title>JB/T 10442.3-2004 Diamond-grid coated insulating paper for electrical use Part 3: Single material diamond-grid epoxy adhesive insulating paper - JB/T 10442.3-2004 - Chinese standardNet - bzxz.net
Home > JB > JB/T 10442.3-2004 Diamond-grid coated insulating paper for electrical use Part 3: Single material diamond-grid epoxy adhesive insulating paper
JB/T 10442.3-2004 Diamond-grid coated insulating paper for electrical use Part 3: Single material diamond-grid epoxy adhesive insulating paper
Basic Information
Standard ID:
JB/T 10442.3-2004
Standard Name: Diamond-grid coated insulating paper for electrical use Part 3: Single material diamond-grid epoxy adhesive insulating paper
This part specifies the product code, performance requirements, inspection rules, test methods, packaging, marking, transportation and storage of diamond-shaped glue-coated insulating paper for electrical use. This part applies to diamond-shaped glue-coated insulating paper for electrical use. JB/T 10442.3-2004 Diamond-shaped glue-coated insulating paper for electrical use Part 3: Single material diamond-shaped epoxy glue insulating paper JB/T10442.3-2004 Standard download decompression password: www.bzxz.net
Some standard content:
ICS29.035.99 Machinery Industry Standard of the People's Republic of China JB/T10442.3--2004 Electrical rhombic coated insulating paper Part 3: Individual materials Insulating paper coaded with epoxy resin binder forming rhombic patternforelectricalpurposes Part3:Individual materials Insulating paper coaded with epoxy resin binder forming rhombic pattern2004-02-10 Issued 2004-06-01 Implementation The National Development and Reform Commission of the People's Republic of China Issued Foreword 2 Normative reference documents, 3 Product code, specification. 3.1 Code 3.2 Specification, 4 Requirements Performance requirements 5 Product curing conditions Product batch, sampling rules and factory test items6 Test method 7.1 Appearance..| |tt||7.2 Dimensions, 7.3 Performance requirements 8 Packaging, marking, storage and transportation Storage period, Table 1 Performance requirements JB/r10442.3—2004 JB/T10442.3—2004 JB/10442 "Electrical diamond coated insulating paper" is divided into three parts: - Part 1: Definition and general requirements: - Part 2: Test methods: - Part 3: Single material diamond epoxy adhesive insulating paper. This part is the third part of JB Hall 10442. This part is formulated for the first time. This part is proposed by the China Machinery Industry Federation. This part is under the jurisdiction of the National Technical Committee for Standardization of Insulating Materials. This part was drafted by Guilin Electric Science Research Institute, Nantong Hongan Sanmu Insulation Material Co., Ltd., Leshan Ouda Insulation Material Co., Ltd., and Shenyang Transformer Co., Ltd. The main drafters of this part are Li Bingsong, Jian Xuemei, Chen Kuan, Yang Heping, Lei Qiang, and Xiao Fuming. 1 Scope Electrical diamond coated insulating paper Part 3: Single material Diamond epoxy adhesive insulating paper JB/T10442.3--2004 This part of JB/T10442 specifies the product code, performance requirements, inspection rules, test methods, packaging, marking, transportation and storage of diamond epoxy adhesive insulating paper for electrical use. This part is used for diamond epoxy adhesive insulating paper. The product is made by coating the modified epoxy resin on the insulating paper in a diamond shape and curing it into the B stage. It can be used for turn-to-turn and inter-layer insulation of transformers and mutual inductors. 2 Normative references The clauses in the following documents become the clauses of this part through reference in this part of JB/T10442. For any dated referenced document, all subsequent amendments (excluding errata) or revisions are not applicable to this part. However, parties to an agreement based on this part are encouraged to study whether the latest versions of these documents can be used. For any undated referenced document, the latest version applies to this part. JB/T10442.1 Diamond-grid coated insulating paper for electrical use Part 1: Definitions and general requirements JB/10442.2 Diamond-grid coated insulating paper for electrical use Part 2: Test methods 3 Product code and specification 3.1 Code 72EP9.4/6.5·αd-××α can be 45°, 20° or other angles. 3.2 Specifications Divided by substrate thickness. The following specifications are recommended: 0.08mm, 0.13mm, 0.18mm, 0.20mm, 0.25mm. 4 Requirements 4.1 Appearance Should meet the requirements of JB/10442.1. 4.2 Size Width: Recommended to use 600mm±10mm: 800mm±15mm: 1000mm±20mm. Length: The diameter of the roll is 300mm to 360mm or as stipulated in the contract between the supplier and the buyer. Each roll shall not exceed four sections, and the length of each section shall not be less than 5m, and there shall be obvious markings at the head of the section. Diameter of the inner core of the roll: 76mm±2mm. 4.3 Performance requirements Should meet the requirements of Table 1. JB/T10442.3—2004 Thickness and tolerance of substrate Fitness of substrate Thickness of single-sided adhesive Electrical conductivity of water extract pH value of water extract Oil absorption 100℃±2 Pollution to transformer oil Elongation 5Product curing conditions In air N/10mm width 1Performance requirements 0.080±0.005 ≥450 ≥500 0.130±0.007 0.180±0.0100 .200±0.010 ≥650 ≥400 No pollution (tan8<0.001) ≥900 ≥1000 ≥160 ≥1350 ≥1500 ≥180Www.bzxZ.net ≥1500 ≥1700 0.250±0.0t0 ≥230 ≥100 ≥2000 ≥2300 Firstly cure at 90℃±5℃ for 3h, then cure at 125℃±5℃ for 6h, or according to the curing conditions specified by the supplier and the tape supplier. 6 Product batch, sampling rules and factory test items The products are produced in batches of 2 tons continuously. For each batch, three rolls are randomly selected and the full width and length are several meters. The sample is cut from one sample and the other two samples are reserved. Each batch should be tested for factory delivery. The items are appearance, number of sections and items 1, 3, 11, 12, 13, 14 (in air) in Table 1. 7 Test method 7.1 Appearance Perform according to JB/T10442.2. 7.2 Size The outer diameter of the coil, the inner diameter of the core and the length of each section are measured with a steel ruler. Performance requirements According to the provisions of JB/10442.2, see Table 1. 2 Packaging, marking, storage and transportation Should comply with the requirements of JB/T10442.1 Storage period The storage period of the product is 12 months under room temperature conditions. JB/T10442.3—2004 People's Republic of China Mechanical Industry Standard Electrical diamond coated insulating paper Part 3: Single material diamond epoxy adhesive insulating paper JB/T10442.3-2004 Published and distributed by Machinery Industry Press No. 22, Baiwanzhuang Street, Beijing Postal Code: 100037 Format 890mm×1240mm1/1 6?0.5 printing sheets·11,000 words 1st edition, 1st printing, June 2004 Book number: 15111·7302 Website: http://cmpbook.comEditorial department phone: (010)88379779 Direct sales center phone: (010)88379693 All books without anti-counterfeiting label on the cover are pirated Copyright reserved Infringements will be investigated Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.