title>GB 19079.10-2005 Opening conditions and technical requirements for sports venues Part 10: Diving venues - GB 19079.10-2005 - Chinese standardNet - bzxz.net
Home > GB > GB 19079.10-2005 Opening conditions and technical requirements for sports venues Part 10: Diving venues
GB 19079.10-2005 Opening conditions and technical requirements for sports venues Part 10: Diving venues

Basic Information

Standard ID: GB 19079.10-2005

Standard Name: Opening conditions and technical requirements for sports venues Part 10: Diving venues

Chinese Name: 体育场所开放条件与技术要求 第l0部分:潜水场所

Standard category:National Standard (GB)

state:in force

Date of Release2005-01-24

Date of Implementation:2005-06-01

standard classification number

Standard ICS number:Household and commercial equipment, recreation, sports >> 97.220 Sports equipment and facilities

Standard Classification Number:Light Industry, Culture and Living Goods>>Culture, Education, Sports and Entertainment Goods>>Y55 Sports Facilities and Equipment

associated standards

Publication information

publishing house:China Standards Press

ISBN:155066.1-22408

Plan number:20032356-Q-451

Publication date:2005-06-01

other information

Release date:2005-01-24

drafter:Yu Qian, Su Ke, Shi Chunjian, Li Zhi, Nie Wei, Li Mingqin, Chen Xueling

Drafting unit:Peking University, National Sports General Administration Aquatic Sports Management Center

Focal point unit:Sports Economics Department of the State Sports General Administration

Proposing unit:State Sports General Administration

Publishing department:General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China Standardization Administration of China

competent authority:State Sports General Administration

Introduction to standards:

This part of GB 19079 stipulates the basic conditions and basic technical requirements for the opening of diving sites. This part applies to all types of artificial diving sites and fixed natural diving sites open to the public. GB 19079.10-2005 Opening conditions and technical requirements for sports venues Part 10: Diving sites GB19079.10-2005 Standard download decompression password: www.bzxz.net

Some standard content:

ICS_97.220
National Standard of the People's Republic of China
GB 19079, 10—2005
Operation conditions and technical requirements for gymnasium and playgroundPart 10: Scuba diving place
200501-24Promulgated
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of ChinaStandardization Administration of the People's Republic of China
2005-06-01Implementation
GF19079 "Operation conditions and technical requirements for gymnasium and playground" is divided into the following parts:...Part · Swimming places·
-Part 2· Card" 4 places
Part 3: Bungee jumping places:
.-Part 4: Rock climbing places:
.Part . Roller skating places·||t t||Part 6: Skiing places;
Part 7: Skating places;
-Part 8: Shooting places;
·Part 9: Archery places;
--Part 10: Diving places:
-Part 17: Rafting places;
Part 2: Paragliding places;
--Part 13: Hot air balloon places:
Part 14: Powered paragliding places:
This part is Part 10 of GB19079, and all the contents of this part are mandatory. This part is under the jurisdiction and interpretation of the Sports Economics Department of the State Sports General Administration. Drafting units of this part: Peking University, Water Sports Management Center of the State Sports General Administration. Drafting persons of this part: Yu Hao, Su Ke, Shi Chunjian, Li Zhi, Nie Wei, Li Mingqin, Chen Xueling. GB 19079.10—2005
1 Scope
Opening conditions and technical requirements for sports venues
Part 10: Diving venues
GB 19079. 10-2005
This part of GB19079 specifies the basic conditions and basic technical requirements that diving venues should have. This part applies to all types of artificial diving venues and fixed natural diving venues open to the public. 2 Normative references
The clauses in the following documents become the clauses of this standard through reference in 19979: For any dated referenced document, all subsequent amendments (including errata) or revisions are not applicable to this standard. However, the parties to the agreement based on this standard are encouraged to study whether the latest versions of these documents can be used. For any undated referenced document, the latest version shall be used for this standard. GB3C97 Seawater quality standard
GB6566 Radionuclides limit standard for building materials GB9667 Sanitary standard for swimming places
(3139668 Health and safety standard for gymnasiums
GB18435 Breathing gas standard for divers
GB/T17093 Sanitary standard for total number of bacteria in indoor air GB/T10001.1 Graphic symbols for public information for signs Part 1: General symbols 3 Terms and definitions
The following terms and definitions apply to this part of GB19079. 3.1
Diving places scuba diving Divingplace
A place where people can carry out diving training, competition, fitness and leisure activities. It includes: a human diving place and a fixed natural diving place.
Diving equipment
refers to the equipment used by people when they are diving. It includes: diving mask, breathing tube, breathing regulator, underwater lighting, air cylinder, treading suit, diving boots, toe drill, buoyancy regulator, etc. 3.3
Diving instructor refers to the person who teaches diving sports theory and skills. 3.4
Experience diving Diving refers to diving activities performed by people without diving qualifications under the accompaniment and guidance of diving instructors. 4 Qualifications of practitioners
4.1 Water technical instructors, water quality inspectors, security personnel, etc. must hold a national professional qualification certificate before they can take up their posts. 4.2 Water technical instructors must undergo a physical examination every year and obtain a physical health certificate before they can take up their posts. comGB 19079. 10—2005
5 Site, facilities and equipment conditions
5.1 Artificial diving site
5.1.1 The diving pool should meet the following requirements: - The pool wall and bottom should be light-colored
The construction quality should meet the requirements of the national building code, and the construction materials should meet the requirements of (H6566!). - The static friction coefficient of the ground around the diving pool should not be less than 0.5. 5.1.2 Sedimentation and suction equipment or automatic water circulation filtration, disinfection and suction equipment should obtain product inspection certificates issued by professional and technical organizations that meet the statutory conditions.
5.1.3 Diving pool The horizontal illumination before the water is not less than 801x5.1.4: There should be a forced-pass condensation disinfection pool between the locker room and the diving pool. 5.2 Fixed natural diving sites
5.2.1 There are clear and regular dangerous area signs. 5.2.2 There is a command (lookout) ship that can overlook the entire port diving area. 5.3 Diving equipment
5.3.1 Diving equipment should be complete and in good condition. 5.3.2 Diving equipment should obtain a product inspection certificate issued by a professional and technical organization that meets the legal conditions. 5.3.3 Gas cylinders should be inspected and qualified by a professional and technical organization that meets the legal conditions every two years before they can be used. 5.4 Auxiliary facilities
There are men's and women's dressing rooms, equipped with facilities for storing clothes, 5.4.1
5.4.2 There are men's and women's shower rooms, the static friction coefficient of the floor surface is not less than 0.5, 5.4.3 There are men's and women's toilets
5.4.4 There are broadcasting and communication equipment.
5.4.5 There is a ventilated and dry storage space for diving equipment. 5.4.6 Indoor diving sites have emergency evacuation routes 5.4.7 Indoor diving sites have ventilation facilities, and the indoor air meets the requirements of GB/T1709. 5.4.8 Public signs meet the requirements of GB/T10001.1 6
Air, sanitation, and environmental management requirements
6.1 Diving sites provide reports on temperature and water overflow 6.2 Fixed natural diving sites provide reports on local weather and tidal changes 6.3 Water quality and sanitation in flooded sites meet the requirements of GH9667, GH9668, and G133097 6.4 The air quality in diving sites meets the requirements of GB1667, GB181668, and GB/T17093 6.5 The environmental sanitation of diving sites meets the requirements of GB9667, G139668 7 Safety Assurance
7.1 Facilities
7.1.1 Fixed natural diving sites should have several lifeboats. 7.1.2 The diving site should be located in a designated hospital with reduced cabin facilities. 7.1.3 Lifebuoys, lifeboats, and life preservers should be provided at the diving site. 7.1.4 First aid medicines and equipment should be placed in a visible and accessible location. 7.2 Safety System
7.2.1 There should be "Instructions for Divers" and safety notices at the wake-up location. 2 Drowning emergency rescue operation procedures and drowning accident handling system should be hung in a conspicuous location. 7.2.2
There should be a dedicated person responsible for the maintenance, repair and inflation of air compressors. Divers' breathing apparatus should comply with the requirements of industry B18435. 7.2.4
There should be obvious signs for all types of personnel on duty.www.bzxz.net
GR 19079.10--2005
Only diving technical instructors with four-star diver qualification certificates can take students to experience diving. The ratio of diving technical instructors to students,
There are health security protection, safety rescue, health inspection, equipment maintenance system and personnel service post nobility system, 7. 2. 7