title>HG/T 3323-1982 Rubber viscosity determination method (rotational viscometer method) - HG/T 3323-1982 - Chinese standardNet - bzxz.net
Home > HG > HG/T 3323-1982 Rubber viscosity determination method (rotational viscometer method)
HG/T 3323-1982 Rubber viscosity determination method (rotational viscometer method)

Basic Information

Standard ID: HG/T 3323-1982

Standard Name: Rubber viscosity determination method (rotational viscometer method)

Chinese Name: 橡胶粘度测定方法(旋转粘度计法)

Standard category:Chemical industry standards (HG)

state:Abolished

Date of Expiration:2008-07-01

standard classification number

Standard Classification Number:Chemicals>>Rubber Products and Auxiliary Materials>>G40 Rubber Products General

associated standards

alternative situation:Replaced the original standard number HG 4-1470-1982; replaced by HG/T 3323-2008

Procurement status:Non-equivalent ISO 1652-1974

Publication information

other information

Introduction to standards:

Original standard number HG 4-1470-1982 HG/T 3323-1982 Rubber viscosity determination method (rotational viscometer method) HG/T3323-1982 Standard download decompression password: www.bzxz.net

Some standard content:

Ministry of Chemical Industry of the People's Republic of China Standard HG 4-1470-82
Adjusted to: Heh 3323-1f8 2
Method for determination of viscosity of rubber slurry
(Rotational viscometer method)
Published on February 23, 1982
Implemented on December 1, 1982
Approved by Ministry of Chemical Industry of the People's Republic of China Ministry of Chemical Industry of the People's Republic of ChinaWww.bzxZ.net
Determination of viscosity of rubber slurry
Rotational viscometer
HG4-1470--B2
Published by Technical Standards Press
(Sanlihe, Beijing)
Printed by the printing workshop of Technical Standards Press
Distributed by Beijing Publishing House of Xinhua Bookstore Sold by Xinhua Bookstores in various places Format 880×1230 1/16 Sheet 174 Words 4,00 First edition March 1983 First printing March 1983 Print run 1-6,000
Book number: 151692-4878 Price -0.07 yuan Scope of application
Ministry of Chemical Industry of the People's Republic of China Standard Method for determination of viscosity of rubber paste
(rotational viscometer method)
HG 4--1470--82
Change to HG/T 3 323 -1981
This standard applies to the determination of absolute viscosity of butyl rubber paste. 2 Definition
Viscosity is the internal friction of a fluid, which is the resistance of a layer of fluid to relative motion with another fluid, expressed in eP. 3 Instruments and equipment
3.1 Rotational viscometer: The measurement error is less than =0.5%. Step motor
Scale reading pad
Measured liquid
Structure diagram of rotational viscometer
Super constant temperature bath: temperature fluctuation range is ±0.5℃. 3.2
3.3 Thermometer: Graduation 0.1℃.
Container: 6-7cm diameter, container with a height of not less than 11cm or a stopwatch attached to the rotational viscometer. 3.5
Stopwatch: Accuracy 0.25
Sample requirements
4.1 Uniform and free of bubbles.
4.2 Sufficient number,
5 Test steps
5.1 According to the viscosity of the sample, select the appropriate rotation speed, and the continuous reading is within the range of 0% to 85% of the dial. Ministry of Chemical Industry of the People's Republic of China 1982-02-23 Issued 212-01 Implementation on 19th
HG 41470--82
5.2 Dip the rotor straight into the center of the sample (avoid bringing in bubbles) so that the liquid surface reaches the liquid level mark of the rotor (if there is a protective frame, E should be installed)
5.3 Keep the sample and rotor in the test container at a constant temperature of 25+2C (if the product standard has other provisions on the test temperature, follow the provisions of the product standard) and keep the sample temperature uniform. 5.4 Read the indicated value when the rotor rotates 1+0.034min. Note: When measuring the material sample, read the reading when it rotates 2=row.031mit. Test results
Calculate according to the instrument requirements.
The test result is the average value of the two parallel test values. The test report should include:
The source, type, manufacturing date, test date of the sample, the model of the rotational viscometer used:
The registration number:
The speed used, rpm:
The temperature of the sample at the end of the test,,
Viscosity, cP
Additional instructions;
This standard was proposed by the Beijing Rubber Industry Research and Design Institute of the Ministry of Chemical Industry and is under the jurisdiction of the Beijing Rubber Industry Research and Design Institute. This standard was drafted by the Shanghai Rubber Products Research Institute. The main drafters of the standard are Yang Xiuhong and Hong Aiwei. This standard is entrusted to the Beijing Rubber Industry Research and Design Institute for interpretation. 5 No.: 15169-2-4878
Price:
70f-e y5h
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.