Standard Classification Number:Electrical Engineering>>Rotary Motors>>K22 Asynchronous Motors
associated standards
Procurement status:neq IEC 34-1, IEC 72
Publication information
publishing house:Mechanical Industry Press
Publication date:1993-01-01
other information
drafter:Hu Chunlei, Yao Zufang, Huang Yaohui, Hong Yuping
Drafting unit:Shanghai Electric Science Research Institute, Shanghai Wuyi Motor Factory, Jiaxing Motor Factory were responsible for drafting. Xinxiang Motor General, Heilongjiang Motor General,
Focal point unit:Shanghai Electric Science Research Institute, Ministry of Machinery and Electronics Industry
Proposing unit:Shanghai Electric Science Research Institute, Ministry of Machinery and Electronics Industry
Publishing department:Ministry of Machinery Industry of the People's Republic of China
This standard specifies the type, basic parameters and dimensions, technical requirements, inspection rules, test methods, and marking and packaging requirements of YLJ series torque two-phase asynchronous motors (hereinafter referred to as motors). This standard applies to winding motors (IP44 frame size 100-1601IP21 frame size 63.180). All motors with other structural types and special performance requirements belonging to this series of motors can also refer to it. JB/T 6297-1992 Technical conditions for YLJ series torque three-phase asynchronous motors JB/T6297-1992 Standard download decompression password: www.bzxz.net
Some standard content:
Mechanical Industry Standard of the People's Republic of China Technical Conditions for YLJ Series Torque Three-phase Asynchronous Motors Subject Content and Scope of Application JB/T 6297-92 This standard specifies the types, basic parameters and dimensions, technical requirements, inspection rules, test methods, and marking and packaging requirements of YLJ series torque three-phase asynchronous motors (hereinafter referred to as motors). This standard applies to YLJ series torque three-phase asynchronous motors for winding (IP44 frame size 100~160, IP21 frame size 63~180), and all motors derived from this series of motors with other structural types and special performance requirements can also refer to it for implementation. 2 Reference standards Basic technical requirements for rotating electrical machines GB4942.1 Motor housing protection classification GB1993 Motor cooling method Motor structure installation type and code GB4772.1 Motor dimensions and tolerances Motors with frame size 36 to 400 and flange number FF55-FF1080 or FT55 to FT1080 GB12665 GB10069 GB10068 GB1032 JB/Z294 JB/ Z346 Wet heat test requirements for motors used under general environmental conditionsDetermination method and limit of noise of rotating motors Determination method and limit of vibration of rotating motors Test method of three-phase asynchronous motors Packaging, storage and transportation index marking Test method for turn-to-turn insulation of loose-embedded windings of AC low-voltage motorsTest limit of turn-to-turn insulation of loose-embedded windings of AC low-voltage motors3. Types, basic parameters and dimensions 3:1The enclosure protection grade of the motor is IP44 (frame size 100~160) and IP21 (frame size 63~180) (see GB4942.1). 3.2 The cooling method of the motor is (IC0141 (IP44, frame size 100~160), IC00 (IP21, frame size 63~90) and IC06 (IP21, frame size 100180) (see GB1993). 3.3 The structure and installation type of the motor are IMB3, IMB5 and IMB14 (see GB:997). 3.4 The motor rating is based on the non-periodic working rating of the S9 working system with continuous changes in load and speed from no-load to stall. 3.5 The rated rate of the motor is 50Hz and the rated voltage is 380V. 3.6 Rated stall torque and rated stall current. The rated stall torque and rated stall current are the rated Constant voltage. The stall torque and stall current measured at the rated frequency according to the specified allowable stall time limit. The corresponding relationship between the motor frame number, synchronous speed and rated stall torque shall comply with the provisions of Table 1 and Table 2. The motor shall be manufactured according to the following rated stall torques: 0.5, 1.0, 1.6, 2.0, 3.0, 4.0, 5.0, 6.0, 10, 16, 25, 40, 60, 80, 100, 125, 160, 200 Nm3.7 The allowable stall time of the motor shall not be less than the provisions of Table 1 and Table 2 Ministry of Machinery and Electronics Industry 1992--06--26 Approved 1993-01-01 Implementation Frame number JB/T 6297-92 Table 1 (Applicable to protection grade IP44) Synchronous speed Rated stall torque (Applicable to protection grade IP21) Synchronous speed Rated stall torque Allowable stall Allowable stall 3.8 Motor dimensions and tolerances Motor installation dimensions and tolerances The difference shall comply with the provisions of Table 3 to Table 8, and the overall dimensions shall not be greater than those specified in Table 3 to Table 8. 3.8.1 1616791/8 Lishuigong table family wax 26167918 Lu number 920 year Shuiding ticket family ·Yaosheng 26629/ Lujundiao JB/T 6297--92 The dimensions and tolerances of the motor shaft extension key shall comply with the provisions of Table 9. Table 9 The radial runout tolerance at half the shaft extension length shall comply with the provisions of Table 10. Table 10 Shaft extension diameter >10~18 >18~30 >30~50Www.bzxZ.net Western runout tolerance The radial runout tolerance of the flange stop to the motor axis and the end face runout tolerance of the flange mating surface to the motor axis shall comply with the provisions of Table 113.8.4 . >95~230 >230~300 The flatness tolerance of the motor foot support shall comply with the provisions of Table 12. 3.8.5 AB size >100~160 >160~250 >250~400 Runout tolerance Surface tolerance Rated stall 1500z/min JB/T6297—92 Continued Table 15 (Applicable to protection grade IP21) Maximum stall current 1000r/min 750/min Rated stall 1500r/min Maximum stall current 1000r/min 750r/min 4.5. Under rated voltage and rated frequency, the maximum change rate of torque of the measured mechanical characteristic curve within the range of 1/4 to 3/4 synchronous speed shall not exceed 10%. Maximum change rate of torque. Calculate as follows: d ×100% ×100% Wherein; T, corresponds to the torque value at speed n on the linear mechanical characteristic curve formed by connecting the two-point torque values at 1/4 and 3/4 synchronous speed on the measured mechanical characteristic curve, N·m; T- corresponds to the torque value at speed n' on the measured mechanical characteristic curve, N·m; - is the speed corresponding to the maximum torque deviation between the measured mechanical characteristic curve and the linear mechanical characteristic, r/min. 4.6, the tolerance of the rated stall torque of the motor is -15% and +25% of the guaranteed value. 4.7 The A-weighted sound power level value measured when the motor is no-load should not be greater than the provisions of Table 16 and Table 17. The tolerance of the noise limit is +3dB (A). (Applicable to protection grade IP44) Rated stall torque 1500r/min Sound power level 1000r/min 750r/min Cooling method IC0141 -JB/T6297--92 Parallelism tolerance of motor axis to bottom spleen support surface shall not exceed 0.40mm. The symmetry tolerance of keyway on motor shaft extension shall comply with the provisions of Table 13. Table 13 Technical requirements The motor shall comply with the requirements of this standard and be manufactured in accordance with the drawings and technical documents approved by the prescribed procedures. 4.1 4.2 The altitude, ambient air temperature and relative humidity conditions of the motor operation site shall comply with the following provisions. 4.2.1 The altitude shall not exceed 1000m. 4.2.2 The maximum ambient air temperature varies with the seasons, but does not exceed 40°C. mm Note: If the motor is specified to be used under the conditions where the sea cover exceeds 1000m or the ambient air temperature is higher or lower than 40°C, it should comply with the provisions of GB755. The minimum ambient air temperature is -15°C. The average maximum relative humidity in the wettest month is 90%, and the average minimum temperature in the month is not higher than 25°C. 4.2.4 4.3 The maximum locked-rotor current value of the motor at rated voltage, rated frequency and actual cold state shall not exceed the provisions of Table 14 and Table 15. The ratio k of the torque at 1/4 and 3/4 synchronous speed on the actual measured mechanical characteristic curve of the motor at rated voltage and rated frequency is called the characteristic coefficient. For motors with frame sizes of 132 and below, k ≥ 2.0, and for motors with frame sizes of 160 to 180, k ≥ 1.6. Rated stall torque Rated stall 1500 x/mic vertical (applicable to protection grade P44) Maximum stall current 1500r/min 1000t/min (applicable to protection grade IP21) Maximum stall current 1000 r/mig 750 x/min Rated stall 1500 r/main 750z/min Maximum stall current 1000/min 750r/min Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.