This standard only specifies the uniform colors of indicator lights and buttons in electrical complete sets. GB 2682-1981 Colors of indicator lights and buttons in electrical complete sets GB2682-1981 Standard download decompression password: www.bzxz.net
Some standard content:
1 Scope National Standard of the People's Republic of China Colors of Indicators and Buttons in Complete Electrical Installations This standard only specifies the uniform colors of indicators and buttons in complete electrical installations. 2 PurposeWww.bzxZ.net The significance of the use of uniform colors of indicators and buttons is to ensure personal safety and facilitate operation and maintenance. 3 Auxiliary representation GB 2682-81 When color alone cannot represent the operating function or operating status, necessary graphic symbols or text symbols may be added on or near the device. When required, an audible signal (including an execution button with a release sound) may be added in advance while the indicator light emits a colored fixed light or flashing information. 4 Standard provisions 4.1 Available colors Red, yellow, green, blue and white are used for indicators: red, yellow, green, blue, black, white and gray are used for buttons. 4.2 Color selection principle Select the color according to the function caused by the button being operated (pressed), or the information reflected by the indicator light after being turned on (lighting). 4.3 The role of flashing information 4.3.1 To attract attention; 4.3.2 To take immediate action: 4.3.3 The information reflected does not meet the requirements of the instruction; 4.3.4 To indicate the change process (flash during the process). The ratio of light to off time is generally selected between 1:1 and 4:1. For higher priority information, use a higher flashing frequency. 5 Color of indicator light 5.1 The role of light information 5.1.1 Indication: to attract the attention of the operator, or to indicate a certain operation that the operator should perform; 5.1.2 Execution: to reflect that a certain instruction, a certain state, certain conditions, or a certain type of evolution is being executed or executed. 5.2 Meaning of color instructions Indicator light color and its meaning Danger or emergency Announced by the Bureau The First Ministry of Machinery Industry of the People's Republic of China stated that There is danger or immediate action is required Lubrication system pressure loss: Temperature has exceeded the (safety) limit Shutdown due to action of protection device; There is danger of touching live or pressurized parts. Implemented on July 1, 1982 Tianjin Electric Drive Design Institute Shanghai Electric Complete Plant 6 Button color Specify as needed No specific intention GB 2682--81 The situation has changed, or is about to change normal or allowed any specified purpose except red, yellow and green. For example: when red, yellow and green cannot be used accurately , and when used as "execution", "stop", "power off" or "accident" use red button; "start" or "power on" use green button first, black, white or gray button is allowed; one button has two functions: "start" and "stop" or "power on" and "power off"; for example, continued Table 1 abnormal temperature (or pressure); the semi-instrument can withstand the allowable short-term discussion normal cooling and ventilation: automatic control system is running normally Normal; The machine is ready to start Remote control indication; Select the "set" position If the function changes after pressing alternately, neither the red button nor the green button can be used, but the black, white or gray button should be used; if the movement is moved when pressed and stopped when lifted (such as inching or micro movement), the black, white, gray or green button should be used, preferably the black button, and the red button should not be used; "Reset" For single-function, use a blue, black, white or gray button; if there is a "stop" or "power off" function, use a red button. Button colors and their meanings Black, gray, and white Handling accidents Emergency stop: Extinguish burning "Stop" or "Power off" "Start" or "Power on" Any designated purpose not included in the above colors No specific purpose Normal stop; Stop one or more motors; Partial stop of the device; Cut off a switch, Reset with "stop" or "power off" function to prevent unexpected situations Condition: Participate in suppressing abnormal conditions; Avoid unnecessary changes (things to do) Normal start: Start one or more motors Partial start of the device; Connect a switch device (put into operation) For purposes not covered by red, yellow and green, blue can be used Table 2 Any function except single-function "stop" or "power off" button 7 Illuminated pushbutton 7.1 Type Type of pushbutton GB 2682-81 Type of illuminated pushbutton No specific color (non-color) No specific color (non-color) No change in color Any color Different colors (each color has its own light) 7.2 The provisions of Articles 5 and 6 also apply to illuminated pushbuttons. When it is difficult to choose a color, white is allowed. 7.3 Information function of light button 7.3.1 Instruction: The light on the button is turned on to inform the operator that he needs to press the button with the light on to complete a certain operation. After pressing, the light will be on to reflect that a certain instruction has been executed. When it is necessary to attract the operator's attention (such as an alarm), a flashing light button can be used. After the button is pressed, the flashing light can be changed to a fixed light. Before the cause of the alarm is eliminated, the fixed light will not be lit. 7.3.2 Execution: After pressing the light-off button, the light on the button will be turned on to reflect that a certain instruction has been executed (until the execution is released, the light will be turned off). When pressed, if the flashing light on the button is on, it means that a certain instruction or a certain type of evolution is being executed. After the execution is completed, the flashing light must be automatically changed to a fixed light. 7.4 Light buttons shall not be used as emergency buttons. Appendix Application type High and low voltage rooms or test areas Distribution switchboard Control and power supply devices of machines Ventilators for extracting dangerous gases Conveying devices in which the conveyed materials will solidify When conveying stops Main power circuit breaker Branch switch Power circuit breaker Various starters Starting of motors Starting of motors GB 2682-81 Examples of color selection for indicator lights Installation location On the entrance outside the room (area) On the switch board Operator's console On the air duct opening Operator's console And in areas where harmful gases may gather Near the transport aircraft Operator's console Light information for the operator It is dangerous to enter Branch power supply No power in the branch Purpose of light information There is a risk of electric shock Indicator light is not on: No power supply Ready Machine running Note: The fan is extracting Stop extracting The conveyor is working, Do not touch, leave Normal operation The conveyor is overloaded, Reduce the load Stop for overload, restart Normal state The machine or operating cycle The system can be started, etc. Ready Confirmation of starting Normal state Action must be taken immediately Selected color Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.