This standard specifies the characteristics and use of test targets for 16mm flat-bed microfilm cameras. This standard applies to 105mm×mm microfilm cameras. This standard does not apply to COM microfilm cameras and rotary microfilm cameras. GB/T 12356-1990 Microfilming Technology Characteristics and Use of Test Targets for 16mm Flat-bed Microfilm Cameras GB/T12356-1990 Standard download decompression password: www.bzxz.net
This standard specifies the characteristics and use of test targets for 16mm flat-bed microfilm cameras. This standard applies to 105mm×mm microfilm cameras. This standard does not apply to COM microfilm cameras and rotary microfilm cameras.
Some standard content:
National Standard of the People's Republic of China Micrographic Technology Characteristics and Use of Test Target Plates for 16mm Platform Microfilm Recorders Micrographles--Test object charaeter and instruction for 16 mmmicrofilm recorder 1 Subject content and scope of application GB/T 12356-90 This standard specifies the characteristics and use of test targets for 16mm platform microfilm recorders. This standard is also applicable to 1n5mm×148mm microfilm recorders. This standard is not applicable to COM microfilm cameras and rotary microfilm cameras. 2 Reference standards GB6161 Microfilming Technology No. 2 Test Pattern Characteristics and Its Application in Microfilming GB8987 Microfilming Technology Test Standard for Testing Optical Density of Negative Images in Microfilming 3 Test Standard 3.1 Bottom Plate Material The bottom plate of the test standard plate shall be a white matte material with stable dimensions or a lead plate with a black surface, and the thickness shall be less than 2mm. 3.2 Plate Size This standard plate is divided into two types: Plate A is 297mm×210mm, and Plate B is 297mm×420mm. 3.3 Shrinkage Test Ruler The 10mm×100mm shrinkage test ruler at 35mm square to the center of the center test pattern array indicates the measurement unit in millimeters, with a character height of not less than 2mm, and is parallel to the bottom of the test standard plate. 3.4 Test pattern arrangement Five No. 2 test patterns that meet the requirements of GB6161 are located at the center and four corners of the target plate as shown in the figure below. The array center of the No. 2 test pattern located in the center should be at the center of the test target plate, with a deviation error within 2 μm, and the edges of the test pattern parallel to the edges of the test target plate. The array center of the No. 2 test pattern located at the four corners should be on the diagonal of the target plate, 0.35 (d represents the length of the diagonal) from the center of the target plate, and the deviation error should be within 2m; the side of the test pattern is parallel to the diagonal: from the center of the test target plate, the numbers on the test pattern should be read clockwise, State Administration of Technical Supervision 7990-06-11 approved 1991-03-01 practice Note: I1R represents the reduction rate, wwW.bzxz.Net 3.5 Reduction rate math card GB/T12356 As shown in the figure, the black background white letter (equilinear font) card marked with 1:R is placed directly below the center test pattern. 55mm away from the center of the test pattern array, the height is not less than 15mm. 4 Usage 4.1A plate uses half-frame microfilm. 4.2B plate is used for full-frame microfilming. 4.3 When using the entry plate and B plate, the standard plate specified in GB8987 shall be used under the same conditions, and another frame shall be photographed. The determination of resolution shall be carried out in accordance with the method specified in GB 6161. Additional remarks: This standard was proposed by the National Technical Committee for Standardization of Microfilm Technology. This standard was drafted by the Fourth Technical Committee of the National Technical Committee for Standardization of Microfilm Technology. The main drafters of this standard are Zeng Jin and He Shaoxi. Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.