Standard ICS number:Fluid Systems and General Parts >> 23.080 Pumps
Standard Classification Number:Electronic Components and Information Technology>>Information Processing Technology>>L71 Coding, Character Set, Character Recognition
GB/T 11473-1989 Method for compiling the model of reciprocating pumps GB/T11473-1989 Standard download decompression password: www.bzxz.net
Some standard content:
National Standard of the People's Republic of China The model desigeation of reciprocatng pump1Subject content and scope of application This standard specifies the model desigeation of reciprocatng pump. This standard is applicable to mechanical, gas (steam) driven, hydraulic and manual reciprocating pumps. 2 Model Indication Method The model of a reciprocating pump consists of capital Chinese Pinyin letters and Arabic numerals, and the indication method is as follows: 0 0 0-0/00.0 Variable model: indicated by numbers 1~9 Special performance: indicated by letters Rated discharge pressure: indicated by numbers, MPaRated flow: indicated by numbers GB 11473—89 Structural type: vertical type is L, diaphragm type is M, and other types are not indicated. First characteristic: indicated by letters Number of couplings (cylinders): indicated by numbers, single coupling (cylinder) is not indicated. Note: ①The first characteristic of the pump refers to the most representative feature of the pump selected from the five categories of pump driving mode, auxiliary medium, structural characteristics, functions and main supporting facilities (see Table 1). ②The content in the dotted box is the reference section (see Chapter 4). Approved by the Ministry of Machinery and Electronics Industry of the People's Republic of China on March 29, 1989 and implemented on January 1, 1990 Pneumatic (steam) pump Electric pump Hydraulic pump Hydraulic pump Metering pump Hand pump General motor pump Impurity pump First feature Oil isolation Water isolation Water flushing 3 Rated flow and rated discharge pressure 3.1 The units of rated flow are stipulated as follows: a. Metering pump and pressure test pump: L/h, b. Manual pump: mL/time: other pumps: m*/h; GB1147389 recorded gas (steam) water gas) oil gas (steam) 3.2 The rated flow of the adjustable volume pump marks the maximum rated flow value of the pump. 1. Characteristics General motor pumpsbzxZ.net Chemical pumps and Other pumps First characteristics Catalysts Fluorine Carbamic acid Silicic acid baking liquid Deionized Copper acetate ammonia liquid Steam condensate 3.3 The rated flow of multi-cylinder metering pumps is expressed by multiplying the number of cylinders by the rated flow of a single cylinder. The rated flow of other multi-cylinder pumps is expressed by the sum of the rated flows of each cylinder. 3.4 For multi-unit metering pumps, the rated flow and rated discharge pressure of each unit cylinder should be listed separately, and the parameters of each unit should be separated by a withdrawal sign. 4. The last two boxes in the model representation method are reference sections, which can be marked or not. Special performance is represented by the code specified in Table 2. If multiple special properties need to be marked in parallel, they can be marked in the order of letters in Table 2. Special properties Throttle flow Guard jacket Marking example 2QY-22/3.5 GB 11473—89 Table 2 Special properties of pumps Letter code Double-cylinder horizontal pneumatic reciprocating oil pump, rated flow 22 m/h, rated discharge pressure 3.5 MPa. b. DY-63/5 Single-cylinder horizontal electric test pressure pump, rated flow 63L/h, rated discharge pressure 5MPa. c.SYL-22/5 Single-cylinder vertical manual test pressure pump, rated flow 22mL/h, rated discharge pressure 5MPa. d.JM-100/2.5 single cylinder horizontal diaphragm electric metering pump, rated flow 100L/h, rated discharge pressure 2.5MPa3J-2×2509/1,40/0.6-T1 two-unit horizontal electric metering pump, the first and second unit flow rates are 2500L/h respectively, and the rated discharge pressure is 1MPa. : The third unit rated flow rate is 401./h, the rated discharge pressure is 0.6MPa, the flow rate can be adjusted, the first modification. f. 2QM-40/0. 7 double cylinder horizontal pneumatic diaphragm pump, rated flow 40m*/h, rated discharge pressure 0.7MPa. SDM-100/0. 3 single cylinder manual diaphragm slurry, rated flow 100mL/time, rated discharge pressure 0.3MPa. 3JA-60/1, 5-B Three-cylinder horizontal electric reciprocating methyl ammonium pump, rated flow 60m2/h, rated discharge pressure 1.5MPa, explosion-proof. 1.3S-40/10 Three-cylinder horizontal electric reciprocating water pump, rated flow 40 gong*/h, rated discharge pressure 10 MPa. 3KM-30/2-T2 Three-cylinder horizontal electric diaphragm impurity pump, rated flow 30m*/h, rated discharge pressure 2MPa, adjustable flow, second variant. k.3KC-180/2.5 Three-cylinder horizontal water flushing electric impurity pump, rated flow 180m/h, rated discharge pressure 2.5MPa Additional remarks: This standard is drafted by Hefei General Machinery Research Institute. The main drafters of this standard are Xiang Qinan and Xu Jianqiang. From the date of implementation of this standard, the former Ministry of Machinery of the People's Republic of China issued the Ministry of Standards JB4134-85 "Method for Compiling Reciprocating Pump Models" will be invalid. Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.