HG/T 20519.4-1992 Home Page HG/T20519.4-1992 Standard Download Decompression Password: www.bzxz.net
Some standard content:
Home Page Drawing HG 20519.4-92 Home Page Drawing HG 20519.4-92 In the process design construction drawing, some of the regulations used in the design are drawn into the home page drawing in the form of diagrams to better understand and use each design document. The home page drawing includes the following contents: 1 Legends, symbols, equipment position numbers, material codes and pipeline numbers used in pipeline and instrument flow charts. For details, see the relevant design regulations: HG20519.30-92, HG20519.31-92, HG20519.32-92, HG2C519.3592, HG20519.36-92, HG20519.37-92. 2 Codes and numbers of devices and main items. 3 Legends, symbols, codes, etc. of the detection and control systems used in the process of automatic control (instrumentation) specialty. 4 Other matters that need to be explained. www.bzxz.net The size of the drawing can be determined according to the content and shall not be larger than A1. See the example diagram for details Screw mouth Wall outlet bag Equipment position number 1Equipment category code 2Main item number 3Equipment sequence number in the same type of equipment 4Same equipment suffix Equipment category code Compressor, fan Heat exchanger Reactor Main item code and number of synthetic ammonia unit [Main item name·code Pipeline and instrument flow Diagram (PID) sequence number The first letter of the letter code of the measured variable and instrument function Measured variable||tt ||Conductivity Modifier Ratio (fraction) Manual (manual trigger) Moisture or humidity Pressure or vacuum Quantity or number of pieces Radioactivity Velocity or rate Subsequent letters Test point (joint) Integration and integration Integration, integration Record or print Method of indicating graphic symbols Measurement point Graphic number indicating the installation position of the instrument Installation position Graphic symbol Abbreviation of the Chinese characters||tt| |When energy is interrupted Valve is in the closed position and When energy is interrupted Valve is in the original position When energy is interrupted Valve is in the open position and Highest (higher) Lowest (lower) Method of indicating the liquid level gauge in glass tube Nitrogen recovery Hydrogen recovery Out-of-boundary pipeline Code of synthetic ammonia unit: 670 Main item codes of other related units Out-of-plant pipeline Thermal power station Desalted water station Nitrogen and oxygen station Circulating water pump room Sewage treatment station| |tt||Urea plant Measurement point Graphic symbol indicating the installation position of instrument Installation position Installation of instrument on site Centralized instrument panel Installation of instrument Installation of instrument on site Graphic symbol Connection and signal line Process connection or mechanical connection line Pneumatic signal line Electric signal line Home page diagram (Example diagram) Design project Design stage ××××- ×××-××-1 Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.