Basic Information

Standard ID: JB/T 6538-1992

Standard Name: Reciprocating booster pump

Chinese Name: 往复式增压泵

Standard category:Machinery Industry Standard (JB)

state:Abolished

Date of Release1992-12-25

Date of Implementation:1993-07-01

Date of Expiration:2008-12-01

standard classification number

Standard Classification Number:Machinery>>General Machinery and Equipment>>J71 Pump

associated standards

alternative situation:Replaced by JB/T 6538-2008

Publication information

other information

Focal point unit:Hefei General Machinery Research Institute

Publishing department:Hefei General Machinery Research Institute

Introduction to standards:

This standard specifies the types and basic parameters, technical requirements, test methods, marking, packaging and storage of reciprocating booster pumps. This standard applies to reciprocating booster pumps that transport oilfield sewage or clean water with a temperature not higher than 95°C, a total mineralization not greater than 30,000 mg/L, a mechanical impurity content not greater than 30 mg/L, and a solid particle size not greater than 15 μm. The rated discharge pressure of the pump is not higher than 50 MPa, the inlet pressure is not lower than 3 MPa, the boost range is 4~20 MPa, and the rated flow rate is 2~80 m3/h. JB/T 6538-1992 Reciprocating Booster Pump JB/T6538-1992 Standard download decompression password: www.bzxz.net

Some standard content:

Mechanical Industry Standard of the People's Republic of China
JB/T6538-92
Reciprocating Booster Pump
Published on 1992-12-25
Implementation on 1993-07-01 by the Ministry of Machinery and Electronics Industry of the People's Republic of China
Mechanical Industry Standard of the People's Republic of China
Reciprocating Booster Pump
JB/T6538-92
Published and issued by the Machinery Standardization Research Institute of the Ministry of Machinery and Electronics Industry Printed by the Machinery Standardization Research Institute of the Ministry of Machinery and Electronics Industry (P.O. Box 8144, Beijing
Postal Code 100081)
Copyright
No Reprint
Number of copies 20,000
Format 880×12301/16 Print quantity
First printing in May 1993
First edition in May 1993
Print number 00,001-500
Price 2.80 yuan
No. 1000
Mechanical Industry Standard of the People's Republic of China
Reciprocating Booster Pump
1. Subject content and scope of application
JB/T653892
This standard specifies the types and basic parameters, technical requirements, test methods, marking, packaging and storage of reciprocating booster pumps. This standard applies to reciprocating booster pumps (hereinafter referred to as pumps) that deliver oily wastewater or clean water with a temperature not higher than 95°C, a total mineralization not greater than 30,000 mg/L, a mechanical impurity content not greater than 30 mg/L, and a solid particle size not greater than 15 μm. The rated discharge pressure of the pump is not higher than 50 MPa, the inlet pressure is not lower than 3 MPa, the boost range is 4 to 20 MPa, and the rated flow rate is 2 to 80 m/h. 2
Cited standards
GB1032
GB1184
GB7784
GB9112
GB9234
GB11473
GB/T13306
GB/T13384
ZBJ71018
Pump type
Differential horizontal type;
Small and medium-sized three-phase Asynchronous motor test method
Shape and position tolerance Provisions for unmarked tolerances Test method for motorized reciprocating pumps
Steel pipe type
Technical conditions for motorized reciprocating tickets
Model compilation method for reciprocating pumps
General technical conditions for packaging of electromechanical products
Hydraulic pressure and leakage test for parts and components of reciprocating pumps Opposed balanced type
3.2.Model compilation
Model compilation of pumps shall comply with the provisions of GB11473. 4
Basic parameters
Basic parameters of pumps shall comply with the provisions of Table 1. Table 1
Rated discharge pressure
Approved by the Ministry of Machinery and Electronics Industry on December 25, 1992 2.50
Constant flow
Implemented on July 1, 1993
Rated discharge pressure
The plunger diameter of the pump shall be selected from Table 2.
Series
Series
Note: Series 1 is preferred.
Technical requirements
JB/T6538-92
Continued Table 1
The pump shall comply with the requirements of this standard and be manufactured according to the drawings and technical documents approved by the prescribed procedures. When there are special requirements for the pump, it can be manufactured according to the agreement. 90
The pump shall meet the continuous working system under the rated working conditions (the continuous working system means that the pump can run continuously for 8 to 24 hours a day under the rated working conditions). The pump shall be able to operate safely at the opening pressure of the safety valve and the rated speed. The pump shall meet the following conditions when operating:
The leakage of the stuffing box shall not exceed 0.01% of the rated flow of the pump. When the rated flow rate of the pump is less than 10m*/h, the leakage of the stuffing box should not exceed 1L/h;
The static sealing surfaces should not leak;wwW.bzxz.Net
The lubricating oil pressure and oil level are within the specified range, and the oil temperature in the transmission box should not exceed 95C; there is no abnormal sound and vibration;
The prime mover should not be overloaded under the rated working condition of the pump. The performance indicators of the pump under the rated working condition should meet the requirements of Table 3. Table 3
Flow rate m/h
Efficiency of the pump %
Volume coefficient %
Rated discharge pressure
(95~110)%Q
The specific weight of the pump (the ratio of the pump weight to the rated input power) should not be greater than 50kg/kW. The noise sound pressure level during operation shall comply with the provisions of Table 4, Rated input power
>37~75
>75~300
JB/T 653892
Rated discharge pressure MPe
5.9 Under the condition of complying with the operating rules, the cumulative operating life of the pump from the time it is put into operation to the first overhaul (wearing parts can be replaced) shall not be less than 12000h.
The inlet and outlet flanges of the pump shall comply with the provisions of GB9112. 5.10
The pump inlet shall be equipped with a pressure protection device; the outlet shall be equipped with a safety valve or overflow valve (or other types of overpressure protection devices). The opening pressure of the safety valve shall be adjusted to 1.05~1.25 times the rated discharge pressure, and its discharge pressure shall not be greater than 1.1 times the opening pressure. 5.12
The leaked liquid (or flushing liquid) of the stuffing box shall be collected and discharged centrally. The liquid or leakage test of the parts and components of the pump that bear the pressure should comply with the provisions of ZBJ71018 and be marked. The assembly torque should be specified for the important bolt and nut connections such as the connection between the cylinder body and the power end, the connection between the gland and the cylinder body. The coupling, transmission belt and other moving parts that may cause harm to the human body should have protective covers. The pump should have special tools for lifting and assembly and disassembly during installation and maintenance. The replacement period of the main wearing parts of the pump should not be less than the provisions of Table 5. Table 5
Name of wearing parts
Oilfield sewage
Oilfield sewage
Oilfield sewage, clean water
Rated discharge pressure MPa
Failure-free operation time
3000 (6 repairs allowed)
The materials of the main parts of the pump should have a certificate of conformity. The materials of the crankshaft, connecting rod, crosshead and cylinder body should be tested for mechanical properties, and the chemical composition analysis of stainless steel materials should be conducted.
Sand, scale, gate, riser, burr, etc. on the casting surface should be removed. Stress relief treatment should be applied to the casting. The thread accuracy of connecting rod bolts or nuts, and high-pressure side bolts or nuts on the cylinder should not be less than 6g/6H; the screw-in depth of the stud should not be less than 1.25 times the major diameter of the thread.
5.21 When using materials that are easy to scratch or bite to make nuts or stuffing boxes and stuffing glands, the hardness difference between the two should not be less than 5HRC or other better methods should be adopted. When assembling, the threads should be coated with grease to prevent the threads from scratching and biting. 5.22
The friction surface and sealing surface of the pump parts should not have defects such as pores, looseness, bumps, scratches, etc. The main parts of the pump should not be less than the 8th grade accuracy specified in GB1184, and should meet the requirements of the Taiwan drawings. The crankshaft, connecting rod bolts and other high-strength bolts should be inspected, and the variable section of the crankshaft, connecting rod, connecting rod bolts and plunger should have a rounded corner and smooth transition. The surface roughness of the machined surface of the main parts of the pump shall comply with the provisions of Table 6. 5.27
Part name
Transmission housing
Crosshead pin
+ prefix
Filling bevel box
JB/T6538-92
Machinery surface name
Crosshead guide hole
Main shaft journal
Crank neck
Crank neck medical angle
Friction surface with bushing
Friction surface of outer ring
Friction surface of outer circle
Seal surface
Seal surface
Surface roughness R.
Before assembly, the parts should be cleaned; after assembly, the exposed non-machined surface should be coated with anti-rust primer and then anti-rust paint. When the pump is inspected for cleanliness, its indicators should comply with the provisions of Table. Table?
Total volume of measured parts
>0.005~0.01
>0.01~0.02
>0. 02~0. 05
>0.05~0.1
>0.1~0.2
The pump supplied as a complete set includes:
1 complete pump;
1 prime mover;
Residue weight
Consumable parts and spare parts are not less than 1/2 set;
1 set of special tools;
Accompanying documents.
Total volume of measured parts
>10~20
Residue weight
Above supply scope and quantity shall be subject to the provisions of the agreement if there is any increase or decrease. Under the condition that the user complies with the provisions of the product manual, the auxiliary manufacturer shall guarantee the pump for 1a within 18 months from the date of shipment. During the warranty period of 5.30
, if the product is damaged or cannot work normally due to poor manufacturing quality, the manufacturer shall be responsible for free repair or replacement of parts (excluding consumable parts).
Test method
General requirements
The joints of the inlet and discharge pipes should not leak, and a filter screen should be installed at the inlet end. 6.1.1
6.1.2-The pressure allowed by the inlet and discharge pipes should be adapted to the maximum suction pressure and maximum discharge pressure of the pump under test respectively. 6.1.3 The test medium is clean water at 5-60℃. If there are special requirements for the physical properties of the test medium, a separate agreement can be made. 6.1.4 The principle of the test device is shown in Appendix A (reference). 6.2 Working conditions and only instruments and meters.
JB/T 6538-92
The test should be carried out on a device that meets the requirements of Article 6.1.4. The test shall be carried out under rated working conditions, and the allowable deviation of the measured values ​​of the test working condition parameters relative to the rated values ​​shall comply with the provisions of Table 8. Table 8
Rated working condition parameters
Discharge pressure of the ticket
Inlet pressure of the pump
Accumulated pressure or speed
When the test working condition deviates from the rated working condition, it shall be converted according to the provisions. The allowable fluctuation range of the indication value of the measuring instrument and meter shall comply with the provisions of Table 9. Table 9
Calcium content parameters
Pump speed and maximum speed
Allowable fluctuation range
Measurement parameters
Allowable deviation value of the value
Not less than the rated value
Rated value ±5%
Allowable fluctuation range
Pump input power
Prime motor input power
During the test, after confirming that the pump operation has reached a stable working condition, all instrument readings shall be read and recorded at the same time. The number of measurements for each measured parameter shall be 3 times, and the arithmetic mean shall be taken as the measured value. The accuracy of the test instruments and meters shall comply with the provisions of Table 10. All measuring instruments and meters shall be within the effective use period and have a calibration certificate issued by the measurement department or relevant departments. Table 10 Measurement items Input power Speed ​​or rotation speed 6.3 Test requirements Only instruments and meters shall be corrected Type and sample inspection Factory inspection Test run, load endurance test, continuous operation test, performance test, safety valve (relief valve) test, explosion test, cleanliness inspection shall comply with the provisions of GB7784. Determination of the noise measurement point See Appendix B (reference).
Parameter measurement and data processing
The measurement and data processing of flow, pressure, temperature, speed and power shall comply with the provisions of GB7T84. Drawing of performance curve
The relationship curve between flow, power, pump efficiency and pressure difference at rated pump speed is shown in Figure 1. Test report
The content of type inspection report includes:
JB/T 653892
Efficiency,
Information on pump assembly and inspection of main parts before test: flow Q
Power P
Pressure difference pMPa
Information on pump disassembly inspection results and changes in the size of main friction pairs after test; test records, pump performance curve:
Conclusion of pump test;
Test device system diagram;
Information on test medium;
Calibration record of test instruments and meters. The contents of the sampling inspection report include:
Test records, pump performance curve;
Test conclusion.
The contents of the factory inspection report include:
Test records;
Test conclusion.
The test data shall be signed by the person in charge of the test. Inspection rules
General requirements
Each pump shall be inspected and qualified by the technical inspection department and accompanied by a product certificate before it can be shipped. The pump can only be put into trial operation after the main parts material, manufacturing accuracy, assembly accuracy inspection and hydraulic test are qualified. Various types of pump inspections shall be carried out according to the items specified in Table 11. Table 11
Test items
Trial operation
Load operation test
Continuous operation test
Performance test
Test items
Rated working condition performance inspection
Safety valve, relief valve test
Noise test
JB/T653892
Continued Table 11
Note: V-indicates that the test is to be carried out, and × indicates that the test is not to be carried out. 7.1.4 Under special circumstances, with the user's consent, the factory inspection allows the pump to be tested under deceleration or reduced pressure or on-site. 7.2 Type inspection
7.2.1 The first prototype of a new product shall be subjected to type inspection. For a new product series, only the basic prototype of the series shall be subjected to type inspection. After passing the inspection, the prototype of a new product with lower power, lower discharge pressure and smaller boost range than the prototype may not be subjected to type inspection. 7.2.3 Products transferred from other factories shall be subject to type inspection. 7.2.4 Products shall be subject to type inspection when there are major changes in design, process and materials. 7.3 Sampling inspection
Pumps produced in batches shall be subject to sampling inspection. The inspection plan shall be the single sampling plan specified in Table 12. The sampling time shall be evenly distributed in 1a.
Batch range
51--90
91~150
7.4 Factory inspection
7.4.1 Each pump shall be subject to factory inspection.
Sample size n
Qualified judgment number Ac
Unqualified judgment number Re
7.4.2 During factory inspection, the various indicators of the pump shall comply with the provisions of Articles 5.5, 5.6 and 5.11. If all the indicators of the pump meet the above provisions, it is a qualified product. If one of the indicators in the above provisions is not met, it is a non-conforming product. 8
Marking, packaging and storage
The nameplate of the pump should be fixed on a conspicuous part of the pump, and the size and technical requirements of the nameplate should comply with the provisions of GB/T13306. The nameplate should include the following contents:
Manufacturer name;
Pump model and name;
Main technical specifications: rated flow, m/h; rated discharge pressure, MPa; rated boost pressure, MPa; pump speed, min-1: prime mover c.
Power, kW; weight, kg;
Factory number;
Year and month of production.
The pump should be marked with the registered trademark.
Important externally purchased supporting equipment of the pump should also have a nameplate. The transmission housing of the pump should have an indication of the direction of rotation of the crankshaft. Other important equipment that is only allowed to rotate in one direction should have an indication of the direction of rotation. The pump should be treated with rust prevention or paint. All passages to the atmosphere should be sealed. Flanges and welding grooves should be covered, and auxiliary pipelines with smaller diameters should be removed or temporarily supported.
8.6 The accompanying documents of the pump should include installation drawings, drawings of wearing parts, product instructions, packing lists, and product certificates. The documents should be wrapped in watertight plastic bags and placed in the packaging box.
JB/T6538-92
The packaging of the pump should comply with the provisions of GB/T13384 and should be closed. 8.7
Under normal storage conditions, the manufacturer should ensure that the pump will not rust within six months from the date of shipment. Metering device
Supplementary pump
IB/T6538-92
Attachment A
System diagram of reciprocating booster pump test device
(reference)
Hongquan Road
Pressure slurry
Tested pump
Figure A1 Open test system
Heat exchanger
Shuliutao
Figure A2 Closed test system
Pressure2- The pressure allowed to be borne by the inlet and discharge pipelines shall be adapted to the maximum suction pressure and maximum discharge pressure of the tested pump respectively. 6.1.3 The test medium is clean water at 5-60℃. If there are special requirements for the physical properties of the test medium, a separate agreement can be made. 6.1.4 The principle of the test device is shown in Appendix A (reference). 6.2 Working conditions and instruments and meters.
JB/T 6538-92
The test shall be carried out on a device that meets the requirements of Article 6.1.4. The test shall be carried out under rated working conditions, and the allowable deviation of the measured values ​​of the test working condition parameters relative to the rated values ​​shall comply with the regulations in Table 8 Table 8
Rated working condition parameters
Discharge pressure of the ticket
Inlet pressure of the pump
Accumulated cover or speed
When the test working condition deviates from the rated working condition, it shall be converted according to the regulations. The allowable fluctuation range of the indication value of the measuring instrument and meter shall comply with the regulations in Table 9. Table 9
Calcium content parameters
Maximum pump speed
Allowable fluctuation range
Measurement parameters
Allowable deviation of the value
Not less than the rated value
±5% of the rated value
Allowable fluctuation range
Pump input power
Prime motor input power
During the test, after confirming that the pump operation has reached a stable working condition, all instrument readings should be read and recorded at the same time. The number of measurements for each measured parameter should be 3 times, and the arithmetic mean value should be taken as the measured value. The accuracy of the test instruments and meters should comply with the provisions of Table 10. All measuring instruments and meters should be within the effective use period and have a calibration certificate issued by the metrology 6.2.6
department or relevant departments. Table 10
Measurement items
Input power
Velocity or speed
6.3 Test requirements
Only for instruments and equipment
Type and sample inspection
Factory inspection
Trial operation, load endurance operation test, continuous operation test, performance test, safety valve (relief valve) test, explosion test, cleanliness inspection shall comply with the provisions of GB7784.
Determination of the noise measurement point
See Appendix B (reference).
Parameter measurement and data processing
The measurement and data processing of flow, pressure, temperature, speed and power shall comply with the provisions of GB7T84. Drawing of performance curve
Draw the relationship curve between flow, power, pump efficiency and pressure difference at rated pump speed as shown in Figure 1. Test report
Type inspection report includes:
JB/T 653892
Efficiency,
Information on pump assembly and inspection of main parts before test: Flow Q
Power P
Pressure difference pMPa
Information on pump disassembly inspection results and changes in the dimensions of main friction pairs after test; Test record, pump performance curve:
Conclusion of pump test;
Test device system diagram;
Information on test medium;
Calibration record of test instruments and meters. Sampling inspection report includes:
Test record, pump performance curve;
Test conclusion.
Factory inspection report includes:
Test record;
Test conclusion.
Test data should be signed by the person in charge of the test. Inspection rules
General requirements
Each pump shall be inspected and qualified by the technical inspection department and accompanied by a product certificate before it can be shipped. The pump can only be tested after the main parts material, manufacturing accuracy, assembly accuracy inspection and hydraulic test are qualified. Various types of pump inspections shall be carried out according to the items specified in Table 11. Table 11
Test items
Test operation
Load operation test
Continuous operation test
Performance test
Test items
Rated working condition performance inspection
Safety valve, overflow valve test
Noise test
JB/T653892
Continued Table 11
Note: V-indicates testing, × indicates no testing. 7.1.4 In special cases, with the consent of the user, the factory inspection allows the pump to be tested under deceleration or reduced pressure or on-site. 7.2 Type inspection
7.2.1 The first prototype of a new product shall be subject to type inspection. For a new product in a series, only the basic prototype of the series shall be subject to type inspection. After passing the inspection, the prototype of a new product with lower power, lower discharge pressure and smaller boost range than the prototype may not be subject to type inspection. 7.2.3 Products transferred from other factories shall be subject to type inspection. 7.2.4 Products shall be subject to type inspection when there are major changes in design, process and materials. 7.3 Sampling inspection
Pumps produced in batches shall be subject to sampling inspection. The inspection plan shall be a single sampling plan as specified in Table 12. The sampling time shall be evenly distributed in 1a.
Batch range
51--90
91~150
7.4 Factory inspection
7.4.1 Each pump shall be subject to factory inspection.
Sample size n
Number of qualified judgments Ac
Number of unqualified judgments Re
7.4.2 During factory inspection, the various indicators of the pump shall comply with the provisions of Articles 5.5, 5.6 and 5.11. If the pump meets all the above-mentioned indicators, it is a qualified product. If one of the above-mentioned indicators is not met, it is a unqualified product. 8
Marking, packaging and storage
The nameplate of the pump shall be fixed in a conspicuous position of the pump, and the size and technical requirements of the nameplate shall comply with the provisions of GB/T13306. The nameplate shall include the following information: 8.1
Manufacturer name;
Pump model and name;
Main technical specifications: Rated flow, m/h; Rated discharge pressure, MPa; Rated boost pressure, MPa; Pump speed, min-1: Prime motor power, kW; Weight, kg;
Factory number;
Year and month of production.
The pump shall be marked with the registered trademark.
Important externally purchased supporting equipment of the pump shall also have a nameplate. The transmission housing of the pump shall have an indication of the direction of rotation of the crankshaft. Other important equipment that is only allowed to rotate in one direction shall have an indication of the direction of rotation. The pump shall be treated with rust prevention or paint. All passages to the atmosphere shall be sealed. Flanges and welding grooves should be covered, and auxiliary pipelines with smaller diameters should be removed or temporarily supported.
8.6 The accompanying documents of the pump should include installation drawings, drawings of wearing parts, product instructions, packing lists, and product certificates. The documents should be wrapped in watertight plastic bags and placed in the packaging box.
JB/T6538-92
The packaging of the pump should comply with the provisions of GB/T13384 and should be closed. 8.7
Under normal storage conditions, the manufacturer should ensure that the pump will not rust within six months from the date of shipment. Metering device
Supplementary pump
IB/T6538-92
Attachment A
System diagram of reciprocating booster pump test device
(reference)
Hongquan Road
Pressure slurry
Tested pump
Figure A1 Open test system
Heat exchanger
Shuliutao
Figure A2 Closed test system
Pressure2- The pressure allowed to be borne by the inlet and discharge pipelines shall be adapted to the maximum suction pressure and maximum discharge pressure of the tested pump respectively. 6.1.3 The test medium is clean water at 5-60℃. If there are special requirements for the physical properties of the test medium, a separate agreement can be made. 6.1.4 The principle of the test device is shown in Appendix A (reference). 6.2 Working conditions and instruments and meters.
JB/T 6538-92
The test shall be carried out on a device that meets the requirements of Article 6.1.4. The test shall be carried out under rated working conditions, and the allowable deviation of the measured values ​​of the test working condition parameters relative to the rated values ​​shall comply with the regulations in Table 8 Table 8
Rated working condition parameters
Discharge pressure of the ticket
Inlet pressure of the pump
Accumulated cover or speed
When the test working condition deviates from the rated working condition, it shall be converted according to the regulations. The allowable fluctuation range of the indication value of the measuring instrument and meter shall comply with the regulations in Table 9. Table 9
Calcium content parameters
Maximum pump speed
Allowable fluctuation range
Measurement parameters
Allowable deviation of the value
Not less than the rated value
±5% of the rated value
Allowable fluctuation range
Pump input power
Prime motor input power
During the test, after confirming that the pump operation has reached a stable working condition, all instrument readings should be read and recorded at the same time. The number of measurements for each measured parameter should be 3 times, and the arithmetic mean value should be taken as the measured value. The accuracy of the test instruments and meters should comply with the provisions of Table 10. All measuring instruments and meters should be within the effective use period and have a calibration certificate issued by the metrology 6.2.6
department or relevant departments. Table 10
Measurement items
Input power
Velocity or speed
6.3 Test requirements
Only for instruments and equipment
Type and sample inspection
Factory inspection
Test run, load endurance test, continuous operation test, performance test, safety valve (relief valve) test, explosion test, cleanliness inspection shall comply with the provisions of GB7784.
Determination of the noise measurement point
See Appendix B (reference).
Parameter measurement and data processing
The measurement and data processing of flow, pressure, temperature, speed and power shall comply with the provisions of GB7T84. Drawing of performance curve
Draw the relationship curve between flow, power, pump efficiency and pressure difference at rated pump speed as shown in Figure 1. Test report
Type inspection report includes:
JB/T 653892
Efficiency,
Information on pump assembly and inspection of main parts before test: Flow Q
Power P
Pressure difference pMPa
Information on pump disassembly inspection results and changes in the dimensions of main friction pairs after test; Test record, pump performance curve:
Conclusion of pump test;
Test device system diagram;
Information on test medium;
Calibration record of test instruments and meters. Sampling inspection report includes:
Test record, pump performance curve;
Test conclusion.
Factory inspection report includes:
Test record;
Test conclusion.
Test data should be signed by the person in charge of the test. Inspection rules
General requirements
Each pump shall be inspected and qualified by the technical inspection department and accompanied by a product certificate before it can be shipped. The pump can only be tested after the main parts material, manufacturing accuracy, assembly accuracy inspection and hydraulic test are qualified. Various types of pump inspections shall be carried out according to the items specified in Table 11. Table 11
Test items
Test run
Load operation test
Continuous operation test
Performance test
Test items
Rated working condition performance inspection
Safety valve, overflow valve test
Noise test
JB/T653892
Continued Table 11
Note: V-indicates testing, × indicates no testing. 7.1.4 In special cases, with the consent of the user, the factory inspection allows the pump to be tested under deceleration or reduced pressure or on-site. 7.2 Type inspection
7.2.1 The first prototype of a new product shall be subject to type inspection. For a new product in a series, only the basic prototype of the series shall be subject to type inspection. After passing the inspection, the prototype of a new product with lower power, lower discharge pressure and smaller boost range than the prototype may not be subject to type inspection. 7.2.3 Products transferred from other factories shall be subject to type inspection. 7.2.4 Products shall be subject to type inspection when there are major changes in design, process and materials. 7.3 Sampling inspection
Pumps produced in batches shall be subject to sampling inspection. The inspection plan shall be a single sampling plan as specified in Table 12. The sampling time shall be evenly distributed in 1a.
Batch range
51--90
91~150
7.4 Factory inspection
7.4.1 Each pump shall be subject to factory inspection.
Sample size n
Number of qualified judgments Ac
Number of unqualified judgments Re
7.4.2 During factory inspection, the various indicators of the pump shall comply with the provisions of Articles 5.5, 5.6 and 5.11. If the pump meets all the above-mentioned indicators, it is a qualified product. If one of the above-mentioned indicators is not met, it is a unqualified product. 8
Marking, packaging and storage
The nameplate of the pump shall be fixed in a conspicuous position of the pump, and the size and technical requirements of the nameplate shall comply with the provisions of GB/T13306. The nameplate shall include the following information: 8.1
Manufacturer name;
Pump model and name;
Main technical specifications: Rated flow, m/h; Rated discharge pressure, MPa; Rated boost pressure, MPa; Pump speed, min-1: Prime motor power, kW; Weight, kg;
Factory number;
Year and month of manufacture.
The pump shall be marked with the registered trademark.
Important externally purchased supporting equipment of the pump shall also have a nameplate. The transmission housing of the pump shall have an indication of the direction of rotation of the crankshaft. Other important equipment that is only allowed to rotate in one direction shall have an indication of the direction of rotation. The pump shall be treated with rust prevention or paint. All passages to the atmosphere shall be sealed. Flanges and welding grooves should be covered, and auxiliary pipelines with smaller diameters should be removed or temporarily supported.
8.6 The accompanying documents of the pump should include installation drawings, drawings of wearing parts, product instructions, packing lists, and product certificates. The documents should be wrapped in watertight plastic bags and placed in the packaging box.
JB/T6538-92
The packaging of the pump should comply with the provisions of GB/T13384 and should be closed. 8.7
Under normal storage conditions, the manufacturer should ensure that the pump will not rust within six months from the date of shipment. Metering device
Supplementary pump
IB/T6538-92
Attachment A
System diagram of reciprocating booster pump test device
(reference)
Hongquan Road
Pressure slurry
Tested pump
Figure A1 Open test system
Heat exchanger
Shuliutao
Figure A2 Closed test system
PressureAll instrument readings shall be read and recorded at the same time. Each measured parameter shall be measured three times, and the arithmetic mean shall be taken as the measured value. The accuracy of the test instruments and meters shall comply with the provisions of Table 10. All measuring instruments and meters shall be within the effective use period and have a calibration certificate issued by the measurement department or relevant departments. Table 10 Measurement items Input power Speed ​​or rotation speed 6.3 Test requirements Only instruments and meters shall be corrected Type and sample inspection Factory inspection Test run, load endurance test, continuous operation test, performance test, safety valve (relief valve) test, explosion test, cleanliness inspection shall comply with the provisions of GB7784. Determination of the noise measurement point See Appendix B (reference).
Parameter measurement and data processing
The measurement and data processing of flow, pressure, temperature, speed and power shall comply with the provisions of GB7T84. Drawing of performance curve
The relationship curve between flow, power, pump efficiency and pressure difference at rated pump speed is shown in Figure 1. Test report
The content of type inspection report includes:
JB/T 653892
Efficiency,
Information on pump assembly and inspection of main parts before test: flow Q
Power P
Pressure difference pMPa
Information on pump disassembly inspection results and changes in the size of main friction pairs after test; test records, pump performance curve:
Conclusion of pump test;
Test device system diagram;
Information on test medium;
Calibration record of test instruments and meters. The contents of the sampling inspection report include:
Test records, pump performance curve;
Test conclusion.
The contents of the factory inspection report include:
Test records;
Test conclusion.
The test data shall be signed by the person in charge of the test. Inspection rules
General requirements
Each pump shall be inspected and qualified by the technical inspection department and accompanied by a product certificate before it can be shipped. The pump can only be put into trial operation after the main parts material, manufacturing accuracy, assembly accuracy inspection and hydraulic test are qualified. Various types of pump inspections shall be carried out according to the items specified in Table 11. Table 11
Test items
Trial operation
Load operation test
Continuous operation test
Performance test
Test items
Rated working condition performance inspection
Safety valve, relief valve test
Noise test
JB/T653892
Continued Table 11
Note: V-indicates that the test is to be carried out, and × indicates that the test is not to be carried out. 7.1.4 Under special circumstances, with the user's consent, the factory inspection allows the pump to be tested under deceleration or reduced pressure or on-site. 7.2 Type inspection
7.2.1 The first prototype of a new product shall be subjected to type inspection. For a new product series, only the basic prototype of the series shall be subjected to type inspection. After passing the inspection, the prototype of a new product with lower power, lower discharge pressure and smaller boost range than the prototype may not be subjected to type inspection. 7.2.3 Products transferred from other factories shall be subject to type inspection. 7.2.4 Products shall be subject to type inspection when there are major changes in design, process and materials. 7.3 Sampling inspection
Pumps produced in batches shall be subject to sampling inspection. The inspection plan shall be the single sampling plan specified in Table 12. The sampling time shall be evenly distributed in 1a.
Batch range
51--90
91~150
7.4 Factory inspection
7.4.1 Each pump shall be subject to factory inspection.
Sample size n
Qualified judgment number Ac
Unqualified judgment number Re
7.4.2 During factory inspection, the various indicators of the pump shall comply with the provisions of Articles 5.5, 5.6 and 5.11. If all the indicators of the pump meet the above provisions, it is a qualified product. If one of the indicators in the above provisions is not met, it is a non-conforming product. 8
Marking, packaging and storage
The nameplate of the pump should be fixed on a conspicuous part of the pump, and the size and technical requirements of the nameplate should comply with the provisions of GB/T13306. The nameplate should include the following contents:
Manufacturer name;
Pump model and name;
Main technical specifications: rated flow, m/h; rated discharge pressure, MPa; rated boost pressure, MPa; pump speed, min-1: prime mover c.
Power, kW; weight, kg;
Factory number;
Year and month of production.
The pump should be marked with the registered trademark.
Important externally purchased supporting equipment of the pump should also have a nameplate. The transmission housing of the pump should have an indication of the direction of rotation of the crankshaft. Other important equipment that is only allowed to rotate in one direction should have an indication of the direction of rotation. The pump should be treated with rust prevention or paint. All passages to the atmosphere should be sealed. Flanges and welding grooves should be covered, and auxiliary pipelines with smaller diameters should be removed or temporarily supported.
8.6 The accompanying documents of the pump should include installation drawings, drawings of wearing parts, product instructions, packing lists, and product certificates. The documents should be wrapped in watertight plastic bags and placed in packaging boxes.
JB/T6538-92
The packaging of the pump should comply with the provisions of GB/T13384 and should be closed. 8.7
Under normal storage conditions, the manufacturer should ensure that the pump will not rust within six months from the date of shipment. Metering device
Supplementary pump
IB/T6538-92
Attachment A
System diagram of reciprocating booster pump test device
(reference)
Hongquan Road
Pressure slurry
Tested pump
Figure A1 Open test system
Heat exchanger
Shuliutao
Figure A2 Closed test system
PressureAll instrument readings shall be read and recorded at the same time. Each measured parameter shall be measured three times, and the arithmetic mean shall be taken as the measured value. The accuracy of the test instruments and meters shall comply with the provisions of Table 10. All measuring instruments and meters shall be within the effective use period and have a calibration certificate issued by the measurement department or relevant departments. Table 10 Measurement items Input power Speed ​​or rotation speed 6.3 Test requirements Only instruments and meters shall be corrected Type and sample inspection Factory inspection Test run, load endurance test, continuous operation test, performance test, safety valve (relief valve) test, explosion test, cleanliness inspection shall comply with the provisions of GB7784. Determination of the noise measurement point See Appendix B (reference).
Parameter measurement and data processing
The measurement and data processing of flow, pressure, temperature, speed and power shall comply with the provisions of GB7T84. Drawing of performance curve
The relationship curve between flow, power, pump efficiency and pressure difference at rated pump speed is shown in Figure 1. Test report
The content of type inspection report includes:
JB/T 653892
Efficiency,
Information on pump assembly and inspection of main parts before test: flow Q
Power P
Pressure difference pMPa
Information on pump disassembly inspection results and changes in the size of main friction pairs after test; test records, pump performance curve:
Conclusion of pump test;
Test device system diagram;
Information on test medium;
Calibration record of test instruments and meters. The contents of the sampling inspection report include:
Test records, pump performance curve;
Test conclusion.
The contents of the factory inspection report include:
Test records;
Test conclusion.
The test data shall be signed by the person in charge of the test. Inspection rules
General requirements
Each pump shall be inspected and qualified by the technical inspection department and accompanied by a product certificate before it can be shipped. The pump can only be put into trial operation after the main parts material, manufacturing accuracy, assembly accuracy inspection and hydraulic test are qualified. Various types of pump inspections shall be carried out according to the items specified in Table 11. Table 11
Test items
Trial operation
Load operation test
Continuous operation test
Performance test
Test items
Rated working condition performance inspection
Safety valve, relief valve test
Noise test
JB/T653892
Continued Table 11
Note: V-indicates that the test is to be carried out, and × indicates that the test is not to be carried out. 7.1.4 Under special circumstances, with the user's consent, the factory inspection allows the pump to be tested under deceleration or reduced pressure or on-site. 7.2 Type inspection
7.2.1 The first prototype of a new product shall be subjected to type inspection. For a new product series, only the basic prototype of the series shall be subjected to type inspection. After passing the inspection, the prototype of a new product with lower power, lower discharge pressure and smaller boost range than the prototype may not be subjected to type inspection. 7.2.3 Products transferred from other factories shall be subject to type inspection. 7.2.4 Products shall be subject to type inspection when there are major changes in design, process and materials. 7.3 Sampling inspection
Pumps produced in batches shall be subject to sampling inspection. The inspection plan shall be the single sampling plan specified in Table 12. The sampling time shall be evenly distributed in 1a.
Batch range
51--90
91~150
7.4 Factory inspection
7.4.1 Each pump shall be subject to factory inspection.
Sample size n
Qualified judgment number Ac
Unqualified judgment number Re
7.4.2 During factory inspection, the various indicators of the pump shall comply with the provisions of Articles 5.5, 5.6 and 5.11. If all the indicators of the pump meet the above provisions, it is a qualified product. If one of the indicators in the above provisions is not met, it is a non-conforming product. 8
Marking, packaging and storage
The pump nameplate should be fixed on a conspicuous part of the pump, and the size and technical requirements of the nameplate should comply with the provisions of GB/T13306. The nameplate should include the following contents: 8.1
Manufacturer name;
Pump model and name;
Main technical specifications: rated flow, m/h; rated discharge pressure, MPa; rated boost pressure, MPa; pump speed, min-1: prime mover c.
Power, kW; weight, kg;
Factory number;
Year and month of production.
The pump should be marked with the registered trademark.
Important externally purchased supporting equipment of the pump should also have a nameplate. The transmission housing of the pump should have an indication of the direction of rotation of the crankshaft. Other important equipment that is only allowed to rotate in one direction should have an indication of the direction of rotation. The pump should be treated with rust prevention or paint. All passages to the atmosphere should be sealed. Flanges and welding grooves should be covered, and auxiliary pipelines with smaller diameters should be removed or temporarily supported.
8.6 The accompanying documents of the pump should include installation drawings, drawings of wearing parts, product instructions, packing lists, and product certificates. The documents should be wrapped in watertight plastic bags and placed in packaging boxes.
JB/T6538-92
The packaging of the pump should comply with the provisions of GB/T13384 and should be closed. 8.7
Under normal storage conditions, the manufacturer should ensure that the pump will not rust within six months from the date of shipment. Metering device
Supplementary pump
IB/T6538-92
Attachment A
System diagram of reciprocating booster pump test device
(reference)
Hongquan Road
Pressure slurry
Tested pump
Figure A1 Open test system
Heat exchanger
Shuliutao
Figure A2 Closed test system
Pressure1 The first prototype of a new product shall be subject to type inspection. For new products in a series, only the basic prototype of the series shall be subject to type inspection. After passing the inspection, the prototype of a new product with lower power, lower discharge pressure and smaller boost range than the prototype may not be subject to type inspection. 7.2.3 Products transferred from other factories shall be subject to type inspection. 7.2.4 Products shall be subject to type inspection when there are major changes in design, process and materials. 7.3 Sampling inspection
Pumps produced in batches shall be subject to sampling inspection. The inspection plan shall be a single sampling plan as specified in Table 12. The sampling time shall be evenly distributed in 1a.
Batch range
51--90
91~150
7.4 Factory inspection
7.4.1 Each pump shall be subject to factory inspection.
Sample size n
Number of qualified judgments Ac
Number of unqualified judgments Re
7.4.2 During factory inspection, the various indicators of the pump shall comply with the provisions of Articles 5.5, 5.6 and 5.11. If the pump meets all the above-mentioned indicators, it is a qualified product. If one of the above-mentioned indicators is not met, it is a unqualified product. 8
Marking, packaging and storage
The nameplate of the pump shall be fixed in a conspicuous position of the pump, and the size and technical requirements of the nameplate shall comply with the provisions of GB/T13306. The nameplate shall include the following information: 8.1
Manufacturer name;
Pump model and name;
Main technical specifications: Rated flow, m/h; Rated discharge pressure, MPa; Rated boost pressure, MPa; Pump speed, min-1: Prime motor power, kW; Weight, kg;
Factory number;
Year and month of production.
The pump shall be marked with the registered trademark.
Important externally purchased supporting equipment of the pump shall also have a nameplate. The transmission housing of the pump shall have an indication of the direction of rotation of the crankshaft. Other important equipment that is only allowed to rotate in one direction shall have an indication of the direction of rotation. The pump shall be treated with rust prevention or paint. All passages to the atmosphere shall be sealed. Flanges and welding grooves should be covered, and auxiliary pipelines with smaller diameters should be removed or temporarily supported.
8.6 The accompanying documents of the pump should include installation drawings, drawings of wearing parts, product instructions, packing lists, and product certificates. The documents should be wrapped in watertight plastic bags and placed in the packaging box.
JB/T6538-92
The packaging of the pump should comply with the provisions of GB/T13384 and should be closed. 8.7
Under normal storage conditions, the manufacturer should ensure that the pump will not rust within six months from the date of shipment. Metering device
Supplementary pump
IB/T6538-92
Attachment A
System diagram of reciprocating booster pump test device
(reference)
Hongquan Road
Pressure slurry
Tested pump
Figure A1 Open test system
Heat exchanger
Shuliutao
Figure A2 Closed test system
Pressure1 The first prototype of a new product shall be subject to type inspection. For new products in a series, only the basic prototype of the series shall be subject to type inspection. After passing the inspection, the prototype of a new product with lower power, lower discharge pressure and smaller boost range than the prototype may not be subject to type inspection. 7.2.3 Products transferred from other factories shall be subject to type inspection. 7.2.4 Products shall be subject to type inspection when there are major changes in design, process and materials. 7.3 Sampling inspection
Pumps produced in batches shall be subject to sampling inspection. The inspection plan shall be a single sampling plan as specified in Table 12. The sampling time shall be evenly distributed in 1a.
Batch range
51--90
91~150
7.4 Factory inspection
7.4.1 Each pump shall be subject to factory inspection.
Sample size n
Number of qualified judgments Ac
Number of unqualified judgments Re
7.4.2 During factory inspection, the various indicators of the pump shall comply with the provisions of Articles 5.5, 5.6 and 5.11. If the pump meets all the above-mentioned indicators, it is a qualified product. If one of the above-mentioned indicators is not met, it is a unqualified product. 8
Marking, packaging and storage
The nameplate of the pump shall be fixed in a conspicuous position of the pump, and the size and technical requirements of the nameplate shall comply with the provisions of GB/T13306. The nameplate shall include the following information: 8.1
Manufacturer name;
Pump model and name;
Main technical specifications: Rated flow, m/h; Rated discharge pressure, MPa; Rated boost pressure, MPa; Pump speed, min-1: Prime motor power, kW; Weight, kg;
Factory number;
Year and month of production.
The pump shall be marked with the registered trademark.
Important externally purchased supporting equipment of the pump shall also have a nameplate. The transmission housing of the pump shall have an indication of the direction of rotation of the crankshaft. Other important equipment that is only allowed to rotate in one direction shall have an indication of the direction of rotation. The pump shall be treated with rust prevention or paint. All passages to the atmosphere shall be sealed. Flanges and welding grooves should be covered, and auxiliary pipelines with smaller diameters should be removed or temporarily supported.
8.6 The accompanying documents of the pump should include installation drawings, drawings of wearing parts, product instructions, packing lists, and product certificates. The documents should be wrapped in watertight plastic bags and placed in the packaging box.
JB/T6538-92
The packaging of the pump should comply with the provisions of GB/T13384 and should be closed. 8.7
Under normal storage conditions, the manufacturer should ensure that the pump will not rust within six months from the date of shipment. Metering device
Supplementary pump
IB/T6538-92
Attachment A
System diagram of reciprocating booster pump test device
(reference)
Hongquan Road
Pressure slurry
Tested pump
Figure A1 Open test system
Heat exchanger
Shuliutao
Figure A2 Closed test system
Pressure
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.