title>GB 10408.7-1996 Ultrasonic and passive infrared composite intrusion detector - GB 10408.7-1996 - Chinese standardNet - bzxz.net
Home > GB > GB 10408.7-1996 Ultrasonic and passive infrared composite intrusion detector
GB 10408.7-1996 Ultrasonic and passive infrared composite intrusion detector

Basic Information

Standard ID: GB 10408.7-1996

Standard Name: Ultrasonic and passive infrared composite intrusion detector

Chinese Name: 超声和被动红外复合入侵探测器

Standard category:National Standard (GB)

state:Abolished

Date of Release1996-10-23

Date of Implementation:1997-05-01

Date of Expiration:2005-10-14

standard classification number

Standard ICS number:Environmental Protection, Health and Safety>>13.310 Prevention of Criminal Behavior

Standard Classification Number:Comprehensive>>Social Public Security>>A91 Security Alarm System

associated standards

alternative situation:void; void;

Procurement status:IEC 839-2-1990,EQV;UL 639-1984,EQV

Publication information

other information

Review date:2004-10-14

Drafting unit:Shanghai China Resources Defu Optoelectronics Co., Ltd.

Focal point unit:National Security Alarm System Standardization Technical Committee

Publishing department:State Bureau of Technical Supervision

competent authority:Ministry of Public Security

Introduction to standards:

This standard specifies the technical requirements and test methods for ultrasonic and passive infrared composite intrusion detectors in intrusion alarm systems, and is the basic basis for design, manufacturing and inspection. This standard applies to ultrasonic and passive infrared composite intrusion detectors installed in buildings. GB 10408.7-1996 Ultrasonic and passive infrared composite intrusion detector GB10408.7-1996 Standard download and decompression password: www.bzxz.net

Some standard content:

— 1996 | It has strong anti-interference ability, thereby reducing the false alarm rate of the detector. This standard is part of the GB10408 "Intrusion Detector" series of standards. The format of this standard refers to GB10408.6-91 "Microwave and Passive Infrared Composite Intrusion Detector", and the technical requirements and test methods adopt GB10408.1-89 "General Technical Conditions for Intrusion Detectors" GB10. 408.2-89 "Ultrasonic Intrusion Detector" and GB10408.5---89 "Passive Infrared Intrusion Detector" relevant chapters and articles.
There is currently no international standard for this type of product. This standard adopts IEC839-2:1990 "Requirements for Intrusion Alarm Systems" in terms of sensitivity and detection range, resistance to hot air flow interference and resistance to small animal interference, and test methods. In terms of methods, the relevant provisions of UI.639 (1984 version) "Intrusion Detector" are equivalently adopted. This standard is proposed by the Ministry of Public Security of the People's Republic of China. This standard is under the jurisdiction of the National Security Alarm System Standardization Technical Committee. This standard is drafted by Shanghai China Resources-Defu Optoelectronics Co., Ltd. The main drafter of this standard is Huang Keyi.
553
National Standard of the People's Republic of China
Combination ultrasonic & passive infrared intrusion detector1 range
GB 10408.7—1996||tt ||This standard specifies the technical requirements and test methods for ultrasonic and passive infrared composite intrusion detectors (referred to as composite detectors/composite units) in intrusion alarm systems. It is the basic basis for design, manufacturing and inspection. This standard applies to ultrasonic and passive infrared composite intrusion detectors installed in buildings. 2 Referenced standards
The provisions contained in the following standards constitute provisions of this standard by being quoted in this standard. At the time of publication, the editions indicated were valid. All standards are subject to revision and parties using this standard should explore the possibility of using the latest version of the standard listed below. GB10408.1-89 General technical conditions for intrusion detectors GB10408.2-89 Ultrasonic intrusion detectors GB10408.5-89 Passive infrared intrusion detectors 3 definitions
This standard adopts the following definitions:
3.1 Ultrasonic The combination ultrasonic & passive infrared intrusicon detector combines ultrasonic Doppler detection and passive infrared detection units into one, and when both sense the movement of the human body and are in an alarm state within a set time interval A device that only sends out an alarm signal. 3.2 Ultrasonic unit: Ultrasonic unit is the general term for ultrasonic transmitter, ultrasonic receiver and signal processing circuit unit. 3.3 Passive infrared units passive infrared units is the general term for infrared optical systems, sensors and infrared signal processing circuit units. 3.4 Detection range coverage area
The detection range of the composite detector is the overlapping area of ??the detection ranges of the ultrasonic and passive infrared units. 4 General requirements
4.1 The composite detector should be composed of an ultrasonic unit, a passive infrared unit and a signal processor, and be installed in the same casing. 4.2 The detection ranges of ultrasonic and passive infrared should be of equal size and overlap. There should be devices for adjusting the detection range and adjusting the overlap.
4.3 Go
The ultrasonic unit, passive infrared unit and composite unit can all be tested individually. 5 Technical Requirements
5.1 Appearance and Mechanical Structure Requirements
Approved by the State Bureau of Technical Supervision on 1996-10-23 554
Implemented on 1997-05-01
GB 10408.7—1996
should comply with the requirements of 4.1 in GB10408.1 and 4.4 in GB10408.5. 5.2 Performance requirements
5.2.1 Electrical performance requirements
shall comply with the requirements of 4.2 in GB10408.1, of which 4.2.4 sensitivity and detection range shall comply with the requirements of 5.2.2. 5.2.2 Sensitivity and detection range
5.2.2.1 Sensitivity
The reference target is at the boundary of the detection range on the central axis directly in front of the detector, at a speed of one step per second (about 0.75m/s) , when moving toward the detection range in a direction of 45° along the central axis, an alarm state should occur if the moving distance is less than 3m. For those with a nominal detection distance less than 10m, an alarm state should be generated when the moving distance is less than 30% of the detection distance. 5.2.2.2 Detection range
Under specified environmental conditions, the maximum detection range of the composite detector shall not be less than the nominal value of product performance, but shall not exceed 25% of this value.
5.2.2.3 Detectable speed
The detectable speed range of the composite detector should be 0.3~3m/s. 5.2.2.4 Response to intermittent movement
The composite detector should be able to detect the intermittent movement of the reference target. Its moving time is not less than 1s, its moving speed does not exceed the detectable speed range, and its non-moving time does not exceed 5s.
5.2.2.5 The alarm duration and recovery after the alarm state shall comply with the requirements of 4.1.1 and 4.1.3 in GB10408.5. 5.2.3 Dual detection function
When the composite detector senses human intrusion and the ultrasonic unit and passive infrared unit are both in alarm status, they should be able to send out alarm signals and instructions.
When only one of the ultrasonic unit or passive infrared unit in the composite detector is disturbed and is in an alarm state, the composite detector shall not send out an alarm signal.
5.2.4 Self-checking function
The composite detector should have a self-checking function. When the ultrasonic unit fails, it should be able to produce a fault signal indication and output, and be able to automatically switch to the detection state of the passive infrared unit. If three intrusions occur, the composite detector should be able to send out an alarm signal. Its sensitivity and detection range should meet the requirements of 5.2.2.
5.2.5 Test device
The following test devices should be included in the composite detector: a) Walking test indicator light
The detector should be equipped with a walking test indicator light, which is used during installation Commissioning of warning areas as well as indication of on-site disturbances and own faults. After the walking test, all indicator lights should be turned off or blocked. The indicator lights should be displayed in three colors. It is recommended that ultrasonic is yellow, infrared is green, and composite is red.
b) Both the ultrasonic unit and the passive infrared unit should have their own signal test points to detect sensitivity, determine the detection range and check the working status of the unit.
5.3 Environmental adaptability requirements
should comply with the requirements of 4.3 Group I in GB10408.1. 5.4 Stability
Under the environmental conditions specified in 6.1 of this standard, the sensitivity of the detector shall be adjusted according to the requirements of 5.2.2 and fixed. After seven days of continuous operation, the change in the detection distance of the composite detector shall not change. Greater than 10%, during this period the composite detector should not produce false alarms or missed alarms.
5.5 Anti-interference requirements
555
5.5.1 Anti-hot air flow interference
GB 10408.7--1996
Composite detectors and their ultrasonic and passive All infrared units shall comply with the requirements of 4.6.2 in GB10408.1 respectively. 5.5.2 Anti-small animal interference
composite detector and its ultrasonic and passive infrared units shall respectively comply with the requirements of 4.1.6 in GB10408.5. 5.5.3 Anti-electromagnetic interference
composite detector and its ultrasonic and passive infrared units shall respectively comply with the requirements of 4.6.1 in GB10408.1. 5.5.4 Anti-environmental interference
The composite detector and its ultrasonic and passive infrared units are not affected by the interference of any moving objects beyond 25% of the detection range and may cause false alarms.
Composite detectors and passive infrared units should not be affected by building motion sources and cause false alarms. 5.5.5 Anti-light interference
The composite detector and its passive infrared unit shall comply with the requirements of 4.3.1 in GB10408.5. 5.5.6 Anti-noise interference
The composite detector and ultrasonic unit should be able to withstand the interference of electric ringing without generating an alarm state. 5.6 Durability
should comply with the requirements of 4.5 in GB10408.1. 5.7 Safety
5.7.1 Ultrasonic sound intensity limit
should comply with the requirements of 4.3 in GB10408.2. 5.7.2 Flame retardant requirements
should comply with the requirements of 4.7.3 in GB10408.1. 5.8 Reliability
shall comply with the requirements of 4.9 in GB10408.1. 6 Test method
6.1 Test conditions
6.1.1 The detector should be installed according to the requirements of the product manual. If the sensitivity is adjustable, adjust it to the maximum position and remain unchanged during the test. If a range of installation height is given, it should be tested separately at its upper and lower limits. If a pulse counting option is provided, it should also be tested separately under various selection states.
6.1.2 The test should be conducted in the specified indoor environment. The background temperature of the detector's field of view is between 20 and 25°C and is evenly distributed. It should be maintained constant throughout the test. The total change of the background surface temperature It should be no more than 1℃, the relative humidity is 45%~75%RH, and the atmospheric pressure is 86~~106 kPa.
6.1.3 The test site should be more than 3m larger than the detection range. 6.2 Appearance and structural performance test
shall be carried out in accordance with the provisions of 5.2 in GB10408.1, and the test results shall meet the requirements of 5.1. 6.3 Performance test
6.3.1 Electrical performance test
shall be carried out in accordance with the provisions of 5.3 in GB10408.1, of which the sensitivity and detection range tests in 5.3.4 shall be carried out in accordance with the provisions of 6.3.2. 6.3.2 Sensitivity and detection range test
6.3.2.1 Sensitivity test
On the detection range boundary on the central axis directly in front of the detector marked in the product manual, the reference target is measured at 0.75m/s The speed is in the direction of 45° with the central axis, moving within the detection range, reciprocating once to the left and right, with a moving distance of 3m or 30% of the nominal detection distance (whichever is smaller), ultrasonic, passive infrared and composite The unit should generate an alarm state, and the test results should meet the requirements of 5.2.2.1. 556
6.3.2.2 Detection range test
GB 10408.7—1996bzxZ.net
Gradually increase the radial test distance at the boundary point of the above central axis and measure the detector according to the method of 6.3.2.2 the maximum detection range. The test results shall comply with the requirements of 5.2.2.2. 6.3.2.3 Detection speed test
Stand on the boundary of the detection range directly in front of the detector, with three speeds of 0.3m/s, 2.0m/s, and 3.0m/s in a direction of 45° to the central axis. Moving within the detection range and reciprocating once to the left and right should generate an alarm state. The test results shall comply with the requirements of 5.2.2.3. 6.3.2.4 Intermittent movement response test
The reference target is at the boundary of the detection range directly in front of the detector, in a direction of 45° with the central axis within 1s, and within the detection range at a speed of 0.75m/s Move 1m, stop for 5 seconds, and continue moving forward to repeat the process. The composite detector shall generate an alarm state before the reference target moves 5m or 50% of the nominal detection distance (whichever is smaller). The left and right reciprocates once, and the test results should meet the requirements of 5.2.2.4.
6.3.2.5 The alarm duration and alarm state recovery test shall be carried out in accordance with the provisions of 5.2.3 in GB10408.5, and the test results shall comply with the requirements of 5.2.2.5. 6.3.3 Dual-detection function test
Use the walking test indicator light to conduct the following tests: a) The infrared sensor is directly irradiated by the alternating heat source so that the passive infrared unit is in the alarm state but the ultrasonic unit does not alarm. Observe the composite alarm state;| |tt||b) The ultrasonic sensor is interfered by strong normal temperature airflow, causing the ultrasonic unit to be in an alarm state, but the passive infrared unit does not alarm. Observe the composite alarm state.
The above test is repeated five times, and the time interval between each time is not less than 1 minute, and should comply with the requirements of 5.2.3. 6.3.4 Self-check function test
Carry out the test according to the method provided by the product standard, and the test results should meet the requirements of 5.2.4. 6.3.5 Test device inspection
During the walking test, the test device shall be inspected, and the results shall comply with the requirements of 5.2.5. 6.4 Environmental test
shall be carried out in accordance with the provisions of 5.4 in GB10408.1, and the test results shall meet the requirements of 5.3. 6.5 Stability test
The test is only conducted in the composite state according to the provisions of 5.4. Record the number of alarms during the test, and conduct at least two alarm function tests at any position in the detection range every day. The test results should meet the requirements of 5.4. 6.6 Anti-interference test
6.6.1 Hot air flow interference
Place a 500W hot air blower 1m below and 1m in front of the detector. The airflow is directed towards the detector at an angle of 12° from the horizontal plane and blows through it. The gas flow rate on the surface of the detector is 1.5m/s ± 0.2m/s, lasts for 5 minutes, and is turned off for 5 minutes. A total of 3 tests are conducted. The test results should meet the requirements of 5.5.1.
6.6.2 Small animal interference
Small animal interference is simulated with a metal rod with a length of 150mm and a diameter of 30mm. The metal surface is blackened to make the specific emissivity close to 0.9, and there is electric heating inside the rod. When the component is energized, the surface temperature of the metal rod is 4 to 5°C higher than the ambient temperature. Place the rod horizontally on a small non-metallic frame with a height of no more than 100mm from the ground. The frame is dragged with a non-metallic thin wire and moved repeatedly 5 times at different distances within the detection range at a speed of 1m/s ± 0.5m/s. The test results shall comply with the requirements of 5.5.2. 6.6.3 Electromagnetic interference
shall be carried out in accordance with the provisions of 5.7.1 in GB10408.1 + the test results shall comply with the requirements of 5.5.3. 6.6.4 Environmental interference
a) The reference target moves outside the boundary of the area beyond 25% of the detection range, and observes the ultrasonic, passive infrared and composite alarm status: 557
GB 10408.7-1996||tt ||b) For capsule motion interference, install the product on the center of a 1800mm×1000mm×20mm plywood board. According to the installation method when using the product, reliably fix the board to the wall or the ground so that the detector can be used during the test. Neither the board nor the board moves. The detector is in an alert state. Use a steel ball with a diameter of 50mm (weight 0.51kg) to fall freely from a height of 775mm or swing in an arc to hit the center of the back of the board on which the detector is installed (see Figure 1). Observe passive infrared and composite alarm status. The above test results should comply with the requirements of 5.5.4. Steel ball
O
Steel ball
Detector
Horizontal installation
Vertical installation
Figure 1 Vibration interference test device diagram|| tt||6.6.5 Light interference
Follow the provisions of 5.4.1 in GB10408.5, and the test results should meet the requirements of 5.5.5. 6.6.6 Bell interference
Follow the provisions of 5.3.2 in GB10408.2 and observe the alarm status of the ultrasonic unit. The test results shall comply with the requirements of 5.5.6.
6.7 Durability test
Perform according to the provisions of 5.6 in GB10408.1, and the test results should meet the requirements of 5.6. 6.8 Safety test
6.8.1 Ultrasonic transmitter sound intensity measurement
Use a sound level meter to measure the sound pressure according to the provisions of 5.7.1, and the measurement results should meet the requirements of 5.7.1. 6.8.2 Flame retardant test
shall be carried out in accordance with the provisions of 5.8.3 in GB10408.1, and the test results shall comply with the requirements of 5.7.2. 6.9 Reliability test
shall be carried out in accordance with the provisions of 5.10 in GB10408.1, and the test results shall meet the requirements of 5.8. 7 Inspection rules
According to GB10408.The provisions of Chapter 6 in 1 shall be implemented. The test items and sequence are as specified in Table 1. 558
Serial number
1
2
3
4
5
6
7| |tt||8
10
11
12
13
15
16
17||tt ||18
19
20
21
22
23
24
25
26
27
Item
Appearance
Shell protection level
Shell strength
Bending test
Tensile test|| tt||Functional test
Double detection function
Self-test function
Test device inspection
Overcurrent protection
Tamper protection
Sensitivity and detection range
Power supply scope
Overvoltage operation
Power consumption
Backup power supply
Interface check
High temperature|| tt||Constant mixing
Low temperature
Low temperature purchase and storage
Vibration
Strike
Free fall
Stability||tt ||Durability
Thermal flow interference
GB 10408.7-1996
Table 1
Technology
Requirements
5.1||tt| |5.1
5.1
5.1
5.1
5.2.1
5.2.3
5.2.4
5.2 .5
5.2.1
5.2.1
5.2.2
5.2.1
5.2.1
5.2.1
5.2.1
5.2.1
5.3
5.3
5.3
5.3
5.3||tt| |5.3
5.3
5.4
5.6
5.5.1
Test project
Test
Method||tt ||6.2
6.2
6.2
6.2
6.2
6.3.1
6.3.3
6.3. 4
6.3.5
6.3.1
6.3.1
6.3.2
6.3.1
6.3.1| |tt||6.3.1
6.3.1
6.3.1
6.4
6.4
6.4
6.4||tt ||6.4
6.4
6.4
6.5
6. 7
6.6.1
Unqualified
Classification
C
B
B
c
C
B
B
B|| tt||B
B
B
B
B
C
C
B||tt| |B
B
B
B
B
B
E
B
B
B
Identification
Inspection
V
V
V
Group A
Consistent quality Sex test
Group B
Group C
V
Group D
559
Serial number
28||tt ||29
30
31
32
33
34
35
item
Small animal interference
Electromagnetic interference
Environmental interference
Light interference
Bell interference
Ultrasonic sound intensity measurement
Flame retardant||tt ||Reliability
Note: Those with " and \ in the table indicate ongoing projects. Marking, packaging, transportation and storage
8
GB 10408.7-1996
Table 1 (End)
Technical
Requirements
5.5 .2
5.5.3
5.5.4
5.5.5
5.5.6
5.7.1
5.7.2
5.8
Follow the provisions of Chapter 7 of GB10408.1. 9 Requirements for product instructions
Test
Method
6.6.2
6.6.3
6.6.4
6.6.5
6.6. 6
6.8.1
6.8.2
6.9
Unqualified
Classification
B| |tt||B
B
B
B
Identification
Inspection
Group A
Quality consistency Inspection
Group B
Group C
Group D
In addition to the detection function and technical performance indicators (including operating power supply voltage and power consumption), the product manual of the composite detector provides , wiring diagram and installation instructions, the following content should also be included: a) The detection ranges of ultrasonic, passive infrared and composite are represented by different lines (or colors) on the same top view and side view respectively; ||tt| |b) The basic principles and usage of the self-test function; c) How to use the walking test device;
d) Precautions to avoid missed alarms and false alarms. 560
1
Unqualified
Classification
C
B
B
c
C
B
B
B
B
B
B
B
B
C|| tt||C
B
B
B
B
B
B
B||tt| |E
B
B
B
Authentication
Inspection
V
V
V
Group A
Quality consistency inspection
Group B
Group C
V
Group D
559| |tt||Serial number
28
29
30
31
32
33
34||tt ||35
item
small animal interference
electromagnetic interference
environmental interference
light interference
bell interference
Ultrasonic sound intensity measurement
Flame retardant
Reliability
Note: Those with " and \ in the table indicate the projects being carried out. Marking, packaging, transportation and storage
8
GB 10408.7-1996
Table 1 (End)
Technical
Requirements
5.5.2
5.5.3||tt ||5.5.4
5.5.5
5.5.6
5.7.1
5.7.2
5.8
According to GB10408 .1 The provisions of Chapter 7 are implemented. 9 Requirements for product instructions
Test
Methods
6.6.2
6.6.3
6.6 .4
6.6.5
6.6. 6
6.8.1
6.8.2
6.9
Unqualified||tt ||Classification
B
B
B
B
B
Identification
Inspection
Group A
Quality consistency inspection
Group B
Group C
Group D
In addition to the detection function and technical performance, the product manual of the composite detector In addition to indicators (including operating power supply voltage and power consumption), wiring diagrams and installation instructions, the following content should also be included: a) The detection ranges of ultrasonic, passive infrared and composite are represented by different lines (or colors) on the same picture. Top view and side view;
b) Basic principles and usage of the self-test function; c) How to use the walking test device;
d) Precautions to avoid missed alarms and false alarms. 560
1
Unqualified
Classification
C
B
B
c
C
B
B
B
B
B
B
B
B
C|| tt||C
B
B
B
B
B
B
B||tt| |E
B
B
B
Authentication
Inspection
V
V
V
Group A
Quality consistency inspection
Group B
Group C
V
Group D
559| |tt||Serial number
28
29
30
31
32
33
34||tt ||35
item
small animal interference
electromagnetic interference
environmental interference
light interference
bell interference
Ultrasonic sound intensity measurement
Flame retardant
Reliability
Note: Those with " and \ in the table indicate the projects being carried out. Marking, packaging, transportation and storage
8
GB 10408.7-1996
Table 1 (End)
Technical
Requirements
5.5.2
5.5.3||tt ||5.5.4
5.5.5
5.5.6
5.7.1
5.7.2
5.8
According to GB10408 .1 The provisions of Chapter 7 are implemented. 9 Requirements for product instructions
Test
Methods
6.6.2
6.6.3
6.6 .4
6.6.5
6.6. 6
6.8.1
6.8.2
6.9
Unqualified||tt ||Classification
B
B
B
B
B
Identification
Inspection
Group A
Quality consistency inspection
Group B
Group C
Group D
In addition to the detection function and technical performance, the product manual of the composite detector In addition to indicators (including operating power supply voltage and power consumption), wiring diagrams and installation instructions, the following content should also be included: a) The detection ranges of ultrasonic, passive infrared and composite are represented by different lines (or colors) on the same picture. Top view and side view;
b) Basic principles and usage of the self-test function; c) How to use the walking test device;
d) Precautions to avoid missed alarms and false alarms. 560
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.