Basic Information

Standard ID: HG/T 2056-1991

Standard Name: Glass-lined disc condenser

Chinese Name: 搪玻璃碟片式冷凝器

Standard category:Chemical industry standards (HG)

state:Abolished

Date of Release1991-07-06

Date of Implementation:1992-01-01

Date of Expiration:2005-06-01

standard classification number

Standard Classification Number:Chemical Industry>>Chemical Machinery and Equipment>>G94 Non-metallic Chemical Machinery and Equipment

associated standards

alternative situation:Replaced by HG/T 2056-2004

Publication information

other information

Introduction to standards:

HG/T 2056-1991 Glass-lined disc condenser HG/T2056-1991 Standard download decompression password: www.bzxz.net

Some standard content:

Chemical Industry Standard of the People's Republic of China
HG/T2056-91
Sugar Glass Disc Condenser
Published on July 6, 1991
Ministry of Chemical Industry of the People's Republic of China
Implemented on January 1, 1992
Chemical Industry Standard of the People's Republic of China
Sugar Glass Disc Condenser
Subject Content and Scope of Application
HG/T 2056
This standard specifies the type, basic parameters, main dimensions and technical requirements of the glass disc condenser. The applicable scope of the glass disc condenser is the nominal pressure inside the device is normal pressure and equal to or less than 0.25MPa, the nominal pressure inside the interlayer is equal to or less than 0.25MPa, and the temperature of the condensed medium is 0c to 200℃. 2 Reference standards
GB700 Carbon structural steel
ZBG33004 Polytetrafluoroethylene filmbZxz.net
ZBG94004 Technical conditions for glass equipment
HG/T2105 Glass equipment slip-on flange
HG/T2143 Glass equipment pipe outlet
HG/T2050 Glass equipment gasket
3 Types, basic parameters and main dimensions
3.1 Type
The disc-type condenser consists of a cover, a bottom and condensing plates. The cooling water in the interlayer is connected in series by the elbow outside the device. According to user needs, it can also be connected in parallel or in series. Figure 1 is a series type, Appendix D is a parallel type, and Appendix E is a series type. The composition of the series type disc condenser is shown in Figure 1, Table 1 and Table 2. When the cooling water temperature in the interlayer is higher than -20℃ to lower than 0℃, the material selected for the condenser pressure component should be adapted to the use temperature. Approved by the Ministry of Chemical Industry of the People's Republic of China on July 6, 1991 and implemented on January 1, 1992
HG/T205691
Figure 1 Tan Glass Disc Condenser Series Type
HG/T 2105-91
HG/T2056-91
HG/T2056-91
HG/T2056-91
GB6170—86
HG/T2056-91
Appendix B
Appendix C
Appendix A
Appendix C
Appendix C
Nominal diameter
3 .2 Basic parameters
HG/T2056—91
Loop flange
Condensation plate
Connection group
Sealing circle
Stud
Flange cover
Details
Orifice table
Hot fluid feed port
Hot fluid discharge port
Cooling water outlet
Cooling water inlet
Q235 -A
Q235-A or 10
Cloth-reinforced pressure hose
Assembly
Assembly
Q235-A
Assembly
According to the regulations
Tang glass
Tang glass
Loop-type flange PN0.6MPa
According to HG5010-58PN0.6MPa||tt ||3.2.1 Nominal pressure
The nominal pressure inside the disc condenser is divided into two types: normal pressure and 0.25MPa. When the outlet of the medium inside the condenser is connected to the atmosphere or to a storage tank connected to the atmosphere, the normal pressure level can be used, otherwise the 0.25MPa level should be used. The nominal pressure inside the interlayer is 0.25MPa.
3.2.2 Condensation area
The disc condenser consists of a cover, a bottom and condensing plates. The condensing area is the sum of the three. The cover and the bottom have the same specifications and sizes. The condensing area is half of the condensing plate of the same specifications. The condensing plates are divided into three specifications: 0.5m2/piece, 1.0m2/piece, and 2.0m2/piece, respectively represented by P0.5, P1, and P2, see Table 3.3.3 Main dimensions
Series type disc condenser main dimensions and specifications are shown in Table 3. Category
Number of condensing plates
Condensing area m2||tt| |HG/T2056—91
Reference weight kg
3.4 ​​Marking
Marking example:
HG/T2056-
Total condensing area, m2
Single condensing area, m2
Numerator represents the nominal pressure in the device MPa, which is 0 at normal pressure. Denominator represents the nominal pressure in the interlayer MPa
Glass disc condenser, the device is at normal pressure, and the interlayer is 0 .25MPa, single-piece condensing area 1m2, total condensing area 10m2.
Mark: Tang glass disc condenser
4 Technical requirements
P1×10HG/T2056-91
4.1 The material selection, manufacturing, inspection and acceptance of the disc condenser shall be in accordance with ZBG94004. 4.2 The water pressure test pressure of the interlayer between the cover and the bottom of the condenser and the interlayer of each single piece is 0.35MPa, and must be Then conduct the overall water pressure test inside the device. When the nominal pressure inside the device is normal pressure, conduct a 0.1MPa water pressure test. When the nominal pressure inside the device is 0.25MPa, conduct a 0.35MPa water pressure test. There should be no leakage at the inter-plate sealing ring. 4.3 The technical requirements for the inter-plate sealing ring and the condenser slip-on flange shall be in accordance with Appendix A and Appendix B. 4.4 When tightening the studs and nuts, they must be tightened evenly in sequence along the diagonal line, and no skewing is allowed. Strictly prevent uneven tightness from causing poor sealing or damage to the glass layer.
5 Two disc-type condenser elements with pressure levels marked with
shall not be mixed. 4.5
4.6 The thickness of the glass layer of the disc-type condenser is 0.8~1.5mm. 5. Labels, factory documents, packaging and transportation
Lawyers, factory documents, packaging and transportation According to Article 6 of ZBG94004, the label should be installed in a conspicuous position on the cover. The condenser plate, the bottom and the conspicuous part of the cover of the condenser should be stamped with a steel mark. The marking content is 5.3
HG/T2056-91
Appendix A
Seal ring of sugar glass disc condenser
(supplement)
: See Figure A1 and Table A1, Table A2 for the structure and dimensions of the seal ring.A1
Table A1 Dimension Table
Technical Requirements||t t||Standard No.
ZBG33004
Details
Outer bushing
Inner gasket
Polytetrafluoroethylene
Nitrile rubber
Q235-AF
HG/T2056-91
A2.1 The inner gasket is made of chloroprene rubber, with a Shore A hardness of 60 to 70A2.2 The outer bushing is made of polytetrafluoroethylene, and the material is in accordance with the relevant provisions of ZBG33004, with uniform thickness and an allowable deviation of ±0.1mm. The sealing surface is not allowed to have cracks and radial grooves. Appendix B
Sugar glass disc Plate condenser slip-on flange
(supplement)
B1 The structure and dimensions of the slip-on flange are shown in Figure B1 and Table B11×45°
2×45°
Table B1 Dimension table
Nominal pressure inside the vessel Normal pressure
Quantity n
B2 Technical requirements
B2.1 The material of the slip-on flange is Q235-A, which shall comply with the relevant provisions of GB700, d
2×45°
Nominal pressure inside the vessel 0.25MPa
Quantity n
B2.2 The flange shall be normalized||t t||B2.3 The flange sealing surface and surface shall not have cracks or other defects that reduce the flange strength or connection reliability. 24
The allowable deviation of the center circle diameter of the bolt hole on the flange and the chord length of two adjacent bolt holes is ±0.6mm, and the allowable deviation of the chord length of any two bolt holes is ±1.5mm.
HG/T2056-91
Appendix C
Glass disc type condenser cover, bottom, condenser plate (supplement)
C1 The structure and dimensions of the condenser cover, condenser plate and condenser bottom are shown in Figure C1, Figure C2, Figure C3 and Table C1.dz
Personal management shop
Surface glass
Figure C1 Cover
Surface glass
Surface sugar glass
Condenser
Surface sugar glass
Figure C3 Bottom
D1 Structure, pipe opening orientation see Figure D1
HG/T2056
Dimension table
Appendix D
Plate glass disc condenser parallel type
(supplement)
Take over bb
Cooling water inlet
Exhaust port| |tt||HG/T2056-91
Hot fluid inlet
Drain
Hot fluid outlet
Cooling water outlet
E1 Structure and nozzle orientation see Figure E1
Cooling water outlet
Cooling water inlet
HG/T2056-
Appendix E
Glass disc condenser
Hybrid type
(reference)
Hot fluid inlet
Exhaust
Drain
Hot fluid outlet
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.