally ventilated motor shall not exceed 15% of the rated speed 5.7 Rated speed tolerance
Under normal operating temperature, rated load, rated voltage and rated brush current, The speed tolerance of the motor is ±7.5% of the rated speed.
5.8 Lead wire or terminal box
The location of the lead wire or terminal box of the motor, from the transmission end (i.e. non-commutator end) Look at the motor side. When the motor has a junction box, the axial position of the junction box is offset from the center line and close to the commutator end. When there is no junction box, the relevant dimensions of the lead wire are shown in Table 1. 5.9 Rotational space | |tt||The motor should be able to run in any direction.
5.10 Axial motion of the armature
The axial motion of the armature shall not exceed 5 m. 5.11 Others
Any requirements not specified in this standard shall comply with the provisions of GB755: 6 Inspection rules
6.1 Each motor must be inspected and qualified before it can be used! , and a product 6.2 Test items and test methods for motors: The test items for motors shall be in accordance with the provisions of GR/T755, and the test methods shall be in accordance with the provisions of GB/T1311, but the following provisions shall be followed when conducting the tests such as F: || tt||a) Rated load test: The test time for continuous rated and intermittent cycle duty motors is 1h. For intermittent cycle duty motors, the rated load test should be carried out according to the 11-hour short-duty duty system. The test time is the short-time working time. After the commutation check: When the motor is from no load to rated load and from base speed to high speed (including the reverse when weakening the magnetic field or increasing the output pressure), the commutation spark level should not b) Short-time over-torque test: the test time is 15s, the torque value is in accordance with the maximum operating torque in Table 3, and the switching level should not exceed level 2; ||tt| |) The motor should be able to withstand a short-term elevated voltage test in the empty state, the test voltage is 130% of the rated voltage, but should not be less than 600V, the test time is 3min, and no failure occurs; JB/T8163||tt| |d Test on insulation dielectric strength between motor windings and casing and between windings: The test voltage of the motor is 2000V and the test time is 1 min.
7 Marking and packaging
7.1 Nameplate marking
The nameplate should have the following markings:
a) Motor name:
b) Manufacturer Name:
) Year of manufacture or code included in the product number: d) Product number of the manufacturer;
e) Product model mark of the manufacturer;
Frame number mark and shaft extension taper (not required when the taper is 1:10)) Standard number and year;
h) Rated voltage and "DC" mark:
1) Rated power ;
i) Working system code and time or duration: k) Rated speed:
D) Maximum safe speed:
m) Rated current:
) Excitation mode (shunt excitation, compound excitation, series excitation or external excitation) ): 0) Rated excitation voltage and rated excitation current: P) Insulation grade;
) Motor quantity, kx;
T) Shell protection grade:
3) External ventilation 7.2 Marking of lead wires
The marking and arrangement of the lead wire terminals shall be in accordance with the provisions of Table 5 (see B191). Table 5 Arrangement and marking of lead wire terminals ||tt ||Frame No.
802 --818
Winding name
Armature winding
Compensating cable group
Internal pole replacement winding
Series-break winding
Parallel excitation Winding
External excitation group
Outlet terminal arrangement
ED Ar(or B,?
E, DB (or A)
Outlet terminal mark
Commutator end
JB/T8163
3The packaging of the motor should ensure that under normal storage and transportation conditions, The goods will not be damp or damaged due to improper packaging within one year from the date of shipment. The words and logos on the outer wall of the packaging box will not be damaged due to improper packaging. The markings should be clear and neat, including the following: a) Shipping station and name:
b) Receiving station and receiving unit name;
c) Motor model and factory number: ||tt| |d) Net weight of the motor and gross weight of the box; e) Box size:
) The words "handle with care" and "keep away from moisture" should be marked on the outside of the box. The graphics should comply with the provisions of GB191. 9
JB/T8163
Yanhang880b1230
19XXXXling
100044||tt| |万段X/X
Matrices xXX,XXX
19XX collection XX cabin
Germany pxXX.XX wings
Extreme lotus root snapper2033 5 0
911800 900-1803
900/1200900-1809
650650
725/1800
6541950
575/E733
550F1550
5151300
5591250
4521200
B00/200 0
725:1450
650rL.500
575:1130
550-1:00
S15/1050
200: 1000
812 motor has 3 sizes, motor installation size and equalizing valve, different design, in order to adjust the motor speed range, the minimum allowable process setting toilet 2)
intermittent cycle operation (S3) each sector period is 5 nin, and the excitation is statically connected to the paste. Rated value of motors of various frame numbers (220, 440) Fully enclosed test period continuous cycle duty
Negative wheel holding rate 30%
4) Maximum starting load Maximum suitable running load The maximum value that can be achieved by the performance specification. 5. The maximum sleep value cannot be used to calculate the maximum starting torque. The maximum running torque # is updated. tt||JB/T8163
Basic speed (%)
5.5.2 Compound motor
JB/T81631999
Maximum transfer adjustment rate ()||tt ||】h rated fully enclosed motor or continuous rated external ventilated motor, the excitation Ampere ratio is about 50, parallel excitation (or compensation excitation) Ampere turns 50, series excitation turns (series excitation turns number is close to 5.6 Due to the change in speed caused by heating tj
During the specified operating period, the speed changes from cold full load to hot full load, and the speed changes of fully enclosed motors should be No more than 20% of the rated rotational speed: H of an externally ventilated motor shall not exceed 15% of the rated speed 5.7 Rated speed tolerance
Under normal operating temperature, rated load, rated voltage and rated brush current, The speed tolerance of the motor is ±7.5% of the rated speed.
5.8 Lead wire or terminal box
The location of the lead wire or terminal box of the motor, from the transmission end (i.e. non-commutator end) Look at the motor side. When the motor has a junction box, the axial position of the junction box is offset from the center line and close to the commutator end. When there is no junction box, the relevant dimensions of the lead wire are shown in Table 1. 5.9 Rotational angle | |tt||The motor should be able to run in any direction.
5.10 Axial motion of the armature
The axial motion of the armature shall not exceed 5 m. 5.11 Others
Any requirements not specified in this standard shall comply with the provisions of GB755: 6 Inspection rules
6.1 Each motor must be inspected and qualified before it can be used! , and a product 6.2 Test items and test methods for motors: The test items for motors shall be in accordance with the provisions of GR/T755, and the test methods shall be in accordance with the provisions of GB/T1311, but the following provisions shall be followed when conducting the tests such as F: || tt||a) Rated load test: The test time for continuous rated and intermittent cycle duty motors is 1h. For intermittent cycle duty motors, the rated load test should be carried out according to the 11-hour short-duty duty system. The test time is the short-time working time. After the commutation check: When the motor is from no load to rated load and from base speed to high speed (including the reverse when weakening the magnetic field or increasing the output pressure), the commutation spark level should not b) Short-time over-torque test: the test time is 15s, the torque value is in accordance with the maximum operating torque in Table 3, and the switching level should not exceed level 2; ||tt| |) The motor should be able to withstand a short-term elevated voltage test in the empty state, the test voltage is 130% of the rated voltage, but should not be less than 600V, the test time is 3min, and no failure occurs; JB/T8163||tt| |d Test on insulation dielectric strength between motor windings and casing and between windings: The test voltage of the motor is 2000V and the test time is 1 min.
7 Marking and packaging
7.1 Nameplate marking
The nameplate should have the following markings:
a) Motor name:
b) Manufacturer Name:
) Year of manufacture or code included in the product number: d) Product number of the manufacturer;
e) Product model mark of the manufacturer;
Frame number mark and shaft extension taper (not required when the taper is 1:10)) Standard number and year;
h) Rated voltage and "DC" mark:
1) Rated power ;
i) Working system code and time or duration: k) Rated speed:
D) Maximum safe speed:
m) Rated current:
) Excitation mode (shunt excitation, compound excitation, series excitation or external excitation) ): 0) Rated excitation voltage and rated excitation current: P) Insulation grade;
) Motor quantity, kx;
T) Shell protection grade:
3) External ventilation 7.2 Marking of lead wires
The marking and arrangement of the lead wire terminals shall be in accordance with the provisions of Table 5 (see B191). Table 5 Arrangement and marking of lead wire terminals ||tt ||Frame No.
802 --818
Winding name
Armature winding
Compensating cable group
Internal pole replacement winding
Series-break winding
Parallel excitation Winding
External excitation group
Outlet terminal arrangement
ED Ar(or B,?
E, DB (or A)
Outlet terminal mark
Commutator end
JB/T8163
3The packaging of the motor should ensure that under normal storage and transportation conditions, The goods will not be damp or damaged due to improper packaging within one year from the date of shipment. The words and logos on the outer wall of the packing box will not be damaged due to improper packaging. The markings should be clear and neat, including the following: a) Shipping station and name:
b) Receiving station and receiving unit name;
c) Motor model and factory number: ||tt| |d) Net weight of the motor and gross weight of the box; e) Box size:
) The words "handle with care" and "keep away from moisture" should be marked on the outside of the box. The graphics should comply with the provisions of GB191. 9
JB/T8163
Yanhang880b1230
19XXXXling
100044||tt| |万段X/X
Matrices xXX,XXX
19XX collection XX cabin
Germany pxXX.XX wings
Extreme lotus root snapper2 Compound motor
JB/T81631999
Maximum turn-on adjustment rate ()
】h rated fully enclosed motor or continuous rated external ventilated motor, its excitation Ampere ratio is about 50, parallel excitation (or compensation excitation) Ampere turns 50, series excitation turns (series excitation turns are the nearest integer) 5.6 Due to the speed change caused by heating
During the specified operating period, the speed change from cold full load to hot full load, full For enclosed motors, the rated speed should not exceed 20%; for externally ventilated motors, the rated speed tolerance should not exceed 15% of the rated speed. 5.7 Rated speed tolerance
Under normal operating temperature, rated load, rated voltage and rated brush current, the speed tolerance of the motor is ±7.5% of the rated speed.
5.8 Lead wire or terminal box
The position of the lead wire or terminal box of the motor should be on the side of the motor from the transmission end (i.e. non-commutator end). When the motor has a terminal box, the axial position of the terminal box is past the center line and close to the commutator end. When there is no terminal box, the relevant dimensions of the lead wire are shown in Table 1. 5.9 Rotational direction
The motor should be able to run in any direction,
5.10 Axial motion of the armature
The axial motion of the armature shall not exceed 5 m. 5.11 Others
Any requirements not specified in this standard shall comply with the provisions of GB755: 6 Inspection rules
6.1Each motor shall be inspected and qualified before use! And a product inspection certificate shall be attached. 6.2Test items and test methods of motors: The test items of motors shall comply with the provisions of GR/T755, and the test methods shall comply with the provisions of GB/T1311, but the following provisions shall be followed when conducting the various tests:
a) Rated load test: The test time for continuous rated and intermittent cycle duty motors is 1h. For intermittent cycle duty motors, rated load tests shall be carried out according to the short-duty duty system, and the test time for short-duty duty motors is the short-duty duty time. Commutation check after rated load test: when the motor changes from no-load to rated load and from base speed to high speed (including reverse when weakening the magnetic field or increasing the output pressure), the commutation spark level should not exceed 1 level; b) Short-time over-torque test: the test time is 15s, the torque value is in accordance with the specifications of the maximum operating torque in Table 3, and the commutation spark level should not exceed 2 levels;
) The motor should be able to withstand a short-time increased voltage test under no-load, the test voltage is 130% of the rated voltage, but should not be less than 600V, the test time is 3min, and no failure occurs; JB/T8163
d The insulation dielectric strength test of the motor winding to the casing and the windings between each other: the test voltage of the motor is 2000V, and the test time is 1 min.
7 Marking and packaging
7.1 Nameplate marking
The nameplate should have the following markings:
a) Motor name:
b) Manufacturer's name:
|) Year of manufacture or code included in the product number:
d) Manufacturer's product number;
e) Manufacturer's product model mark;
Frame number mark and shaft extension taper (may not be marked when the taper is 1:10);
h) Rated voltage and "DC" mark:
1) Rated power;
i) Working system code and time Or continuous rate: k) Rated speed:
D) Maximum safe speed:
m) Rated current:
) Excitation mode (shunt excitation, compound excitation, series excitation or external excitation): 0) Rated excitation voltage and rated excitation current: P) Insulation grade;
) Motor quantity, kx;
T) Shell protection grade:
3) Air flow and wind pressure of external ventilation continuous rated motor. 7.2 Lead wire marking
The terminal marking and arrangement of the lead wire shall be in accordance with the provisions of Table 5 (see B191). Table 5 Terminal arrangement and marking
Machine frame number
802 --818
Winding name
Armature winding
Compensating cable group
Internal pole replacement winding
Series-break winding
Shunt-excited winding
Separately excited burning group
Outgoing line terminal arrangement
ED Ar(or B,?
E, DB (or A)
Outlet terminal mark
Commutator end
JB/T8163
3The motor packaging should be able to ensure that under normal storage and transportation conditions, it will not be damp and damaged due to poor packaging within 1 year from the time of shipment.
The text and logo on the outer wall of the packaging box
The text and logo on the outer wall of the packaging box should be neat and clear, and the content is as follows: a) Shipping station and name:
b) Receiving station and receiving unit name;
c) Motor model and factory number: ||tt| |d) Net weight of the motor and gross weight of the box; e) Box size:
) The words "handle with care" and "keep away from moisture" should be marked on the outside of the box, and the graphics should comply with the provisions of GB191. 9
JB/T8163
Yanhang880b1230
19XXXXling
100044
WanduanX/X
MatricesxXX,XXX
19XX CollectionXX Cabin
德pxXX.XX Wing
极藕亥2 Compound motor
JB/T81631999
Maximum turn-on adjustment rate ()
】h rated fully enclosed motor or continuous rated external ventilated motor, its excitation Ampere ratio is about 50, parallel excitation (or compensation excitation) Ampere turns 50, series excitation turns (series excitation turns are the nearest integer) 5.6 Due to the speed change caused by heating
During the specified operating period, the speed change from cold full load to hot full load, full For enclosed motors, the rated speed should not exceed 20%; for externally ventilated motors, the rated speed tolerance should not exceed 15% of the rated speed. 5.7 Rated speed tolerance
Under normal operating temperature, rated load, rated voltage and rated brush current, the speed tolerance of the motor is ±7.5% of the rated speed.
5.8 Lead wire or terminal box
The position of the lead wire or terminal box of the motor should be on the side of the motor from the transmission end (i.e. non-commutator end). When the motor has a terminal box, the axial position of the terminal box is past the center line and close to the commutator end. When there is no terminal box, the relevant dimensions of the lead wire are shown in Table 1. 5.9 Rotational direction
The motor should be able to run in any direction,
5.10 Axial motion of the armature
The axial motion of the armature shall not exceed 5 m. 5.11 Others
Any requirements not specified in this standard shall comply with the provisions of GB755: 6 Inspection rules
6.1Each motor shall be inspected and qualified before use! And a product inspection certificate shall be attached. 6.2Test items and test methods of motors: The test items of motors shall comply with the provisions of GR/T755, and the test methods shall comply with the provisions of GB/T1311, but the following provisions shall be followed when conducting the various tests:
a) Rated load test: The test time for continuous rated and intermittent cycle duty motors is 1h. For intermittent cycle duty motors, rated load tests shall be carried out according to the short-duty duty system, and the test time for short-duty duty motors is the short-duty duty time. Commutation check after rated load test: when the motor changes from no-load to rated load and from base speed to high speed (including reverse when weakening the magnetic field or increasing the output pressure), the commutation spark level should not exceed 1 level; b) Short-time over-torque test: the test time is 15s, the torque value is in accordance with the specifications of the maximum operating torque in Table 3, and the commutation spark level should not exceed 2 levels;
) The motor should be able to withstand a short-time increased voltage test under no-load, the test voltage is 130% of the rated voltage, but should not be less than 600V, the test time is 3min, and no failure occurs; JB/T8163
d The insulation dielectric strength test of the motor winding to the casing and the windings between each other: the test voltage of the motor is 2000V, and the test time is 1 min.
7 Marking and packaging
7.1 Nameplate marking
The nameplate should have the following markings:
a) Motor name:
b) Manufacturer's name:
|) Year of manufacture or code included in the product number:
d) Manufacturer's product number;
e) Manufacturer's product model mark;
Frame number mark and shaft extension taper (may not be marked when the taper is 1:10);
h) Rated voltage and "DC" mark:
1) Rated power;
i) Working system code and time Or continuous rate: k) Rated speed:
D) Maximum safe speed:
m) Rated current:
) Excitation mode (shunt excitation, compound excitation, series excitation or external excitation): 0) Rated excitation voltage and rated excitation current: P) Insulation grade;
) Motor quantity, kx;
T) Shell protection grade:
3) Air flow and wind pressure of external ventilation continuous rated motor. 7.2 Lead wire marking
The terminal marking and arrangement of the lead wire shall be in accordance with the provisions of Table 5 (see B191). Table 5 Terminal arrangement and marking
Machine frame number
802 --818
Winding name
Armature winding
Compensating cable group
Internal pole replacement winding
Series-break winding
Shunt-excited winding
Separately excited burning group
Outgoing line terminal arrangement
ED Ar(or B,?
E, DB (or A)
Outlet terminal mark
Commutator end
JB/T8163
3The motor packaging should be able to ensure that under normal storage and transportation conditions, it will not be damp and damaged due to poor packaging within 1 year from the time of shipment.
The text and logo on the outer wall of the packaging box
The text and logo on the outer wall of the packaging box should be neat and clear, and the content is as follows: a) Shipping station and name:
b) Receiving station and receiving unit name;
c) Motor model and factory number: ||tt| |d) Net weight of the motor and gross weight of the box; e) Box size:
) The words "handle with care" and "keep away from moisture" should be marked on the outside of the box, and the graphics should comply with the provisions of GB191. 9
JB/T8163
Yanhang880b1230
19XXXXling
100044
WanduanX/X
MatricesxXX,XXX
19XX CollectionXX Cabin
德pxXX.XX Wing
极藕亥1 Nameplate markings
The nameplate should have the following markings:
a) Motor name:
b) Manufacturer's name:
) Year of manufacture or code included in the product number:
d) Manufacturer's product number;
e) Manufacturer's product model mark;
Frame number mark and shaft extension taper (may not be marked when the taper is 1:10);
h) Rated voltage and "DC" mark:
1) Rated power;
i) Duty code and time or duration:
k) Rated speed Speed:
D) Maximum safe speed:
m) Rated current:
) Excitation mode (shunt excitation, compound excitation, series excitation or external excitation): 0) Rated excitation voltage and rated excitation current: P) Insulation grade;
) Motor quantity, kx;
T) Shell protection grade:
3) Air flow and wind pressure of external ventilation continuous rated motor. 7.2 Lead wire marking
The terminal marking and arrangement of the lead wire shall comply with the provisions of Table 5 (see B191). Table 5 Terminal arrangement and marking
Machine frame number
802 --818
Winding name
Armature winding
Compensating cable group
Internal pole replacement winding
Series-break winding
Shunt-excited winding
Separately excited burning group
Outgoing line terminal arrangement
ED Ar(or B,?
E, DB (or A)
Outlet terminal mark
Commutator end
JB/T8163
3The motor packaging should be able to ensure that under normal storage and transportation conditions, it will not be damp and damaged due to poor packaging within 1 year from the time of shipment.
The text and logo on the outer wall of the packaging box
The text and logo on the outer wall of the packaging box should be neat and clear, and the content is as follows: a) Shipping station and name:
b) Receiving station and receiving unit name;
c) Motor model and factory number: ||tt| |d) Net weight of the motor and gross weight of the box; e) Box size:
) The words "handle with care" and "keep away from moisture" should be marked on the outside of the box, and the graphics should comply with the provisions of GB191. 9
JB/T8163
Yanhang880b1230
19XXXXling
100044
WanduanX/X
MatricesxXX,XXX
19XX CollectionXX Cabin
德pxXX.XX Wing
极藕亥1 Nameplate markings
The nameplate should have the following markings:
a) Motor name:
b) Manufacturer's name:
) Year of manufacture or code included in the product number:
d) Manufacturer's product number;
e) Manufacturer's product model mark;
Frame number mark and shaft extension taper (may not be marked when the taper is 1:10);
h) Rated voltage and "DC" mark:
1) Rated power;
i) Duty code and time or duration:
k) Rated speed Speed:
D) Maximum safe speed:
m) Rated current:
) Excitation mode (shunt excitation, compound excitation, series excitation or external excitation): 0) Rated excitation voltage and rated excitation current: P) Insulation grade;
) Motor quantity, kx;
T) Shell protection grade:
3) Air flow and wind pressure of external ventilation continuous rated motor. 7.2 Lead wire marking
The terminal marking and arrangement of the lead wire shall comply with the provisions of Table 5 (see B191). Table 5 Terminal arrangement and marking
Machine frame number
802 --818
Winding name
Armature winding
Compensating cable group
Internal pole replacement winding
Series-break winding
Shunt-excited winding
Separately excited burning group
Outgoing line terminal arrangement
ED Ar(or B,?
E, DB (or A)
Outlet terminal mark
Commutator end
JB/T8163
3The motor packaging should be able to ensure that under normal storage and transportation conditions, it will not be damp and damaged due to poor packaging within 1 year from the time of shipment.
The text and logo on the outer wall of the packaging box
The text and logo on the outer wall of the packaging box should be neat and clear, and the content is as follows: a) Shipping station and name:
b) Receiving station and receiving unit name;
c) Motor model and factory number: ||tt| |d) Net weight of the motor and gross weight of the box; e) Box size:
) The words "handle with care" and "keep away from moisture" should be marked on the outside of the box, and the graphics should comply with the provisions of GB191. 9
JB/T8163
Yanhang880b1230
19XXXXling
100044
WanduanX/X
MatricesxXX,XXX
19XX CollectionXX Cabin
德pxXX.XX Wing
极藕亥
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.