title>JB/T 5332.2-1991 Electric submersible pump cables with rated voltage up to and including 3.6/6kV Part 2: Electric submersible pump lead-in cables - JB/T 5332.2-1991 - Chinese standardNet - bzxz.net
Home > JB > JB/T 5332.2-1991 Electric submersible pump cables with rated voltage up to and including 3.6/6kV Part 2: Electric submersible pump lead-in cables
JB/T 5332.2-1991 Electric submersible pump cables with rated voltage up to and including 3.6/6kV Part 2: Electric submersible pump lead-in cables
Basic Information
Standard ID:
JB/T 5332.2-1991
Standard Name: Electric submersible pump cables with rated voltage up to and including 3.6/6kV Part 2: Electric submersible pump lead-in cables
This standard specifies the product varieties, technical requirements and tests of the lead-in cables for electric submersible pumps. This standard applies to lead-in cables for electric submersible (including submersible and submersible brine) pump units with rated voltages of 3.6/6KV and below. The lower end of the lead-in cable is connected to the submersible motor junction box, and the upper end is connected to the feeder cable. JB/T 5332.2-1991 Cables for electric submersible pumps with rated voltages of 3.6/6kV and below Part 2 Lead-in cables for electric submersible pumps JB/T5332.2-1991 Standard download decompression password: www.bzxz.net
Some standard content:
Mechanical Industry Standard of the People's Republic of China JB/T 5332.2-1991 Electric submersible pump cables with rated voltages up to and including 3.6/6kV Part 2: Electric submersible pump lead-in cables Published on 1991-06-28 Implementation by the Ministry of Machinery and Electronics Industry of the People's Republic of China on 1992-07-01 Mechanical Industry Standard of the People's Republic of China Electric submersible pump cables with rated voltages up to and including 3.6/6kV Part 2 Subject content and scope of application Electric submersible pump lead-in cables This standard specifies the product varieties, technical requirements and tests for electric submersible pump lead-in cables. JB/T5332.2-1991 This standard applies to lead-in cables for electric submersible (including submersible and submersible brine) pump units with rated voltages up to and including 3.6/6kV. The lower end of the lead-in cable is connected to the submersible motor junction box, and the upper end is connected to the power cable for feeding. In addition to complying with the provisions of this standard, the cable shall comply with the requirements of JB5332.1 "General provisions for cables of electric submersible pumps with rated voltages of 3.6/6kV and below". 2 Usage characteristics 2.1 Rated voltage U. /U is 1.8/3kV and 3.6/6kV2.2 The long-term allowable operating temperature of the cable conductor and the allowable ambient temperature underground are as specified in Table 2. 3 Model The model of the cable is as shown in Table 1. WQJYEN10 WQJYEE10 WQJYEH10 WQJYEQ10 WQJYFQ10 4 specifications Polyimide fluorine 46 composite film/EPR composite insulation butyl rubber inner sheath bare steel belt interlocking cone submersible pump lead cable Polyimide fluorine 46 composite film/EPR composite insulation EPR Inner sheath bare steel belt interlocking submersible oil pump lead-in rope polyimide 1F46 composite film/EPR rubber combined insulation oxygen-sulfonated polyethylene inner sheath bare steel belt interlocking submersible oil pump lead-in rope polyimide 1F46 composite film/EPR rubber combined insulation lead inner sheath bare steel belt interlocking submersible oil pump lead-in rope polyimide 1F46 composite film/fusible polytetrafluoroethylene combined insulation lead inner sheath bare steel belt interlocking submersible oil pump lead-in rope The specifications of the cable are shown in Table 2. Rated voltage WQJYEN10 WQJYEE10 WQJYEH10 WQJYEQ10 WQJYFQ10 Approved by the Ministry of Machinery and Electronics Industry on June 28, 1991. Nominal cross-section 10.0, 13.2, 16.0, 20.0 10.0, 13.2, 16.0, 20.0 Long-term allowable working temperature of cable conductor and rated ambient temperature 20C insulation resistance Implementation on July 1, 1992 Technical requirements The cable structure dimensions are specified in Table 3. Rated voltage Nominal cross section Conductive wire corebzxz.net Number of roots/single wire Nominal diameter 1/3.67 1/4.50 JB/T5332.2-1991 Nominal insulation Thickness 1) Inner sheath Nominal thickness Combined insulation does not include the thickness of polyimide-fluorine 46 composite film. Note: 1) Cable technical requirements shall comply with the provisions of Table 4. Tests shall be in accordance with the provisions of Table 4. Structural dimensions Insulation originality Inner sheath thickness Oil cushion Armor layer Overall dimensions Electrical properties of cable Conductor resistance Insulation resistance Voltage test Leakage current 4h high voltage test Physical and mechanical properties of cable Physical and mechanical properties of insulation Physical and mechanical properties of inner sheath Special properties Sealing performance of stranded conductor High temperature and high pressure performance Bending performance of armor layer Nominal steel belt! Cable shape 12×30 13×36 15×39 DC resistance of conductor at 20C Test type Conform to Article 4.2 of JB5332.1 and Article 5.1 of this standardConform to Article 4.3 of JB5332.1 and Article 5.1 of this standardConform to Article 4.5 of JB5332.1 and Article 5.1 of this standardConform to Article 4.6 of JB5332.1 Conform to Article 4.9.1 of GB2952 and JB5332.1Conform to Article 5.1 of this standard Conform to Table 3 of this standard Conform to In accordance with the provisions of Table 2 of this standard In accordance with the provisions of Article 410.9 of JB5332.1 In accordance with the provisions of Article 4.10.4 of JB5332.1 In accordance with the provisions of Article 4.10.10 of JB5332.1 In accordance with the provisions of Article 4.3.2 and 4.3.3 of JB5332.1 In accordance with the provisions of Article 4.5 of JB5332.1 In accordance with the provisions of Article 4.10.6 of JB5332.1 In accordance with the provisions of Article 4.10.5 of JB5332.1 Note: St is a periodic sampling test, which is stipulated in this standard as 12 months. Additional remarks: This standard is proposed and managed by Shanghai Cable Research Institute of the Ministry of Machinery and Electronics Industry. T, s GB2952 JB5332.1 Appendix J GB2951 GB2951 JB5332.1 Appendix E JB5332.1 Appendix F JB5332.1 Appendix G This standard was drafted by Shanghai Cable Research Institute of the Ministry of Machinery and Electronics Industry, Tianjin Cable Factory, Shenyang Cable Factory and other units. The main drafters of this standard are Xiang Peng, Xi Zhongbo and Wang Guozhong. 2 People's Republic of China Mechanical Industry Standard Electric submersible pump cables with rated voltage up to and including 3.6/6kV Part 2 Electric submersible pump lead-in cables JB/T5332.21991 Published and distributed by the China Academy of Mechanical Science Printed by the China Academy of Mechanical Science (No. 2 Shouti South Road, Beijing Postal Code 100044) Sheet X/X K Number of words xXXXXX Book size 880×1230 Edition X in xX month, 19XX Printing in X in XX month, 19XX Number of copies 1-xXX Price XXX.XX Yuan XX-XXX Mechanical Industry Standard Service Network: http://www.JB.ac.cn6 Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.