JB/T 10178-2000 This standard specifies the structural type, basic parameters, technical requirements, test methods, inspection rules, marking, packaging, transportation and storage requirements of horizontal fluidized bed dryers. This standard applies to horizontal fluidized bed dryers. This standard is published for the first time. JB/T 10178-2000 Horizontal fluidized bed dryer JB/T10178-2000 Standard download decompression password: www.bzxz.net
Some standard content:
ICS23.160 Machinery Industry Standard of the People's Republic of China JB/T10178-2000 Horizontal fluidized-bed dryer2000-03-30 Issued State Administration of Machinery Industry 2000-10-01 Implementation JB.T10178—2000 Appendix A of this standard is the summary of the standard. This standard was proposed and approved by the Technical Committee for Standardization of Drying Equipment. The drafting units of this standard are: Zhejiang University Chemical Technology Equipment Research Institute, Hangzhou Raojiang Airborne Products Factory. The main drafters of this standard are: Yang Ayi, Sun Le, Cheng Zha, Zheng Xiongping, Du Zhihao. Scope Machinery Industry Standard of the People's Republic of China Horizontal fluidized-bed dryer Forizaatal fluidized-bed dryerJB/T10178-2000 This standard specifies the structural type, basic parameters, technical requirements, test methods, inspection rules, marking and packaging, transportation and storage requirements of horizontal fluidized-bed dryers (hereinafter referred to as dryers). 4 The standard applies to horizontal fluidized-bed dryers. 2 Cited Standards The provisions contained in the following standards constitute the provisions of this standard through reference in the standards. When this standard is published, the versions shown are valid. All standards will be reviewed. Parties using this standard should explore the possibility of using the latest versions of the following standards: GB[51—199] GB/T·6388-1992 GB:T.13306—2991 [ET6924—1998 SJ:T 10674—I995 3 Terminology Packing Huayun Graphic Logo Operation and Maintenance Manufacturing and Shipping Information Model Compilation Method for Door-Controlled Equipment General Technical Parts for Rolling and Coagulation This standard adopts the following definitions: 3.1 "Coal Strength (symbol is 1,) The weight of water removed by the dryer per unit time and per unit fluidized bed distribution area under given working conditions, unit: kg (m+h). 4 Product Classification 4.1 Structure 4.1. The dryer is a multi-chamber dryer. bZxz.net 4.1.2 The dryer consists of a chamber, a distribution system, and a condenser. 4.2 Methods of representation 4.2.1 Methods of representation of models JR/T6924: National Machinery Industry Council 2000-03-30 approved 2006-10-01 implementation 4.2.1 Example of marking . JB/T10178—2000 Improved design sequence code [Change to A, B, C -] Main features, represented by gas distribution plate size (width × length, 10-m). Auxiliary features (structural type, treatment type) code is represented by the first letter "W" of the Chinese pronunciation of "Wo" in horizontal fluidized bed. The main features (main equipment type code is represented by the first letter "" of the Chinese pronunciation of "Liu" in fluidized bed. Professional code The first letter "" of the Chinese pronunciation of "T" in dry equipment is used to represent the fluidized bed gas distribution vehicle. The horizontal fluidized bed dryer with a width of 300mm and a length of 1800mm is GLW-3. × 18 4.3 Basic vertical number Basic parameter effect of ten machines meets the requirements of the table. Table "Basic number Basic data 3 ×18 4 ×24 9 × 30 6 × 36 10 ×60 12x 72 16 ×8 20×100 20 ×120 39 × 150 5 Requirements Gas distribution plate size (two × length 300 ×1800 400×2400 600 × 3600 800×4800 1000 ×6000 1200×7200 [600×960u 2000 ×16000 2000 ×12000 3000 ×15000 distribution plate volume operation code should comply with the requirements of all standards, and be manufactured in accordance with the specified procedures and technical documents, 5.1 5.2 Station specifications: Gas distribution in each room of fluidized bed should be evenly distributed, and can be adjusted at will: the gas disk in each room should be able to be adjusted up and down within a certain range;) Installation guarantee materials: dry spider tension kgrim-hy d) It has the conditions of observation support and excitation measurement device, 5.3 Appearance quality J8/T10178-2000 5.3.1 The appearance quality of the layer M meets the appearance quality requirements of Class I and II coating in SJ/T10674 5, and the mixed holes are arranged neatly. 5.3.3 The edges of the close-fitting parts should be aligned. 5.4 Load technical performance 5.4.1 When conducting the explosion performance test according to Appendix A (standard resistance to recording), the strength of the dryer should meet the requirements in the table. 5.4.2 The dryer should be able to meet the requirements of other effective materials within the applicable range. 5.5 Under the conditions of the user's reverse drying machine storage and use rules, the dryer should not be operated for more than 1M (except for wearing parts). 6 Test method 6.1 After each single machine is rotated, determine the main dynamics, check the compatibility, and debug the system before operation. 6.2 The strength of the dryer is tested in reverse according to the provisions of Appendix A, and the results meet the requirements of 5.1.1. 6. The dryer is within the range selected by the hospital and meets the drying requirements of other materials. According to the requirements of the material drying process in the production case, the dryer is tested on site to test the degree to which the dryer meets the user's requirements for the drying effect of the material (it can be evaluated according to standards, agreements or contracts! 6.4 In the dryer gear test, the manufacturer conducts the test at the test point established by the user and submits the report. The result meets the requirements of 5.5.7 Inspection Rules 7. The dryer must pass the inspection of the product inspection department of the manufacturer and be accompanied by a product quality certificate before it can be shipped! 7.2 The inspection of the dryer is divided into factory inspection and model modification inspection. 7.2.1 Factory inspection 7.2.1. Each lower end dryer is subject to factory inspection and a no-load running test of no less than 2 hours. 7.2. 1.2 If any of the factory inspection items fails, the product shall be deemed unqualified. 7.1.2 For products that have been assembled, the factory inspection items can be carried out on the installation and commissioning site, and the site inspection results determined by the commissioning personnel can be used as the basis for product change. 7.2.2 Scraping test . 2.2.1 When one of the following conditions is met, the product shall be inspected: During product trial production or transfer to another factory: b When the product has been discontinued for 2 years During production: Normal production, 100 units per year (referring to the same specifications); d Product structure, material: When there is a change in the system: When the national standard requires type testing. 7.2.2.1 Type inspection includes the inspection contents, and the requirements of 5.4.1 shall be inspected. 7.2.2.3 When the requirements of 54.1 cannot be inspected due to customer reasons, the inspection of 5.4.2 may be used instead of 7.2. 2.4. Vertical type machine can be selected from any machine. If the inspection is not in accordance with 5.4.2, the prototype can be selected at any time through consultation by relevant personnel. 7.2.1.5 During the type inspection, if one of the items other than 5.5 is not in accordance with the requirements, double sampling should be carried out for re-inspection. If there is still one item that is not qualified, it will not be accepted. 8 Marking, packaging, transportation and storage 8.1 Punctuation 8.1.1 Product The product label shall be placed in a conspicuous place. Its type, size and technical requirements shall comply with the provisions of GB/T 13306. The label shall include: a) Name and address of manufacturer: Product name: Trademark: Product model: e) Date of manufacture: Product export number and production number; 8) Product main parameters. 8.1.2 Packaging mark The outer surface of the packaging material of the vehicle product shall have the marks of delivery, packaging, storage and transportation, etc. The packaging mark shall comply with the provisions of GB/T 13306. 8.2 Packaging 8.1.1 The products should be packed in boxes. The boxes should be shaded from rain. 8.2.2 Documents accompanying the products should include: a) Product certificate: b) Product instruction manual (including product installation diagram); and installation list (including random preparations, tools and cleaning list). 8.3 Transportation: The transportation should be covered and tidy. There should be other measures to prevent rain. 8.4 Storage: 8.4.1 The storage site should be flat, airtight and dry. 8.4.2 During storage, the storage room should be kept dry or have other measures to prevent dew. 8.4. The storage room should be maintained once every month if it exceeds 1 month. A1 Test instruments JB/10178-2000 (Standard Appendix) Horizontal fluidized bed dryer for dry strength test method The moisture content of the material is determined by the loss method, measured in an oven, the temperature is not higher than 105°C, and the temperature is determined by a thermometer with an error of no more than 1°C. A2 Test conditions 42.1 The material is selected as yellow powder with a thickness of 0.17-0.25mm and a moisture content of 3%~5%. A2.2 The fluidized bed is equipped with a material as the bottom material, and the static bed height is: 150mm±5mm. A2.3 The components of the dryer meet the following requirements: a) The empty bed gas velocity of the dryer: 0.8~t.0ml/sh) The air inlet temperature of the dryer drying section: 120℃±2℃: The effective moisture content: 0.3%. Test method Prepare the initial moisture content of 3%~5% yellow soda ash, which cannot be determined by mixing (Appendix). After the semi-dryer reaches the working state specified in A2.3 and operates stably for h, take samples from the discharge port every 30m, and the sampling frequency is about 50 seconds: Determine the moisture content of one sample; calculate the arithmetic mean value of three samples (in terms of weight); measure the material feed rate from time to time during the sampling process (in terms of weight). 1 Drying strength calculation Combustion strength formula (A): I: —— 【single shot, kgnh): m material selection salt, kg'h: %—Material moisture content before explosion: wet basis), %: H: Material moisture content of drying plate {wet basis), %: .4. Bottom area of drying section of dryer, m. Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.