title>JB/T 8145.1-1995 Cables (wires) for railway rolling stock with AC rated voltage of 3kV and below Natural styrene-butadiene rubber insulated cables (wires) for railway rolling stock - JB/T 8145.1-1995 - Chinese standardNet - bzxz.net
Home > JB > JB/T 8145.1-1995 Cables (wires) for railway rolling stock with AC rated voltage of 3kV and below Natural styrene-butadiene rubber insulated cables (wires) for railway rolling stock
JB/T 8145.1-1995 Cables (wires) for railway rolling stock with AC rated voltage of 3kV and below Natural styrene-butadiene rubber insulated cables (wires) for railway rolling stock
Basic Information
Standard ID:
JB/T 8145.1-1995
Standard Name: Cables (wires) for railway rolling stock with AC rated voltage of 3kV and below Natural styrene-butadiene rubber insulated cables (wires) for railway rolling stock
This standard specifies the product varieties, technical requirements and inspection rules of natural styrene butadiene rubber insulated cables (wires) for railway locomotives. This standard applies to natural styrene butadiene rubber insulated cables (wires) for railway locomotives with AC rated voltages of 1.5kV and below. In addition to meeting the requirements of this standard, cables (wires) shall also meet the requirements of GB12528.1. JB/T 8145.1-1995 Cables (wires) for railway locomotives with AC rated voltages of 3kV and below Natural styrene butadiene rubber insulated cables (wires) for railway locomotives JB/T8145.1-1995 Standard download decompression password: www.bzxz.net
Some standard content:
UDC 621.315.2.027.5:629.4 National Standard of the People's Republic of China Adjusted to 8145.1-25 GB12528.2—90 Shanghai Institute of Technical Supervision and Information Registration No. CN91039 Cables (wires) for railway vehicles with rated voltages up to and including 3 kvNatural-styrenbutadiene.rubberInsulated cabiles (wires)for railwayvehieles of rated voltages up to and including 3 kvNatural-styrenbutadiene.rubber insulated cables (wires) for railway vehicles Issued on November 7, 1990 State Administration of Technical Supervision Implementation on August 1, 1991 National Standard of the People's Republic of China Cables (wires) for railway vehicles with rated voltages up to and including 3 kV Natural-styrenbutadiene rubber insulated cables (wires) for railway vehicles Subject content and scope of application GB12528.2—90 This standard specifies the product varieties, technical requirements and inspection rules of natural styrene-butadiene rubber insulated cables (wires) for railway vehicles. This standard applies to natural styrene butadiene insulated railway locomotive and rolling stock cables (wires) with AC rated voltage of 1.5kV and below. In addition to meeting the requirements specified in this standard, cables (wires) shall also meet the requirements of GB12528.1. 2 Usage characteristics 2.1 Rated voltage is 750V and 1.5kV. 2.2 The long-term allowable operating temperature of the cable should not exceed 70℃: 2.3 The cable can be used in places contaminated by mineral oil but not fuel oil. 2.4 The allowable bending radius during cable laying: The cable outer diameter (D) of 20mm and below should not be less than 3D; the cable outer diameter (D) of more than 20mm should not be less than 5D. 3 Model The model of copper core natural styrene butadiene rubber insulated fluorobutyl rubber sheathed railway locomotive and rolling stock cable (wire) is DCXF/2. 4 Specifications The specifications of the cable are shown in Table 1. Rated voltage, V Approved by the State Bureau of Technical Supervision on November 7, 1990 Nominal area, mm2 Structural parameter table number Implementation on August 1, 1991 5 Technical requirements GB12528.2—90 The technical requirements for cables shall comply with the requirements of Table 2 and Table 3. Table 2 DCXF/2 type 750V copper core natural styrene butadiene rubber insulation nitrile rubber sheathed rolling stock cable (wire) Conductor nominal section Conductor specification Insulation nominal thickness Sheath nominal thickness Average outer diameter Conductor nominal section Conductor nominal section Conductor specification GB12528.2-—90 Continued table, 2 Insulation Nominal thickness Nominal thickness of sheath Average outer diameter Table 3DCXF/2 type 1.5kV copper core natural styrene-butadiene rubber insulated chloroprene rubber sheathed rolling stock cable (wire) conductor specificationsWww.bzxZ.net Nominal insulation thickness Nominal sheath thickness Average outer diameter ..·.6.8 Nominal conductor section Conductor specifications The cable shall be tested as specified in Table 4. Project name Structural dimensions Conductor structure Insulation thickness Sheath thickness ·Outer diameter dimensions Electrical performance Conductor resistance test Finished cable voltage test Untreated sample voltage test Bending sample voltage test Finished cable breakdown test Untreated sample breakdown test Finished cable surface leakage and discharge test Untreated sample surface leakage and discharge test Test Finished cable moisture resistance test GB12528.2—90 Continued Table 3 Insulation nominal thickness Sheath nominal thickness Table 4 Test Technical requirements Comply with the provisions of Article 5.1 of GB12528.1 Comply with the provisions of Article 5.2 of GB12528.1 and Tables 2~3 of this standard Comply with the provisions of Article 5.3 of GB12528.1 and Tables 2~3 of this standard Comply with the provisions of GB125 28.1 Article 5.4.1 and the provisions of Tables 2 to 3 of this standard Conform to Article 5.4.1 of GB12528.1 Conform to Article 1 of Table 5 of GB12528.1 Conform to Article 2 of Table 5 of GB12528.1 Conform to Article 3 of Table 5 of GB12528.1 Conform to Article 4 of Table 5 of GB12528.1 Conform to Article 5 of Table 5 of GB12528.1 Average outer diameter Test Method GB4909 GB3048.4. GB3048.8 and GB12528.1 Appendix C GB12528.1 Appendix D GB12528.1 Appendix E Project name Insulation mechanical physical properties Tensile strength before and after aging Elongation at break before and after aging Ozone resistance test Low-temperature winding test Untreated sample low-temperature winding test| |tt||Low temperature of sample after aging in air box Winding test Low temperature tensile test Low temperature tensile test of untreated sample Low temperature of sample after aging in air box Tensile test Mechanical and physical properties of sheath Tensile strength before and after aging Elongation at break before and after aging Mineral oil resistance test Ozone resistance test Low temperature winding test Low temperature winding test of untreated sample After aging in air box Low temperature winding test of samples Low temperature tensile test Low temperature tensile test of untreated samples Low temperature tensile test of samples aged in air box Combustion test Combustion test of untreated samples GB12528.2—90 Continued Table 4 Conform to the provisions of Article 1 of Table 3 of GB12528.1 Conform to the provisions of Article 1 of Table 3 of GB12528.1 Conform to the provisions of Article 1 of Table 3 of GB12528.1 Conform to Table 3 of GB12528.1 Article 2 Comply with Article 3 of Table 3 of GB12528.1 Comply with Article 4 of Table 3 of GB12528.1 Comply with Article 1 of Table 4 of GB12528.1 Comply with Article 1 of Table 4 of GB12528.1 Comply with Article 2 of Table 4 of GB12528.1 Comply with Article 4 of Table 4 of GB12528.1 Comply with Article 6 of Table 4 of GB12528.1 Article 7 stipulates that the test method shall comply with the provisions of Article 5.4.5 of GB12528.1. GB2951.5 and GB2951.5 and GB2951.35. GB2951.12 and GB2951.13. GB2951.6 and GB2951.6 and GB2951.15 and GB12528.1 Appendix B GB2951.35 GB2951.12 GB2951.13 GB12528.1 Test specimen treated with mineral oil Burning test Printed logo abrasion test Additional instructions: GB12528.290 Continued Table 4 Conforms to Article 8.1 of GB12528.1 This standard was proposed by the Ministry of Machinery and Electronics Industry of the People's Republic of China and is under the jurisdiction of Shanghai Cable Research Institute of the Ministry of Machinery and Electronics Industry. This standard was drafted by Shanghai Cable Research Institute. The main drafters of this standard are Jimin, Sun Zhenghua, Li Xueming, Liu Suilin and Zhang Jinglin. Test method GB12528.1 Copyright reserved. No reproduction allowed Book number: 155066·1-8009 Price: Heading 162-26 Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.