Some standard content:
ICS65.040.30
Machinery Industry Standard of the People's Republic of China
JB/T10294-2001
Wet pad cooling system
Published on 2001-06-22
China Machinery Industry Federation
Implementation on 2001-10-01
JB/T10294—2001
This standard is one of the greenhouse series standards formulated for the first time. This series of standards includes: 1. Greenhouse structure design load
2. Greenhouse ventilation and cooling design specifications
3. Greenhouse engineering terms
4. Multi-span greenhouse structure
5. Sunlight greenhouse structure
6. Wet curtain cooling device
7. Greenhouse heating system design specifications
8. Greenhouse electrical wiring design specifications
9. Greenhouse control system design specifications
Among the above standards, the first two are national standards, and the rest are industry standards. This standard is a newly formulated industry standard.
This standard is proposed and managed by the National Agricultural Machinery Standardization Technical Committee. The drafting units of this standard are: Environmental Engineering Equipment Research and Development Center of China Agricultural Mechanization Science Research Institute, Key Laboratory of Facility Agriculture Bio-Environment Engineering of China Agricultural University, and Shaanxi Yangling Qinchuan Water-Saving Irrigation Equipment Engineering Co., Ltd. The main drafters of this standard are: Pu Junwen, Wang Li, and Zhang Minqiang. This standard was first issued in June 2001.
1 Scope
Machinery Industry Standard of the People's Republic of China
Wet pad cooling device
Wet pad cooling system
JB/T10294—2001
This standard specifies the terminology, specifications, technical requirements, test methods, inspection rules, marking, packaging, transportation and storage of wet pad cooling devices.
This standard applies to wet pad cooling devices (wet pads are made of paper matrix) used for summer ventilation and cooling of agricultural buildings (greenhouses, livestock and poultry houses). Wet pad cooling devices made of other materials can be implemented as a reference. 2 Referenced standards
The provisions contained in the following standards constitute the provisions of this standard through reference in this standard. When this standard is published, the versions shown are valid. All standards will be revised, and parties using this standard should explore the possibility of using the latest version of the following standards. GB/T18042000
GB/T2828—1997
GB 9969.1—1998
GB/T133061991
3 Terminology
General tolerancesTolerances of linear and angular dimensions without tolerancesBatch inspectionCount sampling procedures and sampling tables (applicable to inspection of continuous batches)Instructions for use of industrial productsGeneral
This standard uses the following terms.
3.1Wet pad cooling systemWet pad cooling systemA system device mainly used for cooling agricultural buildings (greenhouses, livestock and poultry houses) based on the principle of cooling the surrounding air by evaporation of water. The system includes wet pads, frame structures, water supply and distribution pipelines and water pumps. The device is used in conjunction with low-pressure and high-flow fans. 3.2Wet pads
Forming materials used for evaporative cooling. It is made of specially made fiber paper with good water absorption, which is pressed into corrugated boards and then staggered and bonded into a plate shape, allowing airflow and water flow to cross and pass through, and has good anti-corrosion performance. 3.3 Wet pad package The wet pad and the shell that contains the wet pad, maintains the shape of the wet pad and bears the external force during installation, as well as the water distribution pipeline and the outlet. 3.4 Pad face velocity
The wind speed passing through each point in the wet pad (corrugated plate) is variable and difficult to measure. Usually, the wind speed entering or leaving the wet pad, which is easy to measure, is defined as the wind speed passing through the wet pad, referred to as the curtain wind speed. The unit is expressed in m/s. 3.5 Designed curtain wind speed recommended pad face velocity When using a wet pad cooling device for cooling, in order to meet the ventilation volume required for agricultural buildings (greenhouses, livestock and poultry houses), the curtain wind speed value proposed by the manufacturer or design unit is considered to consider the comprehensive factors such as the heat exchange efficiency, resistance loss, and economic applicability of the wet pad area. -Generally 0.5~1.5m/s.
Approved by China Machinery Industry Federation on June 22, 2001, implemented on October 1, 2001
JB/T10294—2001
3.6 Design water supply flow
Recommended calculation rate of the water wet curtain cooling device Under the design wind speed through the curtain, when the system achieves the best heat exchange efficiency, the amount of circulating water supplied by the water pump to the wet curtain per unit area or unit length. The unit is m/(m2·h) or m2/(m·h). It is proposed by the manufacturer or design unit. 3.7 Evaporative cooling heat transfer efficiency refers to the ratio between the actual saturation degree of air passing through the wet curtain and the saturation degree that the air may reach in the ideal process at the designed wind speed. It is numerically equal to the difference in dry bulb temperature before and after the air passes through the wet curtain divided by the difference between the dry bulb temperature and the bulb temperature before the air passes through the wet curtain, that is:
E=-)x100%
(To-Tw)
Where: E—heat transfer efficiency:
T——dry bulb temperature before the wet curtain:
T——dry bulb temperature after the wet curtain:
Twet bulb temperature before the wet curtain.
3.8 Flow resistance static pressure drop refers to the resistance of airflow passing through the wet curtain at the designed wind speed. The unit is Pa. 4 Specifications and models
4.1 Wet curtain dimensions
a) Principles for expressing wet curtain dimensions: thickness in the direction of airflow, height in the vertical section in the direction of airflow, and width in the horizontal section. b) Model specifications are expressed as follows:
口-口×□×口
Wet curtain thickness, mm
Width, mm
Height, mm
Product name
c) Wet curtain thickness series: in mm, the thickness series parameters are 80, 100, 120, 150, 200. d) Wet curtain height series: in mm, the height series parameters are 500, 700, 900, 1100, 1400, 1700, 1900, 2100. e) Wet curtain width series: in mm, the width series parameters are 300, 600, 1000, 1500, 2000. 4.2 Wet curtain box size specifications
a) Wet curtain box size representation principle: the airflow direction is the thickness, the vertical length of the vertical section in the airflow direction when installed vertically is the height, and the horizontal length is the width. b) Model specifications are expressed as follows:
口-口×口×口
Wet curtain box thickness, mm
Wet curtain box width, mm
Wet curtain box height, mm
Product name
JB/T10294—2001
Wet curtain box thickness series: in mm, the thickness series parameters are 80, 100, 120, 150, 200. d) Wet curtain box height series: in mm, the height series parameters are 600, 800, 1000, 1200, 1500, 1800, 2000, 2200.
e) Wet curtain box width series: in mm, the width series parameters are 1000, 1200, 1500, 2000. 5 Technical requirements
5.1 Basic requirements
5.1.1 The wet curtain cooling device shall be manufactured according to the drawings and technical documents approved by the prescribed procedures. 5.1.2 The external dimensions of the wet curtain and the dimensions of the wet curtain box shall comply with the provisions of 4.1 and 4.2. 5.1.3 The materials such as plates, pipes and pipe fittings used in the wet curtain cooling device and the water pump shall comply with the provisions of the relevant standards. 5.1.4 The evaporative cooling heat exchange efficiency-wind speed characteristic curve and the flow resistance loss-wind speed characteristic curve of the wet curtain material shall be given in the instruction manual of the wet curtain cooling device.
5.2 Appearance requirements
The surface of the wet curtain box is not allowed to have obvious collision damage. 5.2.1
5.2.2 The stacking and wave pattern of the wet curtain material should be uniform. No obvious adhesive accumulation is allowed on the wet curtain surface. 5.2.3
5.2.4 No obvious local defects of the wet curtain material, such as tearing, degumming and dents, are allowed. The wet curtain and the box frame are tightly crimped without leaving any gaps. 5.2.5
5.3 Dimension requirements
The tolerance grade of the width, height and thickness of the wet curtain box shall not be lower than the requirements of Class C in GB/T1804. 5.4 Performance requirements
5.4.1 The evaporative cooling heat exchange efficiency and flow resistance loss under the design wind speed over the curtain shall comply with the provisions of Table 1. Table 1 Evaporative cooling heat exchange efficiency and flow resistance of wet curtain cooling device under the design wind speed over the curtain Technical performance
Evaporative cooling heat exchange efficiency E
Flow resistance
5.4.2 General performance
Technical parameters
After the wet curtain is completely soaked, it is not allowed to have defects such as material collapse and holes. 5.4.2.1
5.4.2.2 During the installation and use of the wet curtain box, dry strips that have not been flowed by water are not allowed to appear on the wet curtain, and concentrated water flow is not allowed on the inner and outer surfaces of the wet curtain.
5.4.2.3 Water leakage is not allowed in the water supply, distribution and return pipelines of the wet curtain cooling device. 5.4.3 Vibration resistance
After the vibration test, the wet curtain cooling device shall not have debonding, tearing, displacement from the wet curtain box assembly or other damage. 5.4.4 The service life of the wet curtain cooling device should be greater than 4 years during normal use. 6 Test method
6.1 Appearance inspection
JB/T10294—2001
The appearance inspection should be carried out visually under normal illumination in accordance with the requirements of 5.2. 6.2 Dimension inspection
The length dimension is measured with a length measuring tool with an accuracy of 1mm. 6.3 Evaporative cooling efficiency, flow resistance
6.3.1 Test conditions
6.3.1.1 In the laboratory wind tunnel, the wind speed over the curtain is ≤2.5m/s, the thickness of the wet curtain is 80~250mm, and the wet curtain is supplied with water at the designed water supply flow rate to make the wet curtain completely wet.
6.3.1.2 Field test conditions: In agricultural buildings (greenhouses, livestock and poultry houses), the wet curtains are newly installed and used for no more than 30 days. At the designed wind speed over the curtain, the wet curtains are supplied with water at the designed water supply flow rate to make the wet curtains completely soaked. 6.3.1.3 Climate parameters during the test: sunny day, outdoor dry bulb temperature greater than 28°C, relative humidity less than 70%6.3.1.4 Test time: 10:00 am to 3:00 pm.6.3.2 Performance test method
6.3.2.1 Evaporative cooling heat exchange efficiency
a) The measurement section is parallel to the wet curtain. It is divided into the outdoor side of the wet curtain and the indoor side of the wet curtain, and the distance from the wet curtain is 0.5m. b) The measurement point is selected in the middle of the wet curtain distribution surface, and more than five points should be selected. Measure the air dry bulb temperature and wet bulb temperature outside the wet curtain room; measure the air dry bulb temperature and wind speed inside the wet curtain room, and take the average value for calculation. c) During the laboratory wind tunnel test, the speed-adjustable fan can provide a wind speed of 0.5~2.5m/s through the curtain, and the maximum wind speed through the curtain can reach 2.5m/s. During the on-site test, the wind speed adopts the designed wind speed through the curtain.
d) Calculate the evaporative cooling heat exchange efficiency at different wind speeds through the curtain, and draw the evaporative cooling heat exchange efficiency-wind speed characteristic curve. The evaporative cooling heat exchange efficiency is calculated according to the formula in 3.7.
6.3.2.2 Flow resistance
Use a micromanometer to measure the flow resistance at different wind speeds outside and inside the wet curtain room, and draw the flow resistance-wind speed characteristic curve. 6.3.3 The test instruments shall comply with the provisions of Table 2. Table 2 Test instruments
Measurement parameters
Measuring instruments
Glass mercury thermometer
Thermocouple thermometer
Wet and dry bulb thermometer
Micromanometer (inclined, compensated or automatic sensing type) Anemometer
General performance test
Measurement items
Inside and outside of wet curtain
Wet and dry bulb temperature
Air static pressure
Wind speed inside and outside of wet curtain
Use the field test method to supply water to the wet curtain cooling device with the rated water supply flow rate and test according to the requirements of 5.4.2. 6.5 Vibration resistance test
Instrument accuracy
After the wet curtain cooling device passes the inspection, it shall be packaged according to the regulations, placed in the middle of the truck and fixed. The load of the truck shall not exceed 1/3 of its rated load. It shall travel 100 km on a Class 3 road surface at a speed of 20~40 km/h. The wet curtain cooling device after the transportation test shall be re-inspected according to the requirements of 5.4.3.
Inspection rules
Inspection items
JB/T10294—2001
Any item that does not meet the requirements of this standard shall be deemed unqualified. 7.1. 2
According to the degree of influence on product quality, it shall be divided into Class A unqualified and Class B unqualified. The classification of unqualified items is shown in Table 3. Table 3 Unqualified classification
Unqualified classification
Sampling method
Obvious collision damage
Wet curtain flow resistance
Wet curtain evaporative cooling heat exchange efficiency
Partial defect of wet curtain material
Wet curtain collapses and holes after being soaked
Marking, packaging
Obvious adhesive accumulation on the surface of wet curtain material
Water supply, water distribution, return water leakage
Wet curtain and frame crimping tightness
Wet curtain lamination and waveform uniformity
Vibration resistance
Dry band and concentrated water flow during use
7.2.1 According to GB/T2828, randomly select products produced in the factory in the last six months. The sample size is 2 sets. The product inspection batch shall not be less than 16 units. There is no batch limit when sampling by users and the market, but the products shall be newly installed and used for no more than 30 days. 7.2.2 When the ordering unit samples the product quality, it can be carried out in accordance with the provisions of GB/T2828. The qualified quality level and inspection batch shall be determined by negotiation between the supplier and the ordering party. If the contract stipulates, it shall be carried out in accordance with the contract. 7.2.3 For the factory inspection of products, enterprises can exempt or reduce the inspection of performance items according to their own product quality level. 7.3 Judgment rules
Apply item by item assessment and judge by category. The product quality judgment scheme is shown in Table 4. Table 4 Product quality judgment scheme
Unqualified classification
Sampling scheme
Qualified products
Inspection level
Sample code
Number of samples n
8 Marking, packaging, transportation and storage
8.1 Marking
JB/T10294—2001
The sign of the wet curtain cooling device should be fixed in a conspicuous position. The form, size and technical requirements of the sign should comply with the provisions of GB/T13306. Its contents include:
a) Product model and name:
b) Product standard number and trademark;
c) Main technical parameters;
d) Manufacturer’s name and address:
e) Factory number and date.
8.2 Packaging
8.2.1 The water distribution pipe inlet and outlet of the wet curtain box should be protected from the entry of debris. 8.2.2 According to the storage and transportation conditions of the wet curtain box, a firm packaging type should be used to ensure that the wet curtain material and the box are not collided or damaged. 8.2.3 The following documents should be included in the packaging box:
a) Product certificate:
b) Product instruction manual, which should comply with the relevant provisions of GB9969.1:c) Packing list;
d) List of accessories, spare parts, and random tools; e) User opinion survey form.
8.3 Transportation and storage
8.3.1 During transportation, the product should not be collided or squeezed. 2 The product should be stored in a ventilated and dry warehouse or canopy to prevent damage from collision and corrosion from corrosive gases. 8.3.2
Mechanical Industry Standard
Wet Curtain Cooling Device
JB/T10294—2001
Published by the Mechanical Science Research Institute
Printed by the Mechanical Science Research Institute
(No. 2, Shouti South Road, Beijing: Postal Code 100044)*
Format 880X12301/16 Printing sheet 3/4
4 Word count 14.000
First edition in September 2001
First printing in September 2001
Print run 1-500
Price 1200 yuan
2001-135
Mechanical Industry Standard Service Network: http/AvwwJB.ac.cn3 Water leakage is not allowed in the water supply, distribution and return pipes of the wet curtain cooling device. 5.4.3 Vibration resistance
After the vibration test of the wet curtain cooling device, the wet curtain shall not be debonded, torn, displaced from the wet curtain box assembly or other damage. 5.4.4 The service life of the wet curtain cooling device should be more than 4 years during normal use. 6 Test method
6.1 Appearance inspection
JB/T10294—2001
The appearance inspection should be carried out visually under normal illumination in accordance with the requirements of 5.2. 6.2 Dimension inspection
The length dimension is measured with a length measuring tool with an accuracy of 1mm. 6.3 Evaporative cooling efficiency and flow resistance
6.3.1 Test conditions
6.3.1.1 In the test room wind tunnel, the wind speed over the curtain is ≤2.5m/s, the thickness of the wet curtain is 80~250mm, and the wet curtain is supplied with water at the designed water supply flow rate to make the wet curtain completely soaked.
6.3.1.2 Field test conditions: In agricultural buildings (greenhouses, livestock and poultry houses), the wet curtain is newly installed and used for no more than 30 days. At the designed wind speed over the curtain, the wet curtain is supplied with water at the designed water supply flow rate to make the wet curtain completely soaked. 6.3.1.3 Climate parameters during the test: sunny day, outdoor dry bulb temperature greater than 28℃, relative humidity less than 70% 6.3.1.4 Test time: 10:00 am to 3:00 pm. 6.3.2 Performance test method
6.3.2.1 Evaporative cooling heat exchange efficiency
a) The measurement section is parallel to the wet curtain. Divide into the outdoor side of the wet curtain and the indoor side of the wet curtain, 0.5m away from the wet curtain. b) The measurement point is selected in the middle of the wet curtain distribution surface, and more than five points should be selected. Measure the air dry bulb temperature and wet bulb temperature outside the wet curtain; measure the air dry bulb temperature and wind speed inside the wet curtain, and take the average value when calculating. c) During the laboratory wind tunnel test, the speed-adjustable fan can provide 0.5~2.5m/s wind speed through the curtain, and the maximum wind speed through the curtain can reach 2.5m/s. The wind speed during the on-site test uses the designed wind speed through the curtain.
d) Calculate the evaporative cooling heat exchange efficiency under different wind speeds through the curtain, and draw the evaporative cooling heat exchange efficiency-wind speed characteristic curve. The evaporative cooling heat exchange efficiency is calculated according to the formula in 3.7.
6.3.2.2 Flow resistance
Use a micromanometer to measure the flow resistance under different wind speeds outside and inside the wet curtain, and draw the flow resistance-wind speed characteristic curve. 6.3.3 The test instruments should comply with the provisions of Table 2. Table 2 Test instruments
Measurement parameters
Measuring instruments
Glass mercury thermometer
Thermocouple thermometer
Wet and dry bulb thermometer
Micromanometer (inclined, compensated or automatic sensing type) Anemometer
General performance test
Measurement items
Inside and outside of wet curtain
Wet and dry bulb temperature
Air static pressure
Wind speed inside and outside of wet curtain
Use the field test method to supply water to the wet curtain cooling device with the rated water supply flow rate and test according to the requirements of 5.4.2. 6.5 Vibration resistance test
Instrument accuracy
After the wet curtain cooling device passes the inspection, it shall be packaged according to the regulations, placed in the middle of the truck and fixed. The load of the truck shall not exceed 1/3 of its rated load. It shall travel 100 km on a Class 3 road surface at a speed of 20~40 km/h. The wet curtain cooling device after the transportation test shall be re-inspected according to the requirements of 5.4.3.
Inspection rules
Inspection items
JB/T10294—2001
Any item that does not meet the requirements of this standard shall be deemed unqualified. 7.1. 2
According to the degree of influence on product quality, it shall be divided into Class A unqualified and Class B unqualified. The classification of unqualified items is shown in Table 3. Table 3 Unqualified classification
Unqualified classification
Sampling method
Obvious collision damage
Wet curtain flow resistance
Wet curtain evaporative cooling heat exchange efficiency
Partial defect of wet curtain material
Wet curtain collapses and holes after being soaked
Marking, packaging
Obvious adhesive accumulation on the surface of wet curtain material
Water supply, water distribution, return water leakage
Wet curtain and frame crimping tightness
Wet curtain lamination and waveform uniformity
Vibration resistance
Dry band and concentrated water flow during use
7.2.1 According to GB/T2828, randomly select products produced in the factory in the last six months. The sample size is 2 sets. The product inspection batch shall not be less than 16 units. There is no batch limit when sampling by users and the market, but the products shall be newly installed and used for no more than 30 days. 7.2.2 When the ordering unit samples the product quality, it can be carried out in accordance with the provisions of GB/T2828. The qualified quality level and inspection batch shall be determined by negotiation between the supplier and the ordering party. If the contract stipulates, it shall be carried out in accordance with the contract. 7.2.3 For the factory inspection of products, enterprises can exempt or reduce the inspection of performance items according to their own product quality level. 7.3 Judgment rules
Apply item by item assessment and judge by category. The product quality judgment scheme is shown in Table 4. Table 4 Product quality judgment scheme
Unqualified classification
Sampling scheme
Qualified products
Inspection level
Sample code
Number of samples n
8 Marking, packaging, transportation and storage
8.1 Marking
JB/T10294—2001
The sign of the wet curtain cooling device should be fixed in a conspicuous position. The form, size and technical requirements of the sign should comply with the provisions of GB/T13306. Its contents include:
a) Product model and name:
b) Product standard number and trademark;
c) Main technical parameters;
d) Manufacturer’s name and address:
e) Factory number and date.
8.2 PackagingbzxZ.net
8.2.1 The water distribution pipe inlet and outlet of the wet curtain box should be protected from the entry of debris. 8.2.2 According to the storage and transportation conditions of the wet curtain box, a firm packaging type should be used to ensure that the wet curtain material and the box are not collided or damaged. 8.2.3 The following documents should be included in the packaging box:
a) Product certificate:
b) Product instruction manual, which should comply with the relevant provisions of GB9969.1:c) Packing list;
d) List of accessories, spare parts, and random tools; e) User opinion survey form.
8.3 Transportation and storage
8.3.1 During transportation, the product should not be collided or squeezed. 2 The product should be stored in a ventilated and dry warehouse or canopy to prevent damage from collision and corrosion from corrosive gases. 8.3.2
Mechanical Industry Standard
Wet Curtain Cooling Device
JB/T10294—2001
Published by the Mechanical Science Research Institute
Printed by the Mechanical Science Research Institute
(No. 2, Shouti South Road, Beijing: Postal Code 100044)*
Format 880X12301/16 Printing sheet 3/4
4 Word count 14.000
First edition in September 2001
First printing in September 2001
Print run 1-500
Price 1200 yuan
2001-135
Mechanical Industry Standard Service Network: http/AvwwJB.ac.cn3 Water leakage is not allowed in the water supply, distribution and return pipes of the wet curtain cooling device. 5.4.3 Vibration resistance
After the vibration test of the wet curtain cooling device, the wet curtain shall not be debonded, torn, displaced from the wet curtain box assembly or other damage. 5.4.4 The service life of the wet curtain cooling device should be more than 4 years during normal use. 6 Test method
6.1 Appearance inspection
JB/T10294—2001
The appearance inspection should be carried out visually under normal illumination in accordance with the requirements of 5.2. 6.2 Dimension inspection
The length dimension is measured with a length measuring tool with an accuracy of 1mm. 6.3 Evaporative cooling efficiency and flow resistance
6.3.1 Test conditions
6.3.1.1 In the test room wind tunnel, the wind speed over the curtain is ≤2.5m/s, the thickness of the wet curtain is 80~250mm, and the wet curtain is supplied with water at the designed water supply flow rate to make the wet curtain completely soaked.
6.3.1.2 Field test conditions: In agricultural buildings (greenhouses, livestock and poultry houses), the wet curtain is newly installed and used for no more than 30 days. At the designed wind speed over the curtain, the wet curtain is supplied with water at the designed water supply flow rate to make the wet curtain completely soaked. 6.3.1.3 Climate parameters during the test: sunny day, outdoor dry bulb temperature greater than 28℃, relative humidity less than 70% 6.3.1.4 Test time: 10:00 am to 3:00 pm. 6.3.2 Performance test method
6.3.2.1 Evaporative cooling heat exchange efficiency
a) The measurement section is parallel to the wet curtain. Divide into the outdoor side of the wet curtain and the indoor side of the wet curtain, 0.5m away from the wet curtain. b) The measurement point is selected in the middle of the wet curtain distribution surface, and more than five points should be selected. Measure the air dry bulb temperature and wet bulb temperature outside the wet curtain; measure the air dry bulb temperature and wind speed inside the wet curtain, and take the average value when calculating. c) During the laboratory wind tunnel test, the speed-adjustable fan can provide 0.5~2.5m/s wind speed through the curtain, and the maximum wind speed through the curtain can reach 2.5m/s. The wind speed during the on-site test uses the designed wind speed through the curtain.
d) Calculate the evaporative cooling heat exchange efficiency under different wind speeds through the curtain, and draw the evaporative cooling heat exchange efficiency-wind speed characteristic curve. The evaporative cooling heat exchange efficiency is calculated according to the formula in 3.7.
6.3.2.2 Flow resistance
Use a micromanometer to measure the flow resistance under different wind speeds outside and inside the wet curtain, and draw the flow resistance-wind speed characteristic curve. 6.3.3 The test instruments should comply with the provisions of Table 2. Table 2 Test instruments
Measurement parameters
Measuring instruments
Glass mercury thermometer
Thermocouple thermometer
Wet and dry bulb thermometer
Micromanometer (inclined, compensated or automatic sensing type) Anemometer
General performance test
Measurement items
Inside and outside of wet curtain
Wet and dry bulb temperature
Air static pressure
Wind speed inside and outside of wet curtain
Use the field test method to supply water to the wet curtain cooling device with the rated water supply flow rate and test according to the requirements of 5.4.2. 6.5 Vibration resistance test
Instrument accuracy
After the wet curtain cooling device passes the inspection, it shall be packaged according to the regulations, placed in the middle of the truck and fixed. The load of the truck shall not exceed 1/3 of its rated load. It shall travel 100 km on a Class 3 road surface at a speed of 20~40 km/h. The wet curtain cooling device after the transportation test shall be re-inspected according to the requirements of 5.4.3.
Inspection rules
Inspection items
JB/T10294—2001
Any item that does not meet the requirements of this standard shall be deemed unqualified. 7.1. 2
According to the degree of influence on product quality, it shall be divided into Class A unqualified and Class B unqualified. The classification of unqualified items is shown in Table 3. Table 3 Unqualified classification
Unqualified classification
Sampling method
Obvious collision damage
Wet curtain flow resistance
Wet curtain evaporative cooling heat exchange efficiency
Partial defect of wet curtain material
Wet curtain collapses and holes after being soaked
Marking, packaging
Obvious adhesive accumulation on the surface of wet curtain material
Water supply, water distribution, return water leakage
Wet curtain and frame crimping tightness
Wet curtain lamination and waveform uniformity
Vibration resistance
Dry band and concentrated water flow during use
7.2.1 According to GB/T2828, randomly select products produced in the factory in the last six months. The sample size is 2 sets. The product inspection batch shall not be less than 16 units. There is no batch limit when sampling by users and the market, but the products shall be newly installed and used for no more than 30 days. 7.2.2 When the ordering unit samples the product quality, it can be carried out in accordance with the provisions of GB/T2828. The qualified quality level and inspection batch shall be determined by negotiation between the supplier and the ordering party. If the contract stipulates, it shall be carried out in accordance with the contract. 7.2.3 For the factory inspection of products, enterprises can exempt or reduce the inspection of performance items according to their own product quality level. 7.3 Judgment rules
Apply item by item assessment and judge by category. The product quality judgment scheme is shown in Table 4. Table 4 Product quality judgment scheme
Unqualified classification
Sampling scheme
Qualified products
Inspection level
Sample code
Number of samples n
8 Marking, packaging, transportation and storage
8.1 Marking
JB/T10294—2001
The sign of the wet curtain cooling device should be fixed in a conspicuous position. The form, size and technical requirements of the sign should comply with the provisions of GB/T13306. Its contents include:
a) Product model and name:
b) Product standard number and trademark;
c) Main technical parameters;
d) Manufacturer’s name and address:
e) Factory number and date.
8.2 Packaging
8.2.1 The water distribution pipe inlet and outlet of the wet curtain box should be protected from the entry of debris. 8.2.2 According to the storage and transportation conditions of the wet curtain box, a firm packaging type should be used to ensure that the wet curtain material and the box are not collided or damaged. 8.2.3 The following documents should be included in the packaging box:
a) Product certificate:
b) Product instruction manual, which should comply with the relevant provisions of GB9969.1:c) Packing list;
d) List of accessories, spare parts, and random tools; e) User opinion survey form.
8.3 Transportation and storage
8.3.1 During transportation, the product should not be collided or squeezed. 2 The product should be stored in a ventilated and dry warehouse or canopy to prevent damage from collision and corrosion from corrosive gases. 8.3.2
Mechanical Industry Standard
Wet Curtain Cooling Device
JB/T10294—2001
Published by the Mechanical Science Research Institute
Printed by the Mechanical Science Research Institute
(No. 2, Shouti South Road, Beijing: Postal Code 100044)*
Format 880X12301/16 Printing sheet 3/4
4 Word count 14.000
First edition in September 2001
First printing in September 2001
Print run 1-500
Price 1200 yuan
2001-135
Mechanical Industry Standard Service Network: http/AvwwJB.ac.cn1 Evaporative cooling heat exchange efficiency
a) The measurement section is parallel to the wet curtain. It is divided into the outdoor outside of the wet curtain and the indoor inside of the wet curtain, and the distance from the wet curtain is 0.5m. b) The measurement point is selected in the middle of the wet curtain distribution surface, and more than five points should be selected. Measure the air dry bulb temperature and wet bulb temperature outside the wet curtain; measure the air dry bulb temperature and wind speed inside the wet curtain, and take the average value when calculating. c) During the laboratory wind tunnel test, the speed-adjustable fan can provide a wind speed of 0.5~2.5m/s through the curtain, and the maximum wind speed through the curtain can reach 2.5m/s. The wind speed during the on-site test uses the designed wind speed through the curtain.
d) Calculate the evaporative cooling heat exchange efficiency under different wind speeds through the curtain, and draw the evaporative cooling heat exchange efficiency-wind speed characteristic curve. The evaporative cooling heat exchange efficiency is calculated according to the formula in 3.7.
6.3.2.2 Flow resistance
Use a micromanometer to measure the flow resistance at different wind speeds on the outdoor and indoor sides of the wet curtain, and draw a flow resistance-wind speed characteristic curve. 6.3.3 The test instruments shall comply with the provisions of Table 2. Table 2 Test instruments
Measurement parameters
Measurement instruments
Glass mercury thermometer
Thermocouple thermometer
Dry and wet bulb thermometer
Micromanometer (inclined, compensated or automatic sensing type) Anemometer
General performance test
Measurement items
Inside and outside of wet curtain
Dry and wet bulb temperature
Air static pressure
Inside and outside of wet curtain wind speed
Use the on-site test method to supply water to the wet curtain cooling device at the rated water supply flow rate and test according to the requirements of 5.4.2. 6.5 Vibration resistance test
Instrument accuracy
After the wet curtain cooling device passes the inspection, it shall be packaged according to the regulations, placed in the middle of the truck and fixed. The load of the truck shall not exceed 1/3 of its rated load. It shall travel 100 km on a Class 3 road surface at a speed of 20~40 km/h. The wet curtain cooling device after the transportation test shall be re-inspected according to the requirements of 5.4.3.
Inspection rules
Inspection items
JB/T10294—2001
Any item that does not meet the requirements of this standard shall be deemed unqualified. 7.1. 2
According to the degree of influence on product quality, it shall be divided into Class A unqualified and Class B unqualified. The classification of unqualified items is shown in Table 3. Table 3 Unqualified classification
Unqualified classification
Sampling method
Obvious collision damage
Wet curtain flow resistance
Wet curtain evaporative cooling heat exchange efficiency
Partial defect of wet curtain material
Wet curtain collapses and holes after being soaked
Marking, packaging
Obvious adhesive accumulation on the surface of wet curtain material
Water supply, water distribution, return water leakage
Wet curtain and frame crimping tightness
Wet curtain lamination and waveform uniformity
Vibration resistance
Dry band and concentrated water flow during use
7.2.1 According to GB/T2828, randomly select products produced in the factory in the last six months. The sample size is 2 sets. The product inspection batch shall not be less than 16 units. There is no batch limit when sampling by users and the market, but the products shall be newly installed and used for no more than 30 days. 7.2.2 When the ordering unit samples the product quality, it can be carried out in accordance with the provisions of GB/T2828. The qualified quality level and inspection batch shall be determined by negotiation between the supplier and the ordering party. If the contract stipulates, it shall be carried out in accordance with the contract. 7.2.3 For the factory inspection of products, enterprises can exempt or reduce the inspection of performance items according to their own product quality level. 7.3 Judgment rules
Apply item by item assessment and judge by category. The product quality judgment scheme is shown in Table 4. Table 4 Product quality judgment scheme
Unqualified classification
Sampling scheme
Qualified products
Inspection level
Sample code
Number of samples n
8 Marking, packaging, transportation and storage
8.1 Marking
JB/T10294—2001
The sign of the wet curtain cooling device should be fixed in a conspicuous position. The form, size and technical requirements of the sign should comply with the provisions of GB/T13306. Its contents include:
a) Product model and name:
b) Product standard number and trademark;
c) Main technical parameters;
d) Manufacturer’s name and address:
e) Factory number and date.
8.2 Packaging
8.2.1 The water distribution pipe inlet and outlet of the wet curtain box should be protected from the entry of debris. 8.2.2 According to the storage and transportation conditions of the wet curtain box, a firm packaging type should be used to ensure that the wet curtain material and the box are not collided or damaged. 8.2.3 The following documents should be included in the packaging box:
a) Product certificate:
b) Product instruction manual, which should comply with the relevant provisions of GB9969.1:c) Packing list;
d) List of accessories, spare parts, and random tools; e) User opinion survey form.
8.3 Transportation and storage
8.3.1 During transportation, the product should not be collided or squeezed. 2 The product should be stored in a ventilated and dry warehouse or canopy to prevent damage from collision and corrosion from corrosive gases. 8.3.2
Mechanical Industry Standard
Wet Curtain Cooling Device
JB/T10294—2001
Published by the Mechanical Science Research Institute
Printed by the Mechanical Science Research Institute
(No. 2, Shouti South Road, Beijing: Postal Code 100044)*
Format 880X12301/16 Printing sheet 3/4
4 Word count 14.000
First edition in September 2001
First printing in September 2001
Print run 1-500
Price 1200 yuan
2001-135
Mechanical Industry Standard Service Network: http/AvwwJB.ac.cn1 Evaporative cooling heat exchange efficiency
a) The measurement section is parallel to the wet curtain. It is divided into the outdoor outside of the wet curtain and the indoor inside of the wet curtain, and the distance from the wet curtain is 0.5m. b) The measurement point is selected in the middle of the wet curtain distribution surface, and more than five points should be selected. Measure the air dry bulb temperature and wet bulb temperature outside the wet curtain; measure the air dry bulb temperature and wind speed inside the wet curtain, and take the average value when calculating. c) During the laboratory wind tunnel test, the speed-adjustable fan can provide a wind speed of 0.5~2.5m/s through the curtain, and the maximum wind speed through the curtain can reach 2.5m/s. The wind speed during the on-site test uses the designed wind speed through the curtain.
d) Calculate the evaporative cooling heat exchange efficiency under different wind speeds through the curtain, and draw the evaporative cooling heat exchange efficiency-wind speed characteristic curve. The evaporative cooling heat exchange efficiency is calculated according to the formula in 3.7.
6.3.2.2 Flow resistance
Use a micromanometer to measure the flow resistance at different wind speeds on the outdoor and indoor sides of the wet curtain, and draw a flow resistance-wind speed characteristic curve. 6.3.3 The test instruments shall comply with the provisions of Table 2. Table 2 Test instruments
Measurement parameters
Measurement instruments
Glass mercury thermometer
Thermocouple thermometer
Dry and wet bulb thermometer
Micromanometer (inclined, compensated or automatic sensing type) Anemometer
General performance test
Measurement items
Inside and outside of wet curtain
Dry and wet bulb temperature
Air static pressure
Inside and outside of wet curtain wind speed
Use the on-site test method to supply water to the wet curtain cooling device at the rated water supply flow rate and test according to the requirements of 5.4.2. 6.5 Vibration resistance test
Instrument accuracy
After the wet curtain cooling device passes the inspection, it shall be packaged according to the regulations, placed in the middle of the truck and fixed. The load of the truck shall not exceed 1/3 of its rated load. It shall travel 100 km on a Class 3 road surface at a speed of 20~40 km/h. The wet curtain cooling device after the transportation test shall be re-inspected according to the requirements of 5.4.3.
Inspection rules
Inspection items
JB/T10294—2001
Any item that does not meet the requirements of this standard shall be deemed unqualified. 7.1. 2
According to the degree of influence on product quality, it shall be divided into Class A unqualified and Class B unqualified. The classification of unqualified items is shown in Table 3. Table 3 Unqualified classification
Unqualified classification
Sampling method
Obvious collision damage
Wet curtain flow resistance
Wet curtain evaporative cooling heat exchange efficiency
Partial defect of wet curtain material
Wet curtain collapses and holes after being soaked
Marking, packaging
Obvious adhesive accumulation on the surface of wet curtain material
Water supply, water distribution, return water leakage
Wet curtain and frame crimping tightness
Wet curtain lamination and waveform uniformity
Vibration resistance
Dry band and concentrated water flow during use
7.2.1 According to GB/T2828, randomly select products produced in the factory in the last six months. The sample size is 2 sets. The product inspection batch shall not be less than 16 units. There is no batch limit when sampling by users and the market, but the products shall be newly installed and used for no more than 30 days. 7.2.2 When the ordering unit samples the product quality, it can be carried out in accordance with the provisions of GB/T2828. The qualified quality level and inspection batch shall be determined by negotiation between the supplier and the ordering party. If the contract stipulates, it shall be carried out in accordance with the contract. 7.2.3 For the factory inspection of products, enterprises can exempt or reduce the inspection of performance items according to their own product quality level. 7.3 Judgment rules
Apply item by item assessment and judge by category. The product quality judgment scheme is shown in Table 4. Table 4 Product quality judgment scheme
Unqualified classification
Sampling scheme
Qualified products
Inspection level
Sample code
Number of samples n
8 Marking, packaging, transportation and storage
8.1 Marking
JB/T10294—2001
The sign of the wet curtain cooling device should be fixed in a conspicuous position. The form, size and technical requirements of the sign should comply with the provisions of GB/T13306. Its contents include:
a) Product model and name:
b) Product standard number and trademark;
c) Main technical parameters;
d) Manufacturer’s name and address:
e) Factory number and date.
8.2 Packaging
8.2.1 The water distribution pipe inlet and outlet of the wet curtain box should be protected from the entry of debris. 8.2.2 According to the storage and transportation conditions of the wet curtain box, a firm packaging type should be used to ensure that the wet curtain material and the box are not collided or damaged. 8.2.3 The following documents should be included in the packaging box:
a) Product certificate:
b) Product instruction manual, which should comply with the relevant provisions of GB9969.1:c) Packing list;
d) List of accessories, spare parts, and random tools; e) User opinion survey form.
8.3 Transportation and storage
8.3.1 During transportation, the product should not be collided or squeezed. 2 The product should be stored in a ventilated and dry warehouse or canopy to prevent damage from collision and corrosion from corrosive gases. 8.3.2
Mechanical Industry Standard
Wet Curtain Cooling Device
JB/T10294—2001
Published by the Mechanical Science Research Institute
Printed by the Mechanical Science Research Institute
(No. 2, Shouti South Road, Beijing: Postal Code 100044)*
Format 880X12301/16 Printing sheet 3/4
4 Word count 14.000
First edition in September 2001
First printing in September 2001
Print run 1-500
Price 1200 yuan
2001-135
Mechanical Industry Standard Service Network: http/AvwwJB.ac.cn1 According to GB/T2828, the products produced in the factory in the last six months are randomly selected. The sample size is 2 units. The product inspection batch is not less than 16 units. There is no batch limit when sampling users and markets, but it should be a newly installed product that has not been used for more than 30 days. 7.2.2 When the ordering unit samples the product quality, it can be carried out in accordance with the provisions of GB/T2828. The qualified quality level and inspection batch are determined by negotiation between the supplier and the ordering party. If the contract stipulates, it shall be carried out in accordance with the contract. 7.2.3 For the factory inspection of products, enterprises can exempt or reduce the inspection of performance items according to their own product quality level. 7.3 Judgment rules
Adopt item-by-item assessment and judgment by category. The product quality judgment plan is shown in Table 4. Table 4 Product quality judgment scheme
Unqualified classification
Sampling scheme
Qualified products
Inspection level
Sample code
Number of samples n
8 Marking, packaging, transportation and storage
8.1 Marking
JB/T10294—2001
The sign of the wet curtain cooling device should be fixed in a conspicuous position. The form, size and technical requirements of the sign should comply with the provisions of GB/T13306. Its contents include:
a) Product model and name:
b) Product standard number and trademark;
c) Main technical parameters;
d) Manufacturer’s name and address:
e) Factory number and date.
8.2 Packaging
8.2.1 The water distribution pipe inlet and outlet of the wet curtain box should be protected from the entry of debris. 8.2.2 According to the storage and transportation conditions of the wet curtain box, a firm packaging type should be used to ensure that the wet curtain material and the box are not collided or damaged. 8.2.3 The following documents should be included in the packaging box:
a) Product certificate:
b) Product instruction manual, which should comply with the relevant provisions of GB9969.1:c) Packing list;
d) List of accessories, spare parts, and random tools; e) User opinion survey form.
8.3 Transportation and storage
8.3.1 During transportation, the product should not be collided or squeezed. 2 The product should be stored in a ventilated and dry warehouse or canopy to prevent damage from collision and corrosion from corrosive gases. 8.3.2
Mechanical Industry Standard
Wet Curtain Cooling Device
JB/T10294—2001
Published by the Mechanical Science Research Institute
Printed by the Mechanical Science Research Institute
(No. 2, Shouti South Road, Beijing: Postal Code 100044)*
Format 880X12301/16 Printing sheet 3/4
4 Word count 14.000
First edition in September 2001
First printing in September 2001
Print run 1-500
Price 1200 yuan
2001-135
Mechanical Industry Standard Service Network: http/AvwwJB.ac.cn1 According to GB/T2828, the products produced in the factory in the last six months are randomly selected. The sample size is 2 units. The product inspection batch is not less than 16 units. There is no batch limit when sampling users and markets, but it should be a newly installed product that has not been used for more than 30 days. 7.2.2 When the ordering unit samples the product quality, it can be carried out in accordance with the provisions of GB/T2828. The qualified quality level and inspection batch are determined by negotiation between the supplier and the ordering party. If the contract stipulates, it shall be carried out in accordance with the contract. 7.2.3 For the factory inspection of products, enterprises can exempt or reduce the inspection of performance items according to their own product quality level. 7.3 Judgment rules
Adopt item-by-item assessment and judgment by category. The product quality judgment plan is shown in Table 4. Table 4 Product quality judgment scheme
Unqualified classification
Sampling scheme
Qualified products
Inspection level
Sample code
Number of samples n
8 Marking, packaging, transportation and storage
8.1 Marking
JB/T10294—2001
The sign of the wet curtain cooling device should be fixed in a conspicuous position. The form, size and technical requirements of the sign should comply with the provisions of GB/T13306. Its contents include:
a) Product model and name:
b) Product standard number and trademark;
c) Main technical parameters;
d) Manufacturer’s name and address:
e) Factory number and date.
8.2 Packaging
8.2.1 The water distribution pipe inlet and outlet of the wet curtain box should be protected from the entry of debris. 8.2.2 According to the storage and transportation conditions of the wet curtain box, a firm packaging type should be used to ensure that the wet curtain material and the box are not collided or damaged. 8.2.3 The following documents should be included in the packaging box:
a) Product certificate:
b) Product instruction manual, which should comply with the relevant provisions of GB9969.1:c) Packing list;
d) List of accessories, spare parts, and random tools; e) User opinion survey form.
8.3 Transportation and storage
8.3.1 During transportation, the product should not be collided or squeezed. 2 The product should be stored in a ventilated and dry warehouse or canopy to prevent damage from collision and corrosion from corrosive gases. 8.3.2
Mechanical Industry Standard
Wet Curtain Cooling Device
JB/T10294—2001
Published by the Mechanical Science Research Institute
Printed by the Mechanical Science Research Institute
(No. 2, Shouti South Road, Beijing: Postal Code 100044)*
Format 880X12301/16 Printing sheet 3/4
4 Word count 14.000
First edition in September 2001
First printing in September 2001
Print run 1-500
Price 1200 yuan
2001-135
Mechanical Industry Standard Service Network: http/AvwwJB.ac.cn
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.