Some standard content:
ICS 39.040.10
Semicolon, Y11
Preparation number: 16403-2005
Light Industry Standard of the People's Republic of China
QB/T1987-2005
Find B/1987—1994
Quartz clocks for public use
Quartz clocks for public usc
Published on 2005-07-26
National Development and Reform Commission of the People's Republic of China Implemented on 2006-01-01
This standard is a revision of QB/T1987-1994 "Quartz clocks for building use". The main changes compared with QB/T1987—1994 are as follows: The name of the standard is changed from "Quartz clocks for public use" to "Quartz clocks for public use": QB/1987—2 005
The reference in the "scope" of Chapter 1 has changed from more than 1.5m to 0.4m: and the maximum height of the maximum indication time is not less than 0mm. Regarding the change of the inspection method, two standards, GB/2828.1 Counting sampling inspection Part 1: Sampling plan for batch inspection according to acceptance quality limit (AQL) inspection and GB/T2829 Periodic inspection efficiency sampling procedures and tables (applicable to the inspection of process stability) have been added to the second normative reference document: the "GB776 Technical conditions for electrical measuring instruments" quoted in the past has been changed to "GB14536.1-1998 Household and similar electric controllers Part 1: General requirements", because the latter's scope of application includes the products covered by this standard and is commonly used in meter testing. .…—Added Chapter 3 "Terms and Definitions" and made new provisions for the minimum output force of the minute hand of each type of clock: re-divided the travel time accuracy level, and evaluated the daily difference of the common solution. - Added the requirements for visibility, workability and synchronization of the external display of multi-faceted clocks, hybrid clocks and mother-child clock structures. Since this standard applies to a wider range of products than the original standard, some public clocks have been mass-produced, and the factory inspection rules used in the H standard are no longer applicable. It is determined that the monthly sampling inspection method must be accepted, and the relevant content of the type inspection is added. This standard was proposed by the China Light Industry Federation. This standard is under the jurisdiction of the National Clock and Watch Standardization Center. The main drafting units of this standard are Polaris Watch Group Co., Ltd. and Xi'an Baoyu Technology Co., Ltd., and the Industrial Clock and Watch Research Institute. The main drafters of this standard are Yu Ke, Bu Dusong, Shang Li, Zhang Xuedong, Liu Xiaoming, Zhao Diming. The previous versions of the standards replaced by this standard are: QB/T19B7-[994.
From the date of implementation of this standard, it replaces the light industry standard QB/T1987-1994 Quartz Clocks for Buildings issued by the China Light Industry Association. 1. Scope
Quartz Clocks for Public Use
QB/T-987-2005
This standard specifies the classification, requirements, test methods, inspection and supervision rules, marking, packaging, selection, storage and installation of quartz clocks for public use (hereinafter referred to as "quartz clocks"). This standard is applicable to digital clocks with a diameter of not less than 0.4m and a time display of not less than 70mm. Quartz clocks can be used in public places. 2 Normative references || TT || The above-listed documents become references to this standard through reference in this standard: For all referenced documents, any subsequent amendments (excluding errors) or revisions shall be marked with the same label. However, if the document is missing, the latest version of these documents shall apply. For all undated references, the latest version shall apply. GR/2828.1-2003 Efficient sampling inspection procedures Part 1: Control Acceptance Quality Limit (AQL); Inspection System Batch Inspection Oil Sample Plan GB/T2B29-2002 Periodic Inspection Count and Table (Test Method for Stability of Dust Rate) 0B14536.1-[998 Household and Similar Purposes Market Control Part 1: General Zero Requirements 3 Terms and Definitions
The following terms and definitions apply to this standard. 3.1
Standard Time
The Beijing Time issued by the National Time Service Center is the standard time. 3.2 || tt||The time display unit of the human clock system.
The time display unit of the human clock system,
4 Divisions
4.1 According to the closed form of the clock face
Open
Closed
A human clock with the display part added outside;
A large clock with the display part exposed outside,
4.2 According to the display mode
Indicator type
Combined type
4.3 Control structure
Single clock
Average clock with hands: A clock that indicates time:
A clock that can display time in numbers:
A large clock that indicates time with both numbers and hands. A large clock with hands only and no other clocks
QB/T19872005
A large clock with equal width and space
4.4 Number of clocks
One clock face and one clock face
5 Requirements
There should be a large clock with three clock faces.
5. 1 Two working voltage
minutes! The nominal "working voltage three 2055 flash should not be used. 5.2 Travel time
Dalian natural running "d average instantaneous H card m should comply with the provisions of the table day and index
flat Fm six sd
5.3 Output torque
5.3.1 Pointer into a large clock minute hand material small output female short table 2. Generation
.u5.-- 05
Table 2 Classification of minute hand rotation diameter and minimum output force furnace!
Opening type
Study luxury into a small mountain power station.m
Supply and demand are determined
Total modification
5.3.2 People have my needle, the output of the two parties negotiate 5.4 Full performance
5.4.1 Electrical strong plate
13. 16 - 50)
Minimum pulling force m
Supply and demand parties determine
People are subject to the frequency of Hz, the electric stop party is 2000V, and the electrical end must be tested for 11n: the whole time should be fast. The case shows the phenomenon 5.4. 2. The insulation resistance
of the device and the non-conductive part of the device shall be 20M25.5. The day and minute hand deviation
is large, and the time box is combined with the six centers, and the minute hand deviation from the "12" time center range shall be -1212\Book III 5.6. Display synchronization
5.6.1 The time display deviation of the pointer before the clock is within 2min.5.6.2 The display deviation of the pointer and the pointer shall be -23 and the display deviation shall be within 1. The display difference of the
number and the mother clock and the child clock shall not be less than +5.6.4
5.7. The visibility
day package is required by both parties: 5.8. The working temperature
of the clock shall not be within the range of the device. If the replacement is required, the use of goods to do the effect of the parties to be agreed 5. 9 Reliability of work
QB/T 1987 -2005
5.9.1 The clock should not stop under the operating conditions, during the accuracy test period, the ticket should be greater than 1m. 5.9.2 The digital work should be correct and simple, without missing, multiple periods, hidden and unreliable display and other phenomena. 5.9.3 The clock should be able to show the following when repaired: 5.10 Appearance
5.10.1 The surface and shell of the clock should be regular and flat: no cover layer is uniform, negative one is changed: the plate is small and white, and there is no obvious mark, trace and stain containing carbon dioxide: the picture and the picture should be clear and elastic, and there should be no broken or damaged, and the new picture should be visible. 5.10.2 The sealing of the large clock should be done by the staff, and the characters and markings should be firmly fixed.
5.11 Windproof
The design of windproof should be effective. 512 The large needle should be carefully agreed upon by both parties. 5.13 Time function
5131 Time telling
For a clock with time telling function, the time telling prescription should be: the deviation of the indication system should not be 1mm, and the time telling should be recognized and known when the time is reached, and the normal work of the system should not be disturbed. 5.13.2 Power Switching
When the power is switched, the original working state should not be affected, and the phenomenon should not occur. The original working state should not be affected. The original working state should not be affected. The original working state should not be affected. The original working state should not be affected. The original working state should not be affected. The original working state should not be affected. The original working state should not be affected. The original working state should not be affected. The original working state should not be affected. The original working state should not be affected. The original working state should not be affected. The original working state should not be affected. The original working state should not be affected. The original working state should not be affected. The original working state should not be affected. The original working state should not be affected. The original working state should not be affected. The original working state should not be affected. The original working state should not be affected. The original working state should not be affected.13.3.2 If the current is too high, the internal clock should be able to continue counting, and the normal display should be displayed after the light is turned on. 5.13.4 If the lighting equipment has a clock that can be used to record the time, the lighting equipment should be able to work normally: 5.13.5 If the remote control function is large, the control function should be able to adjust the control function when the car is not started. 5.13.6 If the automatic time card is used, the large clock should be able to automatically calibrate with the indicated time, and the sub-clock should be able to automatically follow the mother time. 6 Test method 1 The equipment should be in working state before the test. 6. 2 Test environment
In addition to the visual inspection, the test environment is (20-5! ℃, machine temperature is not more than 80% QB/T1987-2005
6.3 Pre-operation time
Before the test, the test is carried out in an environment with a temperature of at least 6,2 hours. 6.4 Instruments
Test instruments and equipment and their standards are shown in Table 3 Table 3 Test equipment
Product equipment
Product equipment
Product equipment
Product equipment
Digital voltage tester
Voltage tester
6.5 Test items
6.5.1 Working voltage
Uncertainty level/maximum, chemical tolerance
±oo sd
±0.5 s/d
not less than 2.5 levels
less than 1-2.5 levels
Set the head stopper to the upper and lower limits of the working pressure range respectively, and make it run for 30 minutes each. Observe the operation during the operation period, and the result should meet the requirements of 5.1. 6. 5. 2 Timing accuracy
Put the head continuously in an environment of (1) and calculate the time difference of >4 minutes according to formula (2). The result meets the requirements of 5.2. Use a meter to calculate the time difference. When testing, first measure the period of the signal 71 and then calculate it according to formula (1).
The time difference is in seconds!
TT x 86 400
The nominal service life of the signal to be tested, the unit is sand (3) The actual measured extension period of the tested signal: the unit is (). In this way, the instantaneous components of 1, 2, and 3 are measured respectively, and the formula (2) is calculated. The result should meet the requirements of 3.2: m+m
average time, single second
is the actual time difference of the first [d, the unit is seconds per person (sd): the actual time difference of 2d, the unit is seconds per day (5/d); the actual time difference of the first meal is
, 6.5.3 Output torque
Adjust the minute hand to "3" and "1" values respectively, and start the operation at least once when the minute hand is at 3/4 of the effective rotation diameter. Measure the output torque within one minute. The result shall meet the requirements of the regulations. 6.5.4 Electrical strength
QB/T1987—2005
The electrical strength test of the large clock system shall be carried out in accordance with (IB[4536.1-1998). The result shall meet the requirements of 5.4.1. t.5.5 The control part of the large clock shall be tested according to GB14536.1-199R. The result shall meet the requirements of 5.4.2. 6.5.6 Coordination difference of hour and minute hands
For the adjustable type clock, respectively, check the deviation of the needle position from the center of "3", "6", "9", and "12", and the result shall meet the requirements of 5.3: 6.5.7 Display synchronization
For the hybrid type clock, check the small deviation of the pointer of the digital clock: For the structured clock, check the pointer deviation of the clock: For the table type clock, check the pointer deviation between the standard time and the standard time: The result shall meet the requirements of 5.6. 65. Working temperature
The clock shall be placed in a temperature range of (50°C + 2°C) for 2 hours, then tested in an environment with a temperature range of (-0°C + 2°C) for 2 hours. After burning, it shall be tested in an environment with a temperature range of (-0°C + 2°C) for 2 hours. The test result shall meet the requirements of 5.8.
6.5.9 Working reliability
During the pre-operation period, observe the working characteristics of the clock. During the test, check the actual cumulative error of the average instantaneous error: if the clock can rotate in a large number of ways, the result shall meet the requirements of 5.9. 6.5.10 Appearance
Under natural light, at a distance of m from the person being tested, with normal vision, the signal shall meet the requirements of 5.0. 6.5.11 Time signal || tt||The external clock with a marking frequency represents a time point, check the functions and control points, and the results shall meet the requirements of 5.13.1. 6.5.12 Power supply switching
at a rate of 5, 1 time: turn on or off the clock AC power at a relatively high rate: observe the clock's working state, and the results shall meet the requirements of 5.13.2.
6.5.13 Power-off retention or memory
Cut off the power supply of the clock, pointer-type clock, digital clock, and use the power supply to work 12: after the power is on: connect the AC source and observe the working state of the clock, and the results shall meet the requirements of 5.13.3. 6.5.14 Lighting
will automatically turn the clock on and off at a rate of 1.1:1 to read the working time, check the lighting, and the results shall meet the requirements of 5. [7.4 requirements, 6.5.15 remote control
After the large clock is completely reversed, the remote control device can be used to adjust the various remote control kinetic energy of the clock without any obstruction. The results are as follows: 5.13.5 requirements
6.5.16 automatic time adjustment
The time between the approved time and the world clock is determined by the automatic change. If there is a difference between the actual time and the actual time, the automatic change will be checked three times respectively. The results should be as follows: 5.13.6 requirements. Inspection rules wwW.bzxz.Net
7.1 Acceptance inspection
7.1.1 The human clock is not produced in batches. The acceptance inspection rate is degraded and the inspection items are based on Table 4. It is also agreed by the supply and demand parties. When conducting the inspection, if any item is unqualified, the product is unqualified. 7.1.2 When the human clock is not produced in batches, the acceptance inspection rate is degraded and the inspection items are degraded. The inspection items can be based on Table 4. It is also agreed by the supply and demand parties. When conducting the inspection, if any item is unqualified, the product is unqualified. When the production is continued, the inspection period is carried out according to GB/T2828.1-2003, and the discrimination level TTT and one-time sampling method are adopted. The sample method and the acceptance quality limit are determined by the supply and demand parties. 7.1.3 The inspection items can be determined according to GB/T1987-2005 or agreed upon by the supply and demand parties. 7.1.4 The qualified judgment and the treatment of the approved samples after inspection shall be carried out according to GB/T2828.1-2003. 7.2 Type inspection 7.2.1 Inspection items Type inspection is carried out according to GB/T2829-2002, and the discrimination level IT is adopted, and the one-time sampling method is implemented. The inspection items are shown in Table 4, and the sample method and the unqualified quality level RQL shall be agreed upon by the supply and demand parties. Table 4 Inspection items
Operation reliability
Timing accuracy
Torque
Electrical strength
Insulation resistance
Inspection items
Digital hand coordination difference
Display asynchronism
Working disk speed
Power switching
Internal holding
Automatic calibration
Type inspection
Acceptance inspection
Note 1: "." indicates mandatory inspection items, "" indicates calibration items agreed upon by the supply and demand parties, "\" indicates that the function can be completed in the field and is not required as a type test question. When the product structure does not have industrial function requirements, no prior inspection is required. 7.2.2 Qualification determination
Qualification determination and disposal of tested batches and samples The version of GB/T 2829-2002 stipulates that the implementation period is generally every two years. - Modification: - When the above situations occur, type inspection should also be carried out: 1) When a new product is produced for trial production and type appraisal; 2) When the product design, structure, process, and materials are changed, which affects the product's long-term performance; 3) When the national quality supervision and inspection agency issues an inspection requirement. 6
Date marking, packaging, transportation, storage, installation 8.1 Marking, labeling, instruction manual
Q/T19872005
The product should be marked with the manufacturer's name, front label, product model and date of production, and attached with product certificate and instruction manual. The instruction manual [5] should have the following contents:
Product name, production station specification:
6Manufacturer name and address
) Standard abbreviation, grade:
d) Production period:
「】Instructions for use and maintenance:
g) Warranty period:
h) Other matters that the manufacturer should explain beside the source of the time and calibration of the automatic time control clock.
B6.2 Packaging and transportation
Large clocks are not packed. During transportation, pay attention to the following matters. a) The packaging box of the large aluminum clock should be sturdy and durable, with protective lining, and the signs of "handle with care" and "test carefully" should be on the outside. b) During transportation, it should be handled with care to avoid impact and strong vibration. Special requirements will be determined by the supplier and the supplier through consultation:) For open clocks, the packaging of the cylinder core, clock face, dial, clock face and their conditions shall be unpacked by the installation personnel designated by the manufacturer. 8.3 Storage
The control part should be in a ventilated, dry and non-ionizing gas environment; the storage temperature should be between 10--55, and the relative humidity should be below 0%.
8.4 Installation
The requirements for the installation of the clock shall be determined by the supplier. 7