This standard specifies the parameters and accuracy of vertical single-axis tenon and mortise machines. This standard applies to vertical single-axis tenon and mortise machines (hereinafter referred to as machine tools). QB/T 1625-1992 Vertical single-axis tenon and mortise machine parameters and accuracy QB/T1625-1992 Standard download decompression password: www.bzxz.net
Some standard content:
Light Industry Industry Standard of the People's Republic of China Vertical Single-Axis Slotting Machine Parameters and Accuracy Subject Content and Scope of Application This standard specifies the parameters and accuracy of vertical single-axis slotting machines. This standard is applicable to vertical single-axis slotting machines (hereinafter referred to as machine tools). 2 Reference Standards JB/T 4171 General Rules for Accuracy Inspection of Woodworking Machine Tools 3 Main Parameters of Machine Tools 3.1 See Figure 1 for a simplified diagram of the machine tool. Workbench Note: The machine tool is not limited to its body structure. Approved by the Ministry of Light Industry of the People's Republic of China in 1992-111016 Manually Landed by the InstitutebZxz.net QB/T1625--1992 Implementation in 1993-07-01 The main parameters are shown in Table 1. Main parameter name Maximum slot width Note: The values in brackets should not be used as much as possible. 4 Machine tool accuracy 4.1 Brief description QB/T1625—1992 4.1.1 The order of accuracy inspections listed in this standard does not represent the actual inspection order. In order to facilitate the disassembly and inspection of the machine tool, the inspection can be carried out in any order. 4.1.2 When the actual measured length is different from the length specified in this standard, the tolerance shall be calculated according to the measurable length in accordance with the provisions of Article 2.2.1 of JB/T4171, and the minimum calculated value is 0.01 mm. 4.1.3 Refer to Article 3.1 of JB/T4171 to adjust the installation level of the machine tool, place the level in the middle of the worktable, and its longitudinal and transverse readings shall not exceed 0.10/1000. 4.2 Geometric accuracy See Table 2 for geometric accuracy. Inspection items Flatness of worktable a) Longitudinal straightness b) Horizontal straightness c) Diagonal straight line Radial circle of spindle Straight line of guide plate surface a) and c): A≤630 B≤200 Industry bath room Inspection tools Indicator Inspection method Refer to IB/T 4171 4.2.1.2.2.2 4.2.1.2、2.2 QB/T1625-1992 Continued Table 2 Inspection items Verticality of guide plate to worktable Planeity of left-right movement of worktable and guide plate Verticality of front-back movement of worktable and guide plate Verticality of vertical movement of spindle and guide plate Vertical movement of spindle, Vertical to the work surface The left and right movement of the work table and the plane of its surface It is not allowed to tilt outward 100 length 100 length 300 length Consumer industry stealing market fee basement Inspection tools Indicator Indicator Indicator Indicator Equal height pads Indicator Inspection method Refer to JB/T 4171 4.7.1.2.2.2 4. 4. 2. 2. 2. 1 4.7.2.2.2. 2. 1 4. 4. 2. 2. 2. 2. 1 4.7.2.2.2. 1 4.4.2.2.2.1 4.3Working accuracy See Table 3 for working accuracy. QB/T 1625-1992 Continued Table 2 Inspection items The parallelism of the forward and backward movement of the worktable and its surface The verticality of the lifting and lowering movement of the worktable The parallelism between the center line of the spindle and the Square chisel mounting hole Inspection items The average width of the groove 100 length 100 length Point a: Axis b: Inspection tools Indicator Indicator Inspection rod Inspection tools Inspection method Refer to JB/T4171 4. 4. 2. 2. 2. 2. 1 4. 7. 2. 2. 2. 2. 1 Install the inspection rod on the square chisel mounting hole, touch it with the probe of the indicator fixed on the main shaft, rotate the main shaft by hand, and the maximum difference between the readings of the rotating middle finger and the indicator is the measured value. Inspection method Measure the width of the sample groove on the position shown in the figure with a caliper. The maximum difference is the average error value of the sample width. Note: For hard miscellaneous wood with a moisture content not exceeding 15%, the straightness of the reference surface of the blank material with a size of 600mm×70mm×50mm shall not exceed 0.20 over a length of 1000mm. The test piece is processed to have a through hole with a cross section of 12mm×100mm~25mm×100mm. 19 Approval area Approval of the following Additional instructions: This standard is proposed by the Technical Equipment Department of the Ministry of Light Industry QB/T1625-1992 This standard is under the jurisdiction of the National Furniture Machinery Standardization Center. This standard was drafted by Shenyang Woodworking Machinery Manufacturing Plant and the National Furniture Machinery Technical Service Center. The main drafters of this standard are Fu Yufu and Ding Yuanchun. 20 Standard search network wwm.bzs050.20m China Class Standard Industry Information Science and Technology Division Fee Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.