title>GB/T 11606.1-1989 General principles for environmental test methods for analytical instruments - GB/T 11606.1-1989 - Chinese standardNet - bzxz.net
Home > GB > GB/T 11606.1-1989 General principles for environmental test methods for analytical instruments
GB/T 11606.1-1989 General principles for environmental test methods for analytical instruments
Basic Information
Standard ID:
GB/T 11606.1-1989
Standard Name: General principles for environmental test methods for analytical instruments
Standard ICS number:Test >> 19.040 Environmental Test
Standard Classification Number:Instruments and meters>>Material composition analysis instruments and environmental monitoring instruments>>N50 Material composition analysis instruments and environmental monitoring instruments comprehensive
GB/T 11606.1-1989 General principles for environmental test methods for analytical instruments GB/T11606.1-1989 Standard download decompression password: www.bzxz.net
Some standard content:
UDC681.2:543.08:621.317.08 National Standard of the People's Republic of China GB11606.1~11606.17-89 The method of environmental testfor analytical instruments Published on March 31, 1989 Implemented on March 1, 1990 Published by the State Administration of Technical Supervision GB11606.1—89 GB11606.2-89 GB11606.3—89 GB 11606.4—89 GB11606.5—89 GB11606.6--89 GB11606.789 GB11606.8-89 GB11606.9-89 GB11606.10-89 General principles for environmental test methods for analytical instruments Environmental test methods for analytical instruments Power frequency and voltage test Environmental test methods for analytical instruments Test methods Low temperature test Environmental test methods for analytical instruments High temperature test Environmental test methods for analytical instruments Temperature change test Environmental test methods for analytical instruments Constant humidity test Environmental test methods for analytical instruments Alternating damp heat test Environmental test methods for analytical instruments Environmental test methods for analytical instruments Vibration test Test Magnetic field test· Air pressure test GB11606.11—89 Environmental test methods for analytical instruments Sand and dust test GB11606.12-89 Environmental test methods for analytical instrumentsLong series test·GB11606.13--89Environmental test methods for analytical instrumentsSalt spray test GB11606.14--89Environmental test methods for analytical instrumentsLow temperature storage test GB11606.1 5-89 Environmental test methods for analytical instruments High temperature storage test GB11606.16--89 Environmental test methods for analytical instruments GB11606.17--89 Environmental test methods for analytical instruments Drop test Magnetic impact test Amendment No. 1 to GB/T11606.1-1989 "General Rules for Environmental Test Methods for Analytical Instruments" This amendment was approved and issued by the State Administration of Quality and Technical Supervision on July 19, 2000, and took effect on December 1, 2000. Published in the 9th issue of 2000 (China Standardization). 1. In Chapter 4, \50±0.1H\ is changed to \50±0.5H\. 2. In Chapter 5, "Constant temperature test" is changed to "Constant damp heat test". 3. The units in Table 1 should be placed below the project name. The test item "humidity" should be changed to "humid heat". The "humidity\" column in Table 1 is modified as follows: Test purpose Test conditions Constant damp heat Alternating damp heat Rated operating temperature upper limit -5℃ -20~460 (95±%) National Standard of the People's Republic of China The method of environmental test for analytical instruments The method of environmental test for analytical instruments instrumcntsGeneral 1 Subject content and scope of application GB11606.1--89 This standard specifies the environmental test grouping, reference working conditions, test items, selection of environmental groups, environmental tests and test procedures for analytical instruments (hereinafter referred to as instruments). This standard is not applicable to marine analytical instruments. 2 Reference standards GB2422 Environmental test procedures for electrical and electronic products Terminology GB2298 Mechanical vibration shock 3.1 Group I The ambient temperature and humidity are controlled within the specified range, usually refers to a controlled environment with air conditioning equipment. Be careful when operating the instrument. This group is suitable for precision instruments. 3.2 Group II Only the ambient temperature is controlled within the specified range, usually refers to an indoor environment with general insulation, heating and ventilation. The instrument is allowed to be subjected to general vibration during use. This group Applicable to laboratory instruments, 3.3 Group Environment without ambient temperature and humidity control, usually refers to indoor environment without insulation, heating and ventilation. The use and transportation conditions of the instrument are poor. This group is suitable for industrial process instruments, 3.4 Group IV Harder environment without ambient temperature and humidity control, usually refers to outdoor environment with or without shelter. The instrument may be subject to drastic environmental changes during use or transportation 4 Reference working conditions Reference working conditions Reference values, errors and ranges are shown in Table 2. Without generating When there is disagreement, the test can be conducted under the conditions of 20±10℃, relative humidity less than 75%, power supply voltage of 220±22V, and power supply frequency of 50±0.1Hz. 5 Test items There are 16 environmental tests, namely power supply frequency and voltage test, low temperature test, high temperature test, temperature change test, constant mixing test, alternating damp heat test, vibration test, magnetic field test, air pressure test, sand and dust test, long test, salt spray test, low temperature storage test, high temperature storage test, drop test and collision test. Approved by the Ministry of Machinery and Electronics Industry of the People's Republic of China on March 25, 1989 and implemented on March 1, 1990 6 Selection of environmental grouping GB11606.1-89 6.1 The product standard shall select the environmental grouping according to Chapter 3. If a certain (generally only one) impact quantity is not completely consistent with the environmental conditions of the specified group, the product standard shall be specified separately. 6.2 When it is not feasible to test a large product as a whole, the relevant standards shall specify which key parts or components shall be tested. 6.3 The test items listed in Table 1 are the items that the instrument must perform. 7 Environmental Tests Each test usually includes the following items: Pretreatment (if necessary); b. Initial inspection (if necessary): c. Test; d. Intermediate inspection (if necessary); e. Recovery (if necessary); f. Final inspection. Test Sequence When two or more test items are performed on the same instrument in sequence, the sequence is generally not specified. If the test sequence has an impact, it shall be specified by the relevant standards. Table 1 Grouping of environmental test conditions Test items Test conditions Lower limit of extreme working humidity Lower limit of rated working temperature Upper limit of rated working temperature Upper limit of extreme working temperature Temperature change Constant humidity Alternating damp heat Frequency range Hz Amplitude value Bee value mm Frequency sweep rate Holding time min Vibration direction +15~30℃ (75)% 0~+40℃ -10~+50℃ 5~33~5 -20+60c 5~55~5 0.075~0.19 Time per minute Frequency range X, Y, Z Test items Power supply frequency and voltage Transportation, Test conditions Rated frequency Hz Low temperature ℃ Influence quantity Ambient temperature Relative humidity Atmospheric pressure AC power supply voltage AC power supply frequency||tt ||AC power supply waveform External electrical, magnetic and electromagnetic interference Mechanical vibration Air velocity Working position Sunlight exposure Harmful gases GB11606.1-89 Continued Table 1 50±0.5(or 60±0.5;8≤0.05) 220±22(8≤0.05) Acceleration: 10±1g; Pulse duration: 11±2ms Pulse repetition frequency: 1~1.7Hz Continuous impact times: 1000±10 times Pulse waveform: Approximately half-sine wave When the weight of the package is greater than 100kg and less than 200kg, it is tilted and dropped (when the length of the bottom edge is less than 500mm, the inclination angle is 30°; when the bottom edge is greater than or equal to 500mm, the highest height of the inclined bottom from the ground is 250mm) When the weight of the package is not more than 100kg, it is free to fall and the drop height is 250mm Table 2 Reference working conditions Reference Value or range (45~75)%\) 86~106kPa Rated voltage Rated color Sine wave Should be avoidedbzxz.net Negligible According to product standards Good, no convection Avoid direct sunlight Negligible Negligible Note: 1) Ambient humidity and atmospheric pressure are within this range. Any value error 2) β is the distortion factor, that is, the distortion of the AC power supply voltage waveform should be kept between the envelope formed by (1+8)Asinの! and (1-β)Asinot3 Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.