This standard specifies the basic dimensions of the base and installation of axial suction centrifugal pumps. In order to adapt to various installation conditions, this standard gives the positions and numbers of holes for fixing the base that can be freely selected. GB/T 5660-1985 Dimensions of base and installation dimensions of axial suction centrifugal pumps GB/T5660-1985 Standard download decompression password: www.bzxz.net
Some standard content:
National Standard of the People's Republic of ChinawwW.bzxz.Net Axial Suction Centrifugal Pumps Baseplate and Installatlon Dimensions UDC 621.6T GB 5660--85 1S0 3661-1977 This standard specifies the basic dimensions of the base and installation of axial suction centrifugal pumps. In order to be suitable for various installation conditions, this standard gives the positions and numbers of holes for fixing the base that can be freely selected. This standard is mainly applicable to the connection dimensions of axial suction centrifugal pumps that meet GB5662-85 "Marking, Performance and Dimensions of Axial Suction Centrifugal Pumps (16bar)" and motors with base feet. The motor size should comply with the provisions of JB3074-82 "Technical Conditions for Y Series (IP44) Three-Phase Asynchronous Motors (H80~280mm)". Other types of pumps may also adopt this standard if appropriate. This standard is equivalent to the international standard IS036611977 "Axial suction centrifugal pump base dimensions and installation dimensions". The base number and dimensions shall comply with the provisions of the figure and Table 1. The basic installation dimensions shall comply with the provisions of Table 2. The base size is found from Table 2 according to the pump size mark and the corresponding motor base number. Then, the size of the base number is found from Table 1. Table 1 Base number and size Base number L,±25 d*Hole screw control Properties: The dimensions L, and B, in the table are respectively! The length and width of the working area, excluding casting deviations. * According to the provisions of the rough assembly bolts in GB15276 "Fastener through hole countersunk head seat size". National Bureau of Standards 1986-11-25 Issued 7 1986-09-01 Implementation GB 5660-85 Basic dimensions of base and installation Motor Working area City L, xB, Note: ① m is the maximum allowable height of the base, which includes the thickness of the gasket that may be placed between the base and the pump motor. The actual height can be less than this value. ② The dimensions mx and m do not include additional bottom structural parts, such as the height of the foot of an independent device, the alarm, etc. ③ The positions of five holes (A, B, C, D, E) are marked in the figure. The base can also have four (A, B, C, D) or three holes (A, C, E), which is determined by the pump manufacturer. Pump size marking" 150315 GB 5660B5 Sleeping seat number and installation size selection 160180180 Basic installation size :①H in the table is the maximum allowable height, and the actual size + H can be less than this value. When giving the Hmx value of each size pump, the following is taken into account. According to GB 5662-85. ** According to JB 3074. GB5660-85 The maximum height of the largest base equipped with the pump and the centerline height of the pump or motor (the centerline height takes the larger value of the two)②The left side of the thick line in the table is that the centerline of the pump is higher than the centerline of the motor, and the right side is that the centerline of the motor is higher than the centerline of the pump. This standard was drafted by the Machinery of the People's Republic of China This standard was drafted by the Shenyang Pump Research Institute. The drafter of this standard is Huang Yuying. Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.