title>JB/T 8196-1996 Residual magnetism of rolling elements in rolling bearings and its evaluation method - JB/T 8196-1996 - Chinese standardNet - bzxz.net
Home > JB > JB/T 8196-1996 Residual magnetism of rolling elements in rolling bearings and its evaluation method
JB/T 8196-1996 Residual magnetism of rolling elements in rolling bearings and its evaluation method
Basic Information
Standard ID:
JB/T 8196-1996
Standard Name: Residual magnetism of rolling elements in rolling bearings and its evaluation method
This standard is formulated for the first time. This standard specifies the residual magnetism limit, measurement method and inspection rules for commercial rolling elements of rolling bearings. This standard applies to the inspection and acceptance of residual magnetism of commercial rolling elements of general-purpose rolling bearings by manufacturers and users. This standard does not apply to the rolling inspection of finished bearings after disassembly. JB/T 8196-1996 Residual magnetism of rolling elements of rolling bearings and its evaluation method JB/T8196-1996 Standard download decompression password: www.bzxz.net
Some standard content:
Machinery Industry Standard of the People's Republic of China JB/T8196—96 Rolling bearings Residual magnetism of rolling elements and its evaluation method Published on September 3, 1996 Ministry of Machinery Industry of the People's Republic of China Implementation on July 1, 1997 JB/T8196—96 This standard is formulated for the first time. This standard is proposed and managed by the National Technical Committee for Standardization of Rolling Bearings. The drafting unit of this standard: Shanghai Bearing Technology Research Institute. The drafters of this standard: Zhang Wen'an, Yan Xiali, Wang Xiajun. 1 1 Scope Machinery Industry Standard of the People's Republic of China Rolling Bearings Residual Magnetism of Rolling Elements and Its Evaluation Method This standard specifies the residual magnetism limit, measurement method and inspection rules for commercial rolling elements of rolling bearings JB/T819-96 This standard applies to the inspection and acceptance of residual magnetism of commercial rolling elements of general-purpose rolling bearings by manufacturers and users. This standard does not apply to the inspection of rolling elements after the finished bearings are disassembled. 2 Referenced Standards The provisions contained in the following standards constitute the provisions of this standard through reference in this standard. When this standard is published, the versions shown are valid. All standards are subject to revision, and parties using this standard should explore the possibility of using the latest versions of the following standards. GB308—89 GB30984 GB3102.586 GB4661—89 ZBJ1102089 JB/T539591 3 Definitions Rolling bearing steel ball Rolling bearing needle Electrical and magnetic quantities and units Rolling bearing cylindrical roller Inspection rules for rolling bearings and their commodity parts Technical conditions for residual magnetism measuring instruments for rolling bearings Residual magnetism of rolling elements: The residual magnetism of bearing rolling elements after magnetization and demagnetization. The residual magnetism of rolling elements is expressed by magnetic induction intensity according to the provisions of GB3102.5, and its unit is mT. 4 Residual magnetism value The residual magnetism limit values of various rolling elements manufactured in accordance with GB308, GB309 and GB4661 shall not exceed the provisions of Table 1, Table 2 and Table 3 respectively. Residual magnetism limit of steel ball Nominal diameter of steel ball Maximum residual magnetism mT Nominal diameter of needle roller Maximum residual magnetism mT Approved by the Ministry of Machinery Industry on September 3, 1996 Table 2 Residual magnetism limit of needle roller Implemented on July 1, 1997 Diameter of cylindrical roller Maximum residual magnetism 5 Measurement method 5.1 Measuring instrument JB/T8196—96 Table 3 Residual magnetism limit of cylindrical roller The residual magnetism value of rolling element is measured by an instrument with a range of 1mT in accordance with JB/T5395. Evaluation of residual magnetism When measuring the residual magnetism of rolling element, the maximum value measured is the residual magnetism value of the rolling element. 5.3 Measurement environment Measurement is not allowed on a magnetic workbench and in an environmental magnetic field with an intensity greater than that of the geomagnetic field. 5.4 Measurement method 5.4.1 During measurement, the measuring position of the probe on the rolling element cannot be preset, and the movement of the probe should be such that it can reach any measured part on the rolling element. 5.4.2 When measuring a steel ball, place the steel ball on the workbench, with the probe close to the surface of the steel ball, and rotate the steel ball within a workbench to measure various points of the steel ball. When measuring, it should be ensured that the measurement is made on the circumference of the cross section in different orthogonal directions, and not less than three circles. 5.4.3 When measuring needle rollers and cylindrical rollers, the rolling element to be measured can be held by hand to measure its two end faces and chamfers. 5.4.4 When the residual magnetism on the rolling element is close to the specified value, the rolling element should be placed flat first, and then placed in the east-west direction to reduce the influence of the geomagnetic field for measurement. 6 Inspection rules Residual magnetism of rolling elements shall be sampled and inspected in accordance with the provisions of ZBJ11020. The sample size shall be sampled according to the special inspection level S-4, and the qualified quality level AQL value shall be selected as 4.0. Mechanical Industry Standard Rolling Bearing Residual Magnetism of Rolling Elements and Its Evaluation Method JBT8196-96bzxz.net Published and Distributed by the China Academy of Mechanical Science Printed by the China Academy of Mechanical Science (No. 2 Shouti South Road, Beijing, Postal Code 100044)* Format 880×12301/16 Printing Sheet 1/2 Number of Words 6000First Edition in January 1997 First Printing in January 1997 Number of Prints 1-500 Price 500 Yuan 97-023 Mechanical Industry Standard Service Network: http:/kvwwJB.ac.cn969618 / Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.