SCS 25.060.10
Machinery Industry Standard of the People's Republic of China
JB/T9943—1999bzxZ.net
Magnetic Grid Linear Displacement Sensor
Published on 1999-05-20
National Machinery Industry Bureau
Technical Conditions
2000-01-01 Implementation
JB/T9943—1999
This standard is based on the basic code of ZBJ42034-89 Silicon Grid Linear Displacement Sensor Technical Conditions. This standard is basically consistent with ZBJ42034-89, with the main differences being: appropriate adjustments have been made to the single and complex indicators; and the relevant regulations have been revised.
This standard replaces ZBJ42 034-89 from the date of implementation. This standard was proposed and drafted by the National Technical Committee for Standardization of Metal Cutting Machine Tools. The responsible drafting unit of this standard is Shanghai Machine Tool Research Institute. The main drafters of this standard are Zhang Lianting and Wang Guqiao. This standard was first issued in June 1989.
Machinery Industry Standard of the People's Republic of China
Magnetic Grid Line Displacement Sensor
Technical Specifications
JB/T9943—J999
B142034--89
Technical Standard specifies the type, basic functions, technical requirements, test methods, inspection rules, marking, packaging and storage of magnetic grid line displacement transducers (hereinafter referred to as magnetic grid sensors). This standard is applicable to linear magnetic pickup sensors and belt-type magnetic grid sensors. 2. Referenced Standards
The provisions contained in the following standards are cited in this standard and constitute the provisions of this standard. The versions shown are valid when this standard is published. All standards are subject to revision, and parties using this standard should explore the possibility of using the latest version of the standard. GO191-1990
Packaging storage and transportation graphic mark
G/T154641995 General technical requirements for color display of effector parts type and basic static data
3. 1 Type,
Magnetic grating sensors have two types:
a) Linear magnetic sensor:
h! Band silicon sensor
3. 2 Not referenced
3.2.1 Effective length L of magnetic scale for recording magnetism See Table 1 Table
Effective length of magnetic scale for recording magnetism
Effective length Engineering
100,151,20n,2.50,309,350.40,459,500.550,600,650 Transformation magnetic period measurement system
Belt type magnetic recording system
National Bureau of Machinery Industry 1999 -05-20 approved700,73,800,9001,1X),1100.1200,1300,1400,1500,1650,1762.1800,190,2000,2200,2400,2600.380,30002400.2600.2800,3000,3200.350040X,5000,60),7000, 8000, 9D0D.1000, 15000,ZU0(Kh, 3)2000-01-01. Actual end
4 anti-technical requirements
4.! Working environment and working conditions
JBT9943-1999
4.1.1 The temperature range of the working environment is 0-45: When the working environment temperature is within 20℃+5, the relative humidity should not be greater than 90%. 4.12 The magnetic field shall not be in contact with weak magnetic fields (such as micro-sensing sockets). 4.2 Appearance and interaction
4.2,! The surface should be free of rust, scratches, plating shedding and other defects, various signs, the number should be correct and clear, 4.2.2 All parts should be firm and stable, and all special parts should be suitable for recording, and there should be no jamming and stagnation. 4.3 Magnetic length
The magnetic length of the magnetic scale should not be less than the provisions in Table 2. Table 2 Magnetic length of the magnetic scale
Accuracy
+14 (add at the end of the effective length) L-50 [add 25 at the end of the effective length of the scale] mm
Accuracy is divided into four levels: The error value of each level is calculated according to the formula in Table 3, and the accuracy is expressed by half of the integer value A with a "±" sign.
Table 3 Grade error
Note: The error refers to the single error between the highest point and the lowest point on the measurement system. The absolute error of the magnetic sensor is not greater than the provisions in Table 4. Error peak-to-peak value
Table 4 Magnetic sensor subdivision error
Period error total
4.6 Repetitiveness
Repetitiveness should not be greater than the current value in Table 5
4.7 Life
JE9943-1999
Table 5 Repetitiveness
#) The measurement stroke of the linear magnetic pickup sensor shall not be less than 2×10m, and the number of movements shall not be less than! ×10\ times: a) The measurement total stroke of the linear magnetic pickup sensor shall not be less than 1×10m, and the number of movements shall not be less than 2×10\ times: 4.% Magnetic head safety
The insulation resistance between the magnetic head core and each cable group shall not be less than 20M. 5 Test method
The test method of the sensor shall be carried out in accordance with relevant regulations. 6 Inspection and testing
Inspection and purchase of magnetic sensors shall be carried out in accordance with relevant regulations. 7 Marking, packaging and storage
7.1 Magnetic sensors shall be marked with:
a) name of the manufacturer;
b) product name and model;
d) product grade;
d) factory serial number and ex-factory date.
7.2 The packaging of the sensor shall include:
a) certificate of conformity;
b) instruction manual;
c) packing list;
d) related accessories.
T.3 Packaging
The packaging shall comply with the provisions of GBT15464, and the packaging storage diagram shall comply with GBT191. 7.4 Storage environment conditions
7.4.1 In the absence of packaging, the storage environment temperature range is 6-459: when the storage environment temperature is within 20T±54., the relative humidity is not greater than 90%
There should be no obvious corrosive gas in the storage environment. 4.2 In the case of packaging, the storage environment temperature range is -25-559: when the storage environment humidity is within 20T±54., the relative humidity is greater than 90%