This standard specifies the type, basic parameters and dimensions, technical requirements, test methods and inspection rules, as well as marking and packaging requirements of YW series sparkless three-phase asynchronous motors. This standard applies to YW series sparkless three-phase asynchronous motors with frame sizes of 80 to 315 (hereinafter referred to as motors). All series of motors derived from this series of motors can also refer to it. JB 5337-1991 Technical conditions for YW series sparkless three-phase asynchronous motors (frame sizes 80-315) JB5337-1991 Standard download decompression password: www.bzxz.net
Some standard content:
Mechanical Industry Standard of the People's Republic of China JB/T5337-1991 Technical conditions for YW series sparkless three-phase asynchronous motors (frame size 80~315) Published on June 28, 1991 Implementation on July 1, 1992 by the Ministry of Machinery and Electronics Industry of the People's Republic of China Mechanical Industry Standard of the People's Republic of China Technical conditions for YW series sparkless three-phase asynchronous motors (frame size 80~315 1 Subject content and scope of application JB/T5337—1991 This standard specifies the types, basic parameters and dimensions, technical requirements, test methods and inspection rules of YW series sparkless three-phase asynchronous motors. And requirements for marking and packaging. This standard applies to the sparkless three-phase asynchronous motors of the 80~315YW series with frame sizes (hereinafter referred to as motors). All series of motors derived from this series of motors can also be implemented as a reference. The explosion-proof performance of this series of motors complies with the provisions of GB3836.8 and is made into a sparkless type. The explosion-proof mark is nIT3. It is suitable for Zone 2 locations in factories containing explosive mixtures of flammable gases or vapors and air in temperature groups of T1~T3. 2 Reference standards GB1993 GB1032 GB10069.1 GB10069.3 GB10068.1 GB10068.2 JB/Z29 4 JB/Z346 GB2900.25 GB2900.35 Explosion-proof electrical apparatus for explosive atmospheres General requirements Explosion-proof electrical apparatus for explosive atmospheres Spark-free electrical apparatus "n" motor housing protection classification Motor cooling method Motor structure and installation type code Motor dimensions and tolerances Motors with frame size 36 to 400 and flange number FF55 to FF1080 or FT55 to FT1080 Basic technical requirements for rotating motors Basic environmental test procedures for electrical and electronic products Test methods for three-phase asynchronous motors Determination methods and limits for noise of rotating motors Noise of rotating motors Determination methods and limits Determination methods and limits of vibration of rotating electrical machines Test Db: Alternating damp heat test method Noise engineering determination method Vibration determination method Determination methods and limits of vibration of rotating electrical machines Vibration limits Test methods for inter-turn insulation of loose-embedded windings of AC low-voltage motors Inter-turn insulation test limits of loose-embedded windings of AC low-voltage motors Packaging, storage and transportation graphic symbols Electrical terms and terminology Motor Electrical terms and terminology Types, basic parameters and dimensions Explosion-proof electrical equipment for explosive atmospheres 3.1 The protection level of the main housing of the motor is IP54 or IP55, and the junction box is IP55 (see GB4942.1). 3.2 The cooling method of the motor is IC0141 (see GB1993). 3.3 The structure and installation type of the motor are IMB3, IMB5, IMB6, IMB7, IMB8, IMB35, IMV1, IMV3, IMV5IMV6, IMV15 and IMV36 (see GB997), and are manufactured in accordance with the provisions of Table 1. 3.4 The motor rating is a continuous rating based on the continuous duty system (S1). 3.5 The rated frequency of the motor is 50Hz, and the rated voltage is 220, 380, 660, 220/380, 380/660V. Approved by the Ministry of Machinery and Electronics Industry on June 28, 1991 and implemented on July 1, 1992 Frame size 80~160 180~225 250~315 The motor should be manufactured according to the following rated power JB/T5337-1991 Installation structure type and its code (IM) B3, B5, B6, B7, B8, B35, V1 , V3, V5, V6, V15, V36 B3, BS, B35, V1 B3, B35.V1 4.0, 5.5, 7.5, 11, 15, 18.5, 22, 30, 0.55, 0.75, 1.1, 1.5, 2.2, 3.0, 437, 45, 55, 75, 90, 110, 132, 160, 200kw. 3.7 The corresponding relationship between the motor frame number and the speed and power should be in accordance with the provisions of Table 2. Table Note: The numbers 1 and 2 after S, L, and M represent different powers under the same frame number and speed. 3.8 Motor dimensions and tolerances The installation dimensions and tolerances of the motor shall comply with the requirements of Tables 3 to 6, and the overall dimensions shall not be greater than those specified in Tables 3 to 6. (See Figures 1 to 4) JB/T53371991 JB/T 5337I991 There are 15 pages left to read. Do you want to continue reading? This document was shared by Qi Chi on 2011-04-18. Continue to read the full text for free Users who read this document also read these documentsJB Don't read it anymore, just download it +o people's country nee service n industry GD-GE.GE's RESRO P ruler is the largest reward package, Buy it for the heart to maintain the country's own more real aR--e 2》A ten-for-service guarantee The shaft extension key dimensions and tolerances of the motors with R and A##R shall conform to the requirements of Table 7. Table 7 Shaft extension diameter 20_. VW225 YW318 11~. .10 JB/T5337-1991 The dimensions and tolerances of the motor shaft extension key shall comply with the provisions of Table 7. Table 7 Shaft extension diameter The radial runout tolerance at half the shaft extension length shall comply with the provisions of Table 8. Table 8 >30~50 >50~80 .0.030 .0.090 Runout tolerance The radial runout tolerance of the flange stop to the motor axis and the end face runout tolerance of the flange mating surface to the motor axis shall comply with the provisions of Table 9. Stop diameter 130~230 >230~450 >450~680 The parallelism tolerance of the motor axis to the base support surface shall conform to the provisions of Table 10. 10 80~250 >250~315 The flatness tolerance of the supporting surface of the motor foot shall comply with the provisions of Table 11. The maximum size in AB or BB >100~160bZxz.net >160~250 >250~400 >400~630 >630~1000 AB is the distance between the outer edges of the motor foot (end view) BB is the distance between the outer edges of the motor foot (side view) JB/T5337-1991 The symmetry tolerance of the motor shaft extension keyway to the center line shall comply with the provisions of Table 12. 12 >10~18 >18~30 Technical requirements Flatness tolerance The motor shall comply with the requirements of this standard and be manufactured in accordance with the drawings and technical documents approved by the prescribed procedures. 4.2 The motor shall be able to operate at rated values under the following altitudes, ambient air temperatures and ambient air relative humidity conditions. Altitude shall not exceed 1000m. The maximum ambient air temperature varies with the seasons, but shall not exceed 40℃. If the motor is specified to be used at an altitude exceeding 1000m or the maximum ambient air temperature is higher or lower than 40℃, the provisions of GB755 shall be followed. The minimum ambient air temperature is -15℃. The average maximum relative humidity of the most significant month is 90%, and the average minimum temperature of the month is not higher than 25℃. The deviation of the power supply voltage and frequency from the rated value during the operation of the motor shall be in accordance with the provisions of GB755. When the voltage and frequency are rated, the guaranteed values of its efficiency and power factor shall comply with the provisions of Table 13. The power, power factor and efficiency of the motor are determined by the measured stray loss analysis method. 4.5 Under rated voltage, JB/T5337-1991 Continued Table 13 Power factor The guaranteed value of the ratio of the motor's stall torque to the rated torque shall comply with the provisions of Table 14. Table 14 Stuck torque/rated torque JB/T5337-1991 Continued Table 14 Stuck torque/rated torque Under rated voltage, the guaranteed value of the ratio of the minimum torque to the rated torque during the motor's starting process shall not be less than the provisions of Table 15Table 15 Minimum torque/rated torque Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.