This standard specifies the monitoring content, monitoring methods and qualified indicators of the energy utilization status of industrial boilers. This standard applies to industrial steam boilers with a rated evaporation capacity greater than 0.7MW (1t/h) and less than 24.5MW (35t/h) and industrial hot water boilers with a rated heating capacity greater than 2.5GJ/h. GB/T 15317-1994 Industrial Boiler Energy Saving Monitoring Method GB/T15317-1994 Standard Download Decompression Password: www.bzxz.net
Some standard content:
UDC621.772-620.9 National Standard of the People's Republic of China GB/T 15317-94 Monitoring and testing method forenergy saving of industrial boilers1994-12-17Promulgated Implementation on 1995-10-01 State Technical Supervision Bureau National Standard of the People's Republic of China Monitoring and testing method forenergy saving of industrial boilers Monitoring and testing method forenergy saving of industrial boilers1 Subject content and applicable examples This standard specifies the monitoring content, monitoring methods and comprehensive indicators for the energy utilization status of industrial boilers. GBT 1531794 This standard is applicable to industrial steam boilers with a rated evaporation capacity of less than 0.7MW (1t/h) and less than 24.5MW (35t/h), and industrial hot water boilers with a rated heating capacity greater than 2.5Gi/h. 2 Reference standards GB1531e Energy-saving monitoring technology GR/3486 Evaluation of enterprise's reasonable investment technology GB/T6422 Enterprise consumption measurement and test guidance GB/T10180T Industrial boiler heat test specification 2JS117. Finding conditions in industrial boiler maintenanceWww.bzxZ.net 3 Industrial boiler maintenance energy-saving monitoring items 3.1 Monitoring and inspection objectives 3.1. Energy-saving monitoring of industrial boilers should examine thermal efficiency. 3.1.2 The test of thermal efficiency shall comply with the following provisions: The test of thermal efficiency shall be carried out in accordance with B/11018: The thermal efficiency data provided by the enterprise shall be based on the test report (record A) of the professional unit. b, thermal efficiency test shall be carried out under the following conditions: After the industrial boiler is newly installed and overhauled, and after technical transformation, the thermal efficiency test time shall not exceed one year: 3.2 Monitoring test items 3.2.1 Smoke mixing degree 3-2.2 Smoke gas coefficient. 3.2.3 Carbon content of furnace materials: 3.2.4 Furnace body surface temperature. 4 Industrial boiler energy-saving monitoring method 4.1 Steel monitoring test sound is carried out under the actual operating conditions of normal production. 4.? Parting time: Start from the thermal condition reaching the set state, and the monitoring time should be no less than 1h. Except for the test day that needs to be analyzed, the readings shall be recorded once every 15 minutes and the average value shall be calculated. 4.3 The instrument of the monitoring station shall be able to meet the requirements of the two-distance salt measurement items. The instrument must be in good condition and within the calibration period. Its accuracy shall not be lower than GB/T 15317-94 approved by the State Bureau of Technical Supervision on December 17, 1994 and October 01, 1995. The test point of the exhaust source shall be carried out on the flue within 1m behind the last stage of the tail heating surface of the industrial furnace. The metering thermocouple shall be placed in the flue to ensure the sealing of the flue. 4.5 Air coefficient The air sampling should be at the center of the flue within the highest and lowest tail heating surface of the industrial boiler. The air sampling and temperature measurement should be carried out simultaneously: The air coefficient is calculated according to formula (1): O, 0.5C0. 2CI 27 - 79 TGG (RO + 0. +TO+ H, + CH,1 Wherein, RO, CO.CH, H.- are the percentage contents of combustion products. For gas and filter fuels, H, and CH are not analyzed. 4.5 For furnaces equipped with mechanical ash removal equipment, samples can be taken regularly at the fire outlet (usually once every 15 to 2 minutes). Pay attention to the uniformity and representativeness of the samples: The initial number of samples should not be less than 3% of the total amount collected. When the coal content is greater than or equal to the amount collected, the number of original samples should not be less than 10% of the total amount collected. But the total ash quantity is less than 20kg. When the total ash quantity is less than 20g, all samples should be taken. The number of samples after the reduction should be no less than 2kg-1kg. After 1k sealing, check, 4.7 The arrangement of the outer surface temperature of the outer protective body should have representative life, "0.3--] m measuring points should be averaged and the furnace door should be burned. The hole should be probed, etc. should not be arranged within the range of 30nm. 5 Industrial boiler energy-saving monitoring qualified indicators 5. 1 The qualified index of thermal efficiency is shown in Table 1. Table 1 The qualified index of thermal efficiency is shown in Table 1. 5.2 The qualified index of exhaust temperature is shown in Table 2, thermal efficiency is shown in Table 2, rated heat capacity, W, rated standard heat, GJ/h, exhaust temperature, 5.3 The qualified index of air coefficient is shown in Table 3. 5.4 The qualified index of latent heat is shown in Table 4. GE/T15317-94 Table 2 The qualified index of smoke intensity is shown in Table 2. 6--1. 2 10~-15 Table of qualified indexes of air coefficient Table 4 Qualified indexes of carbon content in furnace 5.5 Qualified indexes of short quality of outer surface of furnace body See Table 5 Table points: Qualified indexes of outer surface temperature of furnace guard body Guard body surface i.e. whole skin Charm oil, natural gas Youzhou Refining 5-E For Haikong 2 00 m In industrial areas, the qualified indicators of energy conservation monitoring can be adjusted by local energy conservation departments according to the actual situation. 6 Evaluation of industrial furnace energy conservation monitoring results 6.1 The qualified indicators and test items of industrial furnace energy conservation inspection items stipulated in this standard are the lower standards for qualified monitoring. The test items should be used to evaluate the unqualified and qualified ones. Only when all the monitoring indicators are qualified can they be regarded as "energy conservation qualified industrial screening". 6.2 For those who are unqualified, the monitoring unit should make a report on the degree of energy conservation and put forward improvement suggestions. : The monitoring unit of the energy conservation business furnace Thermal induced heat Emission degree Broad-gas coefficient The carbon content of the furnace The outer surface quality of the protective film ! (Investment person) Additional notes: GA/T15317-92 Appendix A Industrial boiler energy conservation monitoring report (supplement) Measurement data Evaluation points, processing notes and settings: Monitoring annual Monitoring data Qualified network standard No.: Monitoring establishment chapter) 4 The standard is proposed by the Department of Chemical Engineering, the Department of Resource Conservation and Comprehensive Utilization of the State Economic and Trade Commission, and this standard is supported by the Technical Committee of the National Energy Administration and the Technical Committee of the National Energy Administration. This standard was drafted by China Institute of Standardization and Information Technology, National Energy Conservation Monitoring Center and China Energy Conservation Research Institute under the State Planning Commission. The drafters of this standard are Xin Ding, Fan Bobang, Li Aixian, Wang Hanyu, Ye Yuanqi, etc. Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.