This standard specifies the type, basic parameters, technical requirements, test methods, inspection rules, marking, packaging and transportation requirements of YH series (IP44) marine three-phase asynchronous motors. JB/T 5273-2002 YH series (IP44) marine three-phase asynchronous motors JB/T5273-2002 Standard download decompression password: www.bzxz.net
Some standard content:
ICS29.160.30 Machinery Industry Standard of the People's Republic of China JB/T5273—2002 Replaces JB/T5273—1991wwW.bzxz.Net Specification for series YH(IP44)three-phase asynchronous motor for marine use (frame size 80~355) Specification for series YH(IP44)three-phase asynchronous motor inships(Frame size 80 to 355) Issued on December 27, 2002 Implementation on January 1, 2003 Issued by the State Economic and Trade Commission of the People's Republic of ChinaForeword Normative referenced documents Type, basic parameters and dimensions Technical requirements, Test methods Inspection rules Marking, packaging, transportation and storage Warranty period JB/T5273—2002 JB/T5273—2002 This standard is a revision of JB/T5273-1991 "Technical conditions for Y-H series (IP44) marine three-phase asynchronous motors (frame size 80280)". Compared with JB/T5372-1991, the main changes of this standard are as follows: The writing format is in accordance with GB/T1.1-2000 and GB/T1.2-2002. The power range is expanded. The original standard specifies the frame number of 80-280, and the frame number specified in the revision is expanded to 80-355, and the corresponding technical content is supplemented, and the standard name is also slightly changed. According to the provisions of GB/1993-1993, the cooling method code of the motor is changed to IC411. - According to the provisions of GB/T4772.1-1999, the motor installation size A/2-item is deleted. According to the provisions of GB10068-2000, the vibration limit of the motor is modified. According to the provisions of GB755--2000, the tolerance of the guaranteed value of some parameters of the motor is supplemented. According to the provisions of China Classification Society's "Rules for Classification and Construction of Steel Seagoing Vessels" (2001), the ambient temperature and temperature rise limit of the motor are modified. This standard replaces JB/T5273---1991. This standard is proposed by China Machinery Industry Federation. This standard is under the jurisdiction of Shanghai Electric Science Research Institute. This standard is drafted by Shanghai Electric Science Research Institute, and Dezhou Hengli Motor Co., Ltd., Jieyang Electric Motor Factory, Guangdong Province, Jiangsu Yuandong Electric Motor Manufacturing Co., Ltd., and Shanghai Pioneer Electric Motor Factory participated in the drafting. The main drafters of this standard are Ma Junpu and Zhang Liangji. This standard was first issued in June 1991. 1 Scope Technical conditions for YH series (IP44) marine three-phase asynchronous motors (frame size 80~355) JB/T5273-2002 This standard specifies the type, basic parameters, technical requirements, test methods, inspection rules, and marking, packaging and transportation requirements of YH series (IP44) marine three-phase asynchronous motors (hereinafter referred to as motors). This standard applies to YH series (IP44) three-phase asynchronous motors (frame size 80-355) used to drive pumps, ventilation machinery, separators, hydraulic machinery and other auxiliary equipment on ships. 2 Normative references The clauses in the following documents become clauses of this standard through reference in this standard. For all dated referenced documents, all subsequent amendments (excluding errata) or revisions are not applicable to this standard. However, parties to an agreement based on this standard are encouraged to study whether the latest versions of these documents can be used. For all undated referenced documents, the latest versions shall apply to this standard. GB/T191—2000 Pictorial symbols for packaging, storage and transportation (eqvISO780:1997) GB/T997—1981 Code for motor structure and installation type (negEC60034-7:1972) GB/T1032—1985 5 Test methods for three-phase asynchronous motors GB/T1993—1993 GB/T19581980 Cooling methods for rotating electrical machines (neqIEC60034-6:1991) Regulations for shape and position tolerance detection GB/ T2423.16—1999 60068-2-10:1988) GB/T2423.17—1993 60068-2-11:1981) GB/T2828—1987 Environmental testing for electric and electronic products Part 2: Test methods: Test J and guidance: Long-term (idt positive C basic environmental testing procedures for electric and electronic products Test Ka: Salt recruitment test method (eqvIEC batch inspection counting sampling procedures and sampling tables (applicable to continuous batch inspection) GB/T 4772.1--1999 (idtIEC60072-1:1991) Dimensions and output power classes of rotating electrical machines Part 1: Frame sizes 56 to 400 and flange sizes 55 to 1080 GB/T4942.1—2001 Classification of protection of rotating electrical machine enclosures (IP code) (idtIEC60034-5:1991) Basic technical requirements for marine rotating electrical machines GB/T70601994 GB10068-2000 60034-14:1996) Measurement, evaluation and limit of mechanical vibration of motors with shaft center height of 56mm and above (idtECGB/T10069.1-—1988 1680-1:1986) GB/T12351—1990||tt| |Determination method and limit of noise of rotating motor Environmental technical requirements for tropical rotating motors JB/T4159—1999 General technical requirements for tropical electrical products Noise engineering determination method (negISO Test method and limit of insulation between turns of formed windings of AC low-voltage motors JB/T5811199I3 JB/T9615.1—2000Test method of insulation between turns of scattered windings of AC low-voltage motors 3 Types, basic parameters and dimensions 3.1 The rated frequency and voltage of the motor are 50Hz, 380V or 60Hz, 440V. 3.2 The rating of the motor is a continuous rating based on the continuous working system (S1). JB/T5273—2002 3.3 Motors with a power of 3kW or less are connected in Y connection, and other power levels are connected in △ connection. 3.4 The structure and installation type of the motor shall be manufactured in accordance with the provisions of Table 1. If the user requires other structures and installation types, they shall comply with the provisions of GB/T997. Frame size 80~225 250~355 Structure and installation type IM1001 (IMB3), IM2001 (IMB35), IM3001 (IMB5), IM3011 (IMV1), IM1002, IM2002IM1001 (IMB3), IM2001 (IMB35), IM3011 (IMV1), IM1002, IM20023.5 The cooling method of the motor is IC411 as specified in GB/T1993-1993.3.6 The enclosure protection grade of the motor is IP44 as specified in GB/T4942.1-2001. The motor should be manufactured according to the following rated power: 3.7 0.55kW.0.75kw.1.1kW.1.5kW.2.2kw.3kW.4kW.5.5kW.7.5kW.11kW.15kW.18.5kw.22kw.30kW37kW.45kW.55kW.75kw.90kW.110kW.132kw.160kW.200kW.250kW.315kw. Note: If the ambient air temperature proposed by the user is different from the provisions of Article 4.2, the changes to the above values can be negotiated by the user and the manufacturer. 3.8 The correspondence between the motor frame number, pole number and power shall comply with the provisions of Table 2. Table 2 Frame number Power kw Frame number Table 2 (continued) Note: S, M, 1 2 in the frame number column represent different powers under the same frame number and pole number. Mathematics after L 1, 2 Electric motor dimensions and tolerances JB/T5273—2002 The installation dimensions and tolerances of the electric motor shall comply with the provisions of Figures 1 to 4 and Tables 3 and 6, and the overall dimensions shall not exceed the specifications of Tables 3 to 6. 3 JB/T5273—2002 G (GB) =D (DA) , GE (GH) limit deviation for frame size 80 is -GE (GH), The rest are The data above the inner mold line of the table are two-pole motors. The data below are four-pole and above motors. The " Table 3 Machine base with feet, end cover " above indicates that there is no data of this specification Flangeless motor and tolerance deviation position JB/T5273—2002 Unit: Dimensions JB/T5273—2002 GE The limit deviation of GH for frame size SO is (G(GB)=D(DA) P size is the maximum limit value. . R is the separation limit from the flange mating surface to the bottom of the shaft extension Table 4 Frame with foot, end cover . The rest is (o "The data above the horizontal line in the table is for two-pole motors. The data below is for four-pole and above motors. The "一" above is the table 6 Mounting dimensions Machine seat number Motor with flange Position seat Machine pressure number 225-355 Basic forging limit Overall dimensions Inspection depth JB/T5273—2002 Unit: mm JB/T5273—2002|| tt||The limit deviation of GD-GE.GE is (10) for frame size 80. The others are (20)P dimension is the maximum limit value, R is the distance from the flange mating surface to the shaft shoulder. F Table 5 Frame without foot, Installation scale The data above the horizontal line in the table are for two-pole motors. The data below are for four-pole and above motors, and the "-" above indicates that there is no data for this specification. Basic Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.