This standard specifies the color range and measurement method of gold-like titanium nitride. This standard applies to gold-like titanium nitride decorative film layers. GB/T 15827-1995 Color of ion-plated gold-like titanium nitride GB/T15827-1995 Standard download decompression password: www.bzxz.net
This standard specifies the color range and measurement method of gold-like titanium nitride. This standard applies to gold-like titanium nitride decorative film layers.
Some standard content:
National Standard of the People's Republic of China Ion plating Color of golden titanium nitride Ion plating --Colour nf golden TiN1 Subject content and scope of application This standard specifies the color range of golden titanium nitride and its measurement method. This standard applies to decorative golden titanium nitride films. 2 Reference standards GB 3977 GB 3978 Method of expressing colorbZxz.net Standard illuminant and illumination observation conditions Method of measuring object color GB 3979 Method of indicating color attenuation GB/T 15827—1995 The color of golden titanium nitride is the reflected color of the film. According to the provisions of Chapter 1 and Chapter 2 of GB 3977, it is expressed by the chromaticity coordinates of the XY7. colorimetric system and the stimulus value Y. 4 Color of gold-imitation titanium nitride 4.1 The color range and grades of gold alloys are shown in Table 1. Table 1 Chromaticity coordinates (Dee light source) Brand (yellow-green) (yellow) Approved by the State Administration of Technical Supervision on December 13, 1995 Implementation on August 1, 1996 :com Color brand (light yellow) (yellow) (pink) (red) 0. 359: 1 Note: citing S0)8654&Color of gold alloy GB/T15827—1995 Continued Table 1 Chromaticity coordinates (D, light source) - 74 II 1 Definition, color range and standard method Chapter 4 Table 1 + Source standard reflectance β is changed to stimulus value Y to represent +Y4.2 The color of gold-coated titanium nitride is divided into first grade, second grade and first grade. The color range determined by the chromaticity coordinates is shown in Table 2, and the position on the chromaticity diagram is shown in the figure. 0. 33~~0. 36 0.36~~0. 40 0. 40~0. 42 0.35~~0. 38 0. 38-~0. 40 0. 40--0. 42 4.3 The color grades of imitation gold titanium nitride can be divided into imitation 1N, 2N, imitation 3V, etc., and their color tones should basically match the corresponding gold alloy color grades. GB/T 15827- XYZ colorimetric system chromaticity diagram 4.4 The color of the same sample should be uniform and consistent, and there should be no obvious color difference when observed by naked eyes. 5 Measurement method 5.1 Basic method 5.1.1 Sample Instrument measurement Use a flat sample with a size of not less than 25 mm×20 mm and a surface roughness R of ≤0.08 um5.1.2 Instrument 5.1.2.1 Use an integrating sphere spectrophotometer that meets the requirements of 13.1 in GB 3979. 5.1.2.2 The standard light source is D65 light source, C light source or A light source specified in 4.3, 4.2 and 4.1 of GB 3978. 5.1.2.3 The lighting and observation conditions shall be the 0/t conditions specified in 5.3 of GB3978, that is, the measurement of the specular reflection component shall be carried out without using a gloss absorber and under the "vertical/diffuse" conditions. 5.1.3 Measurement process 5.1.3.1 According to 3.2 of GB3979, measure the spectral reflectance p(a) of the sample. 5.1.3.2 According to 3.2.4 of GB3979, the three stimulus values X, Y, and Z shall be calculated using the equal wavelength interval method. See formula (1). X =Es()()p(A)A Y Es(a)yta)p(a)aa 7. = ES(A)2()p(A)x Wherein: S()--Relative spectral power distribution of standard illuminant:(), (A), ()Color matching function in XYZ colorimetry system: p) Spectral reflectance of a sample Wavelength interval. Weighting coefficient S(A)(A).S()().S()(A) values are shown in Appendix A (Supplement). .(1) GB/T15827—1995 3Calculate the chromaticity coordinate 3 value according to 5.1 of GB3977, see formula (2). 5.1.3.3 C=X-+z 3=x+y+7 or: X, Y, z 5.2 Auxiliary methods 5.2.1 Standard color plate Tristimulus values in the XYZ colorimetric system. Lunar colorimetry The standard color plate shall conform to the chromaticity coordinates and stimulus values given in Table 1 as the reference color scale for daylight colorimetry, and its size shall not be less than 25 mm × 20 mm. 5.2.2 Observation conditions The lighting observation conditions shall be the 45/0 or 0/45 conditions specified in 5.1 of GB3978, using Ds light source, C light source, A light source or natural light, with an illumination of 001x or more, and a background grayscale of N6. 5.2.3 Visual colorimetry Place the sample and the standard color plate side by side, cover the surface with a tracing paper, and then press it with a white mask with a rectangular opening. Visually compare the color wavelength a of the sample and the standard color plate from the opening GE/T15827:-1995 Appendix A Weighting coefficients of color matching functions of CIE standard illuminants and CIE1931 standard colorimeter observers (supplement) 0, 610 C, 171 0, 037 0, 694 0- 347 5, 374 199-B28 Xie Jia Note: S(a)(A) GB/T 158271995 Continued Table A1 This standard was proposed by the Ministry of Machinery Industry of the People's Republic of China. sa This standard is under the jurisdiction of the National Technical Committee for Standardization of Metallic and Non-metallic Coatings. s()r(a> S(a)yta) This standard was drafted by the Clock and Watch Research Institute of the Ministry of Light Industry, and Beijing Instrument Factory and Tianjin Heat Treatment Institute participated in the drafting. The main drafters of this standard are Min Zuzhang, Zhang Xuerong, Yang ZiweiSA( 108,814 Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.