This standard specifies the technical requirements, test methods, inspection rules, quality assurance period, marking, packaging, transportation and storage requirements of SZ series micro DC servo motors. This standard applies to SZ series micro DC servo motors (hereinafter referred to as motors). This series of motors are separately excited DC servo motors with commutators, which can be used as actuators in automatic control systems and can also be used as drive components. This series of motors are divided into two categories according to the operating environment conditions: ordinary type and humid tropical type (indoor). The humid tropical type motor has "TH" added after the ordinary type model. This series of motors is not suitable for environmental conditions with special requirements, such as: explosion-proof, oil-resistant, chemical corrosion-resistant, exposed to the sun, rain, etc. JB/T 1377.1-1999 SZ series micro DC servo motors JB/T1377.1-1999 Standard download decompression password: www.bzxz.net
Some standard content:
The standard of the People's Republic of China for the hydraulic press machinery industry JB/T1377.11999 1999-08-064 2000-01-01 JB/T1377.1±1999 This standard is a revision of JB1377-74 "SZ series micro DC servo motor". The relevant provisions in GB/T7345-1994 and GB/T14819-1993 were cited during the revision. This standard is consistent with the relevant standards and conforms to the provisions of GB/T1.1-1993 in terms of writing format: This standard will replace JB1377-74 from the date of implementation. This standard is proposed and managed by the National Micro Motor Standardization Technical Committee. The drafting units of this standard are: Boyu Motor Factory, Tianjin Safety Motor Co., Ltd., Qinghai Micro Motor Factory, Benxi Micro Motor Factory, Ningbo Kailis Electric Co., Ltd., Fujian Wanda Motor Co., Ltd. The main drafters of this standard are Gao Shaoping and Lu Zhaotong. The motor factory is entrusted with the interpretation of this standard. 1 G2 0P pEe/ JB/T1377.11999 This standard specifies the technical requirements, test methods, inspection rules, quality assurance period, marking, packaging, transportation and storage requirements of SZ series micro DC servo motors. This standard applies to SZ series micro DC servo motors (hereinafter referred to as motors). This series of motors are separately excited DC servo motors with commutators, which can be used as actuators in automatic control systems and can also be used as drive components. This series of motors are divided into two categories according to the use environment conditions: ordinary type and humid tropical type (indoor). The humid tropical type motor has "TH" added after the ordinary type model. This series of motors is not suitable for environmental conditions with special requirements, such as: explosion-proof, oil-resistant, chemical erosion-resistant, exposed to the sun, rain, etc. Cited Standards The provisions contained in the following standards constitute the provisions of this standard through reference in this standard. When the standard is published, the versions shown are valid: All standards will be revised, and the parties using this standard should explore the possibility of using the latest versions of the following standards. GB/T2423.3-1993 Basic environmental test procedures for electric and electronic products Test Ca: Steady-state damp heat test method GB/T2423.4-1993 Basic environmental test procedures for electric and electronic products Test Db: Alternating damp heat test method GB/T2423.16--1990 Basic environmental test procedures for electric and electronic products Test J: Mildew test method GB/T 7345-1994 Basic technical requirements for controlling micromotors GB/T10069.1-1988 Noise determination method for rotating motors and engineering determination method for limit noise GB/T14819-1993 3 Technical requirements 3.1 Environmental conditions for use General technical conditions for electromagnetic DC servo motors 3.1.1 The air pressure shall not be less than 61.7 kPa (4000m). 3.1.2 Ambient temperature: -40~+55℃ 3.1.3 Relative humidity: 90%~95%. 3.1.4 Any installation position. 3.1.5 The humid tropical type motor is also allowed to work under the following conditions: a) Condensation; b) Mold. 3.2 Working system The motor is a continuous working system. 1999-08-06 2000-01-01 3.3 Circuit diagram The circuit diagram is shown in Figure 1. 3.4 Rated data The rated data of the motor shall comply with the provisions of Table 1. Model 36SZ01 36SZ02 36SZ03 36SZ04 36SZ05 36SZ06 36SZ07 36SZ51 36SZ52 36SZ53 36SZ54 36SZ 55 36SZ56 36SZ57 45SZ01 45SZ02 45SZ03 45SZ04 45SZ05 JB/T1377.11999 Figure 1 Circuit diagram Rated data Allowable positive and negative reverse difference 45SZ06 | |tt | 5SZ58 55SZ01 5 5SZ02 | |tt | | 55SZ03 | Sz54 55SZ55 55 SZ56 55SZ57 55Sz58 70SZ01 70SZ02 70SZ03 70SZ04 70SZ05 JB/T1377.11999 Table 1 (continued) Allowable positive and negative rotation difference 70SZ06| | tt | t||90SZ01 90SZ02| | tt | 110SZ52 110 SZ53 110SZ54 130SZ1 130SZ02 130SZ03 130SZ04 Rated data are checked in cold state, JB/T1377.11999 Table 1 (end) The motor output is based on torque, Power is for reference only. is ±12%; 55SZ~130SZ 3 Speed tolerance: 36SZ~45SZ Armature excitation is ±10% Allowable forward and reverse rotation difference 3.5 Structural type 3.5.1 The motor is a closed self-cooling type JB/T1377.11999 3.5.2 The motor can be made into the installation structure type shown in Table 2. The shaft extension can be made into single shaft extension and double shaft extension. For double shaft extension motors, the commutator end shaft extension is not used to transmit rated torque. Table 2 Installation structure type Installation structure type Machine base outer circle installation End cover flange installation Foot installation 3.6 Appearance and installation dimensions Installation structure type code Single shaft extension Double shaft extension The appearance dimensions and installation dimensions of the motor shall comply with the provisions of Figures 2 to 9 and Tables 3 to 7. Note: The dimensions without tolerance in the figures are basic dimensions. h Figure 2 Appearance and installation dimensions Table 3 Appearance and installation dimensions 36SZ01-07 36SZ51~57www.bzxz.net 45SZ01-08 45SZ51~58 Machine frame size 36~130 36~130 90~130 365201-07 36SZ51-57 45SZ51- JB/T1377.11999 Figure 3 Appearance and installation dimensions Table 4 Appearance and installation dimensions Figure 4 Appearance and installation dimensions 55SZ01-08 55SZ51-58 70SZ01~08 7OSZ51-58 908201 -04 90Sz51-64 110SZ01~04 110SZ51-5 JB/T1377.11999 Qiu 5 Appearance and installation dimensions -0: 15 Figure 5 Appearance and installation dimensions Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.