This standard specifies the types and dimensions of bayonet lamp holders. This standard applies to the types and dimensions of bayonet lamp holders for electric light sources. GB 1407-1996 Types and dimensions of bayonet lamp holders GB1407-1996 Standard download decompression password: www.bzxz.net
Some standard content:
GB1407-1996 This standard is equivalent to the negative contents of 7004-8-1, 7004-9-1, 7004-10-6, 7004-10A-2, 7004-11A-8, 7004-11B7, 7004-11C-2, 7004-11D-1, 7004-12-7, 7004-13-4, 7004-14-7, 7004-15-2, 7004-17-3, 7004-18-1, 7004-19-1 of IEC61-1Q "Lamp holders, lampholders and test standards for their safety and interchangeability - Part 1: Lamp holders" (revised in November 1994). The B9s/14, B129/12, B12s/13, B22s/29X26 and B22d/30×30 in the original GB1407-78 "Types and Dimensions of Plug-in Lamp Holders" are not the specifications in IFC61-1Q, so they are cancelled in this standard. After the implementation of this standard, the original GB1407-78 "Types and Dimensions of Plug-in Lamp Holders" will be abolished. This standard is proposed by China Light Industry General Association. This standard is under the jurisdiction of the National Electric Light Source Standardization Center. This standard was drafted by Beijing Electric Light Source Research Institute. The main drafters of this standard are Wang Yinquan and Jie Tianrui. ..comGB 1407- 1996 EC Preface 1. The formal resolutions or agreements of the International Technical Committee on technical issues are drafted by the technical committees with representatives of the national committees that have special interests in the issue. It expresses the international consensus on the issues studied as much as possible. 2. These resolutions or agreements take the form of recommended standards for international use and, in this sense, are accepted by the national committees. 3. In order to promote international unification, the International Electrotechnical Commission hopes that countries that do not have national standards yet will adopt the recommended standards of the International Electrotechnical Commission as the basis for formulating their national standards when national conditions permit. 4. The International Electrotechnical Commission requires national committees to strive to coordinate their national standards with the recommended standards cabinet when national conditions permit, so as to promote international consistency on these issues. ..com1 Standard National Standard of the People's Republic of China Types and dinientions of hayunet amp caps Types and dinientions of hayunet amp caps This standard specifies the types and dimensions of bayonet lamp caps. This standard applies to the types and dimensions of bayonet lamp caps for electric light sources. 2 Referenced standards GB 14071996 eqyIEc61-1Q:1994 Replacement GB 143778 The provisions contained in the following standards constitute the provisions of this standard through reference in this standard. When this standard is published, the versions shown are valid. All standards will be revised, and parties using this standard should explore the possibility of using the latest version of the following standards. QB2218-1996 Nomenclature of lamp holders and lampholders 3 Types and dimensions 3.1 The type of lamp holder shall comply with the provisions of QB2218-1996. 3.2 The type and dimensions of bottom-end lamp holders shall comply with the provisions of Figures 1 to 15 and Tables 1 to 15 BA75 BA9s/13. BA9s/14 BAZ15d BA15s-3(100°/135\) RAX15d BAU159 PA21-3(120\) B22d(90/136°) See Figure 1 and Table] See Figure 2 and Table 2 See Figure 3 and Table 3 See Figure 4 and Table 4 See Figure 5 and Table 5 See Figure 6 and Table 6 See Figure 7 and Table 7 See Figure 8 and Table 8 See Figure 9 and Table 9 See Figure 10 and Table 10 See Figure 11 and Table 11 See Figure 12 and Table 12 See Figure 13 and Table 13 See Figure 14 and Table 14 See Figure 15 and Table 15 Approved by the State Administration of Technical Supervision on September 5, 1996, implemented on September 1, 1997 Excluding solder Including smelting GB 14071996 The attached figure only shows the inspection scale, the unit is mmBA7s/11 11. 5±0.3 The angle between the tip and the lamp holder It can be a right angle and the maximum can be 105 The lamp holder can be ridiculed, and its diameter is not allowed to exceed the maximum value of the lamp holder without a flared mouth, 5 t, Table 1 Dimensions represent symbols Minimum value Unassembled lamp cap Nominal a0 Maximum value Lamp cap on finished lamp Minimum value Nominal 30° 1) Both the maximum and minimum values of A are measured within the minimum range shown in N. Below the range shown in N, only the maximum value of A is limited. Maximum value BA9s/13 GB1407www.bzxz.net The attached figure only shows the inspection dimensions, the unit is mm13.1±0.2 Excluding solder Including solder The lamp cap can be a bell mouth, and its diameter is not allowed to exceed the maximum 0.5 mm of the lamp cap without a suction port. Table 2 Dimensions Symbols Minimum Unassembled lamp cap Maximum D, 241 BA9s/14 14.0±0.25 Lamp cap on finished lamp Minimum Maximum I) The maximum value of A is measured within the small range shown by N. Below N, only the maximum value of A is limited. 9.25 GB1407-1996 As required Recommended height: 14mm Including solder Excluding welding The lamp cap may be flared, and its diameter is not allowed to exceed the maximum value of the lamp cap without flare by 0.5mm. Table 3 Dimension representative symbol Minimum value Unassembled lamp holder Maximum value Nominal 150° Lamp holder on product lamp Minimum value Nominal 150° 1) The maximum and minimum values of A should be measured within the minimum range shown in N. Below the range shown in N, only the maximum value of A is limited. Maximum value GB 1407—1996 Determined as needed Recommended width: 14 mm Excluding solder Including solder The lamp cap may be flared or larger, and its diameter is not allowed to exceed the maximum value of the lamp cap without flare by 0.5 mm. Table 4 Dimensional symbols Large diameter Unassembled lamp cap Maximum value Number 120° Lamp cap on assembled lamp Minimum value Nominal 120° Maximum value 1) Both the maximum and minimum values of A shall be measured within the range shown in N. Below the range shown in N, only A is limited. Maximum value. Excluding solder Including solder GB1407-1996 According to the micro requirements Recommended height, 1.5mm±0.25tm, 15.0mm:t0.25ma, 21.0mm-0.25mm lamp holder can be thiophene port, H diameter is not allowed to exceed the maximum value of the lamp holder without thiophene 1. 00mm, 3415d Sleeve-shaped contact Face-shaped tip All other dimensions are the same as BA75d Dimension symbol Minimum value GB1407-:1996 Unassembled lamp holder Maximum value Near false 9 Nominal 90° Lamp holder on finished lamp Minimum value Nominal 90″ 1) The maximum and minimum values of A should be measured within the range shown in N. Within the range shown in N, 5 limits the maximum value of A. 2) For the lamp holder on the finished lamp with bone-shaped contact, the height difference between the two contacts with solder shall not exceed F0.nun, maximum value excluding solder including solder reference pin GB 1407-1996 as required recommended value: 18mm.13mm.21mm the head can be a bell mouth, and its diameter is not allowed to exceed the maximum value of the lamp holder without bell mouth by 1.00mm: BAY15d planted round lamp round lamp HAYT5s all other relevant dimensions are alternate with BAYI5d lamp holder symbol in the scale minimum GB1407-1996 unassembled lamp holder maximum value 15, 25 Reverse 9 Nominal Sr Lamp holder on finished lamp Minimum value 1) The maximum and minimum values of A shall be measured within the minimum range shown in N. Within the range shown in N, only the maximum value of A shall be limited. 2) For the lamp holder on the finished lamp with strip contacts, the difference in height between the two contacts with materials shall not exceed 0.5mml. Maximum value Including solder Reference pins GB1407-1996 BAZI5d According to requirements Required height: 19.cmm, 3.25mm, 21.0mm±0.25mal. The lamp holder can be a flare. Its diameter is not allowed to exceed the maximum value of the lamp holder without a flare 1.c0mm, round contact Contact Does not include solder Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.