title>GB 1407-1996 Types and dimensions of bayonet lamp holders - GB 1407-1996 - Chinese standardNet - bzxz.net
Home > GB > GB 1407-1996 Types and dimensions of bayonet lamp holders
GB 1407-1996 Types and dimensions of bayonet lamp holders

Basic Information

Standard ID: GB 1407-1996

Standard Name: Types and dimensions of bayonet lamp holders

Chinese Name: 卡口式灯头的型式和尺寸

Standard category:National Standard (GB)

state:Abolished

Date of Release1996-09-05

Date of Implementation:1997-09-01

Date of Expiration:2008-12-01

standard classification number

Standard ICS number:Electrical engineering>>Electric lamps and related devices>>29.140.10 Lamp caps and lamp holders

Standard Classification Number:Electrical Engineering>>Electrical Lighting>>K74 Lighting Accessories

associated standards

alternative situation:Replaced GB 1407-1978; replaced by GB/T 1406.5-2008

Procurement status:eqv IEC 61-1Q:1994

Publication information

publishing house:China Standards Press

ISBN:155066.1-13751

Publication date:2004-04-01

other information

Release date:1978-07-19

Review date:2004-10-14

Drafting unit:beijing light bulb factory

Focal point unit:National Technical Committee for Standardization of Lighting Appliances

Publishing department:State Bureau of Technical Supervision

competent authority:China Light Industry Federation

Introduction to standards:

This standard specifies the types and dimensions of bayonet lamp holders. This standard applies to the types and dimensions of bayonet lamp holders for electric light sources. GB 1407-1996 Types and dimensions of bayonet lamp holders GB1407-1996 Standard download decompression password: www.bzxz.net

Some standard content:

GB1407-1996
This standard is equivalent to the negative contents of 7004-8-1, 7004-9-1, 7004-10-6, 7004-10A-2, 7004-11A-8, 7004-11B7, 7004-11C-2, 7004-11D-1, 7004-12-7, 7004-13-4, 7004-14-7, 7004-15-2, 7004-17-3, 7004-18-1, 7004-19-1 of IEC61-1Q "Lamp holders, lampholders and test standards for their safety and interchangeability - Part 1: Lamp holders" (revised in November 1994).
The B9s/14, B129/12, B12s/13, B22s/29X26 and B22d/30×30 in the original GB1407-78 "Types and Dimensions of Plug-in Lamp Holders" are not the specifications in IFC61-1Q, so they are cancelled in this standard. After the implementation of this standard, the original GB1407-78 "Types and Dimensions of Plug-in Lamp Holders" will be abolished.
This standard is proposed by China Light Industry General Association.
This standard is under the jurisdiction of the National Electric Light Source Standardization Center. This standard was drafted by Beijing Electric Light Source Research Institute. The main drafters of this standard are Wang Yinquan and Jie Tianrui. ..comGB 1407- 1996
EC Preface
1. The formal resolutions or agreements of the International Technical Committee on technical issues are drafted by the technical committees with representatives of the national committees that have special interests in the issue. It expresses the international consensus on the issues studied as much as possible. 2. These resolutions or agreements take the form of recommended standards for international use and, in this sense, are accepted by the national committees.
3. In order to promote international unification, the International Electrotechnical Commission hopes that countries that do not have national standards yet will adopt the recommended standards of the International Electrotechnical Commission as the basis for formulating their national standards when national conditions permit. 4. The International Electrotechnical Commission requires national committees to strive to coordinate their national standards with the recommended standards cabinet when national conditions permit, so as to promote international consistency on these issues. ..com1 Standard
National Standard of the People's Republic of China
Types and dinientions of hayunet amp caps
Types and dinientions of hayunet amp caps This standard specifies the types and dimensions of bayonet lamp caps. This standard applies to the types and dimensions of bayonet lamp caps for electric light sources. 2 Referenced standards
GB 14071996
eqyIEc61-1Q:1994
Replacement GB 143778
The provisions contained in the following standards constitute the provisions of this standard through reference in this standard. When this standard is published, the versions shown are valid. All standards will be revised, and parties using this standard should explore the possibility of using the latest version of the following standards. QB2218-1996 Nomenclature of lamp holders and lampholders 3 Types and dimensions
3.1 The type of lamp holder shall comply with the provisions of QB2218-1996. 3.2 The type and dimensions of bottom-end lamp holders shall comply with the provisions of Figures 1 to 15 and Tables 1 to 15 BA75
BA9s/13. BA9s/14
BAZ15d
BA15s-3(100°/135\)
RAX15d
BAU159
PA21-3(120\)
B22d(90/136°)
See Figure 1 and Table]
See Figure 2 and Table 2
See Figure 3 and Table 3
See Figure 4 and Table 4
See Figure 5 and Table 5
See Figure 6 and Table 6
See Figure 7 and Table 7
See Figure 8 and Table 8
See Figure 9 and Table 9
See Figure 10 and Table 10
See Figure 11 and Table 11
See Figure 12 and Table 12
See Figure 13 and Table 13
See Figure 14 and Table 14
See Figure 15 and Table 15
Approved by the State Administration of Technical Supervision on September 5, 1996, implemented on September 1, 1997
Excluding solder
Including smelting
GB 14071996
The attached figure only shows the inspection scale, the unit is mmBA7s/11
11. 5±0.3
The angle between the tip and the lamp holder
It can be a right angle and the maximum can be 105
The lamp holder can be ridiculed, and its diameter is not allowed to exceed the maximum value of the lamp holder without a flared mouth, 5 t, Table 1
Dimensions represent symbols
Minimum value
Unassembled lamp cap
Nominal a0
Maximum value
Lamp cap on finished lamp
Minimum value
Nominal 30°
1) Both the maximum and minimum values ​​of A are measured within the minimum range shown in N. Below the range shown in N, only the maximum value of A is limited. Maximum value
BA9s/13
GB1407www.bzxz.net
The attached figure only shows the inspection dimensions, the unit is mm13.1±0.2
Excluding solder
Including solder
The lamp cap can be a bell mouth, and its diameter is not allowed to exceed the maximum 0.5 mm of the lamp cap without a suction port. Table 2
Dimensions Symbols
Minimum
Unassembled lamp cap
Maximum
D, 241
BA9s/14
14.0±0.25
Lamp cap on finished lamp
Minimum
Maximum
I) The maximum value of A is measured within the small range shown by N. Below N, only the maximum value of A is limited. 9.25
GB1407-1996
As required
Recommended height: 14mm
Including solder
Excluding welding
The lamp cap may be flared, and its diameter is not allowed to exceed the maximum value of the lamp cap without flare by 0.5mm. Table 3
Dimension representative symbol
Minimum value
Unassembled lamp holder
Maximum value
Nominal 150°
Lamp holder on product lamp
Minimum value
Nominal 150°
1) The maximum and minimum values ​​of A should be measured within the minimum range shown in N. Below the range shown in N, only the maximum value of A is limited. Maximum value GB 1407—1996 Determined as needed Recommended width: 14 mm Excluding solder Including solder The lamp cap may be flared or larger, and its diameter is not allowed to exceed the maximum value of the lamp cap without flare by 0.5 mm. Table 4 Dimensional symbols Large diameter Unassembled lamp cap Maximum value Number 120° Lamp cap on assembled lamp Minimum value Nominal 120° Maximum value 1) Both the maximum and minimum values ​​of A shall be measured within the range shown in N. Below the range shown in N, only A is limited. Maximum value. Excluding solder
Including solder
GB1407-1996
According to the micro requirements
Recommended height, 1.5mm±0.25tm, 15.0mm:t0.25ma, 21.0mm-0.25mm lamp holder can be thiophene port, H diameter is not allowed to exceed the maximum value of the lamp holder without thiophene 1. 00mm, 3415d
Sleeve-shaped contact
Face-shaped tip
All other dimensions are the same as BA75d
Dimension symbol
Minimum value
GB1407-:1996
Unassembled lamp holder
Maximum value
Near false 9
Nominal 90°
Lamp holder on finished lamp
Minimum value
Nominal 90″
1) The maximum and minimum values ​​of A should be measured within the range shown in N. Within the range shown in N, 5 limits the maximum value of A. 2) For the lamp holder on the finished lamp with bone-shaped contact, the height difference between the two contacts with solder shall not exceed F0.nun, maximum value
excluding solder
including solder
reference pin
GB 1407-1996
as required
recommended value: 18mm.13mm.21mm
the head can be a bell mouth, and its diameter is not allowed to exceed the maximum value of the lamp holder without bell mouth by 1.00mm: BAY15d
planted round lamp
round lamp
HAYT5s
all other relevant dimensions are
alternate with BAYI5d lamp holder
symbol in the scale
minimum
GB1407-1996
unassembled lamp holder
maximum value
15, 25
Reverse 9
Nominal Sr
Lamp holder on finished lamp
Minimum value
1) The maximum and minimum values ​​of A shall be measured within the minimum range shown in N. Within the range shown in N, only the maximum value of A shall be limited. 2) For the lamp holder on the finished lamp with strip contacts, the difference in height between the two contacts with materials shall not exceed 0.5mml. Maximum value
Including solder
Reference pins
GB1407-1996
BAZI5d
According to requirements
Required height: 19.cmm, 3.25mm, 21.0mm±0.25mal. The lamp holder can be a flare. Its diameter is not allowed to exceed the maximum value of the lamp holder without a flare 1.c0mm, round contact
Contact
Does not include solder
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.