title>GB 17905-1999 Safety Management Regulations for Household Gas Burning Appliances - GB 17905-1999 - Chinese standardNet - bzxz.net
Home > GB > GB 17905-1999 Safety Management Regulations for Household Gas Burning Appliances
GB 17905-1999 Safety Management Regulations for Household Gas Burning Appliances

Basic Information

Standard ID: GB 17905-1999

Standard Name: Safety Management Regulations for Household Gas Burning Appliances

Chinese Name: 家用燃气燃烧器具安全管理规程

Standard category:National Standard (GB)

state:Abolished

Date of Release1999-11-23

Date of Implementation:2000-06-01

Date of Expiration:2005-02-01

standard classification number

Standard ICS number:Building Materials and Buildings>>Facilities in Buildings>>91.140.99 Other Facilities in Buildings

Standard Classification Number:Building Materials>>Public and Municipal Construction Equipment>>Q82 Gas Supply Equipment

associated standards

alternative situation:Replaced by GB 17905-2004

Procurement status:GOST 19910-1994 NEQ

Publication information

other information

Review date:2004-10-14

Drafting unit:Beijing Gas Appliances Factory

Focal point unit:Ministry of Construction

Publishing department:State Administration of Quality and Technical Supervision

Introduction to standards:

This standard specifies the production, installation, acceptance, use, maintenance, repair, scrapping and accident handling of household gas burning appliances. This standard applies to household gas burning appliances using town gas. GB 17905-1999 Safety Management Regulations for Household Gas Burning Appliances GB17905-1999 Standard download and decompression password: www.bzxz.net

Some standard content:

GB17905--1999
Foreword
With the development of the gas industry and the wide application of gas burning appliances, especially the gradual popularization of gas water heaters, safety accidents and personal accidents also occur from time to time, causing great harm to people's lives and property. It caused some losses and attracted the attention of the majority of users. In order to prevent and reduce the occurrence of accidents, it is necessary to formulate this standard and carry out standardized management from production, sales, installation, use, maintenance, scrapping and accident handling.
This standard refers to Japanese, Russian and other national standards, such as: FOCT19910-1994 "Household Gas Instant Water Heater" standard, and also absorbs and adopts GB6932-1994 "Household Gas Instant Water Heater", GB16410-1996 "Household Gas Cooker" ", GB16914-1997 "General Safety Technical Principles for Gas Burning Appliances", GB50028-1993 "Urban Gas Design Code" and other standards have some provisions. Appendix A, Appendix B, Appendix C and Appendix D of this standard are all appendices of the standard. This standard is proposed by the Ministry of Construction of the People's Republic of China. This standard is under the jurisdiction of China Municipal Engineering North China Design and Research Institute, the technical focal point for urban gas standards under the Ministry of Construction. This standard was drafted by: Beijing Gas Appliances Factory. Units participating in the drafting of this standard: China Municipal Engineering North China Design and Research Institute, Beijing Gas Company, Beijing Natural Gas Company, Shanghai Gas Sales (Group) Co., Ltd., Shenyang Gas Corporation, Chengdu Shengduo Gas Manufacturing Co., Ltd. The main drafters of this standard: Wu Shiyi, Liu Shicai, Gao Yong, Li Meizhu, Yang Yongqiang, Jin Shihao, Wang Hongwei, Xu Xijun. 802
National Standard of the People's Republic of China
Safety management rules of gas-burning appliances for domestic use1Scope
GB17905-1999
This standard It stipulates the production, installation, acceptance, use, maintenance, repair, scrapping and accident handling of household gas burning appliances. This standard applies to household gas burning appliances using town gas. 2 Referenced Standards
"The provisions contained in the following standards constitute provisions of this standard by reference in this standard. When this standard is published, the versions indicated are valid. All references will be revised, use Parties to this standard should explore the possibility of using the latest versions of the following standards: GB6932-1994 Household gas instant water heaters GB16410-1996 Household gas stoves
GB/T16411~-1996 General test methods for household gas appliances GB16914-1997 General Safety Technical Principles for Gas Burning Appliances GB50028--1993 Urban Gas Design Code CJJ12--1999 Installation and Acceptance Regulations for Household Gas Burning Appliances 3 Definitions
This standard adopts the following definitions
3.1 Urban gas city gas, Town gas refers to gas that meets the standard gas quality requirements and is supplied to residents, businesses (public buildings) and industrial enterprises for public use as fuel. Town gas generally includes natural gas, liquefied petroleum gas and artificial gas. 3.2 Household gas burning appliances. Domestic gas-burning appliances for urban residents use household gas instant water heaters, household gas stoves, etc. 4 Production, type inspection and sales of burning appliances
4.1 Production management of gas water heaters
Production and implementation of gas water heaters Production license system, gas water heaters must obtain the national gas water heater product production license before production
4.2 Type inspection
4.2.1 The state-authorized burning appliance testing center (station) should have burning appliances. Type inspection capabilities and type inspection equipment should be complete. 4.2.2 The manufacturer of burning appliances should submit an application for product type inspection to the state-authorized burning appliance testing center (station), and the products must go through the type inspection bench
4.2. 3. When a burning appliance manufacturer provides a prototype for type inspection of a burning appliance, it should also provide product photos, product structure and action schematic diagrams, and a registration list of relevant component materials and structural types. 4.2.4 Nationally authorized burning appliance testing center (station). The type inspection report and certificate of burning appliances shall be issued to the submitter in accordance with the standards for type inspection of burning appliances. Approved by the State Administration of Quality and Technical Supervision on 1999-11~23 and implemented on 2000-06-01
803
GB 17905 -1999 | The photos and type classification details shall be registered, saved and kept confidential
4.2.6 The type inspection report and certificate of burning appliances shall be valid for 5 years. The type inspection shall be carried out again when the fuel is in the following circumstances; a) The product is transferred. Factory production, trial production, finalization, and appraisal; b) After formal production, if there are major changes in structure, materials, and processes that may affect product performance; c) When the product resumes production after one year of suspension; d) The factory inspection results are the same as the last time When there are large differences in type inspection; e) When the national quality supervision agency proposes type inspection requirements. 4.3 Sales of burning appliances
4.3.1 Sellers of burning appliances should sell gas water heaters with production licenses and burning appliances that have passed type inspection and have type inspection certificates.
4.3.2 Producers of burning appliances should accept product supervision and sampling inspections proposed by national and provincial (municipal) quality and technical supervision departments; product supervision and sampling inspections should mainly test the safety performance of burning appliance products.
4.3.3 When burning appliances are sold, the inspection agency designated by the local quality and technical supervision department should conduct a gas suitability inspection on the artificial gas burning appliances. The suitability inspection only tests the combustion conditions of the burning appliances. 4.3.4 After passing the inspection, the local gas authority shall publish the catalog of qualified burning appliances to the public on a regular basis. 4.3.5 Inspection departments at all levels of burning appliances shall be responsible for the authenticity and accuracy of the inspection reports produced; if the manufacturer of burning appliances has any doubts about the inspection results, he may apply for a reply to the higher-level inspection agency within fifteen days of receiving the inspection report. Inspection 4.3.6 Burning appliances that are specially exported or used only for testing are not subject to the above restrictions; however, exported products must undergo type inspection in accordance with regulations when sold domestically.
5 Installation and acceptance of burning appliances
5.1 Users must apply to the local gas supply company to use burning appliances, and they can only be used after approval. Users are not allowed to install or remove burning appliances without approval.
5.2 Gas supply enterprises are responsible for the management of gas users, establishing user files, formulating user safety regulations, responsible for user safety education, and popularizing gas knowledge
5.3 Supervision and management of the installation and use of burning appliances This is the responsibility of the local gas authority. 5.4 The installation and modification of burning appliances must be carried out by personnel who have received professional training and have obtained the qualification review of the local gas authority. After the burning appliance is installed, the supervisory personnel of the installation unit shall inspect, register and issue an installation qualification mark, which shall be affixed to a visible part of the casing of the burning appliance. When installing burning appliances, attention should be paid to the smoke exhaust and ventilation of the burning appliances to ensure their safe use. 5.5 The gas supply enterprise shall organize the inspection and acceptance of the installed and modified burning appliances in accordance with the relevant standards and specifications of the gas appliances. Only after they are qualified and registered can they be used for gas use.
5.6 The installation, supervision, and maintenance personnel of burning appliances must bring valid certificates to work and ensure the quality of installation and modification. After installation and modification, the debugging must be qualified, and the acceptance personnel shall conduct on-site acceptance, and the user shall sign the acceptance form. 6 Use, maintenance, repair and disposal of burning appliances 6.1 To ensure the safe use of burning appliances, gas management departments, gas supply companies and burning appliance manufacturers should publicize safe use regulations to users and operate in strict accordance with the product instruction manual.
6.2 When users of burning appliances choose imported burning appliances from abroad, they should submit them to the quality inspection department for inspection. 6.3 The manufacturer of burning appliances should set up a maintenance station at the place of sale or entrust a local gas supply company to be responsible for the after-sales service and maintenance of burning appliances. The manufacturer of burning appliances should provide the spare parts needed for maintenance. 6.4 When using burning appliances, users should always pay attention to the usage conditions. If any abnormalities are found, they should immediately ask the maintenance unit to repair them. The maintenance sites of burning appliances and 80-4
GB 17905-1999
gas supply companies should accept the user's entrustment to conduct safety inspections of burning appliances and conduct inspection registration. For problematic burning appliances, written maintenance opinions should be submitted and filed for registration. The inspection contents are as follows: a) function of each operating component;
b) flame stability when the burner is burning,
c) exhaust Clean the carbon deposits at the smoke outlet;
d) Flue sealing and suction force:
e) Whether the flue and the supply and exhaust pipes are blocked; whether the supply and exhaust systems are smooth; f) Clean or Replace wearing parts.
6.5 Disposal of burning appliances
6.5.1 From the date of sale, the scrapping period for gas water heaters shall be 6 years, and for liquefied petroleum gas and natural gas water heaters shall be 8 years. The scrapping period for gas stoves shall be 8 years. 6.5.2 After overhaul, if any of the following faults still occur in the gas water heater, it shall be scrapped; a) The combustion condition is seriously deteriorated, and the carbon monoxide content in the flue gas still does not meet the requirements of 7.5 after overhaul; b) The combustion chamber and heat exchanger are seriously burned and the flame is exposed; c) Water leakage and gas leakage.
7 Accident handling
7.1 When an accident occurs to the user of the gas appliance, the gas source shall be cut off immediately, the doors and windows shall be opened for ventilation, and the injured shall be carried to a well-ventilated place for emergency treatment or sent to the hospital immediately for treatment.
7.2 The first witness shall protect the scene and immediately notify the relevant departments to survey the scene and seal the gas appliance. 7.3 The accident handling shall be conducted by the gas competent department in conjunction with the public security, fire protection, labor and other relevant departments to form an accident investigation team to investigate and handle the accident. 7.4 When handling a gas appliance accident, the accident investigation team shall entrust the relevant departments to make four technical appraisal certificates for the accident according to the relevant standards and regulations of the gas appliance (see Appendix A, Appendix B, Appendix C, Appendix D): a) Gas appliance installation and smoke exhaust; b) Gas appliance use and maintenance; c) Gas and supply quality; d) Gas appliance quality. 7.5 When re-inspecting the accident gas appliance, the re-inspection unit shall remove foreign matter from the accident gas appliance and conduct inspections according to different accident types: a) Carbon dioxide poisoning accident: 1) Gas tightness of the gas appliance; 2) Flame stability (limit gas); 3) Carbon dioxide content in the flue gas (0-2 gas). Gas appliances sold within one year should comply with the provisions of GB6932; gas appliances sold for more than one year, direct-discharge gas water heaters should be less than 0.14%, flue-type and balanced gas water heaters should be less than 0.28%, and gas stoves should be less than 0.14%.
b) Accidents caused by gas leakage:
1) Air tightness of gas pipelines and gas appliances;
2) The gas inlet of the gas appliance should have a leakage of less than 0.07L/h under an air pressure of 4.2kPa. 7.6 Units and personnel who install, modify, or repair without obtaining the qualification certification of the local gas authority shall be held criminally liable by the judicial authorities for accidents caused by installation, modification, or repair, if the circumstances are serious enough to constitute a crime; if it does not constitute a crime, they shall be punished in accordance with the provisions of relevant laws and regulations.
7. If a violation of the regulations causes casualties, the responsible party shall compensate the victim's medical expenses, income lost due to work stoppage, living allowance for the disabled, funeral expenses, pensions, necessary living expenses for the deceased's dependents during his lifetime, and direct property losses. 805
Product name
Serial number
2
3
Installation site
Direct exhaust
Exhaust
Smoke
Vent
Wind
Flue
Balanced
Project
Qualification
Model
Permitted
Technical permission
Stove
Water heater
Natural exhaust
Forced exhaust
Natural supply and exhaust
Forced supply and exhaust
GB 17905--1999
Appendix A
(Appendix to the standard)
Installation of fuel-burning appliances and smoke exhaust ventilation
Production unit
Content
Qualification certification of installation units
Training certification of installation personnel
Kitchen, veranda, balcony, outdoor
Content
Bedroom, basement, bathroom, flammable, explosive and corrosive rooms are equipped with natural exhaust hoods, forced exhaust hoods, ventilation fans, exhaust fans and their linkage devices
Exhaust flue exits positive pressure area
Exhaust pipe, exhaust hood, exhaust fan linkage
Exhaust and exhaust are simply connected to the outdoors or public flue. Exhaust and exhaust are simply connected to the outdoors
Note: The installation site and smoke exhaust ventilation should comply with the provisions of GB1694 and CJ12. Appendix B
(Appendix to the standard)
Use and maintenance of burning appliances
B1 Check the correct use of burning appliances by users according to the instructions for use of burning appliances. B2 Check the maintenance of burning appliances according to the instructions for use of burning appliances. Appendix C
(Appendix to the standard)
Gas and supply quality
Table C1 Gas categories
Yingmu
Artificial coal gas
Natural gas
Liquefied petroleum gas
806
47
6T
Gas categories
5R
7R
6R|| tt||7T
19Y
10r
12T
22Y
20Y
13T
Huabai number
Production date
Air inlet area
9.5cm2/kw
Air inlet area is greater than
Exhaust pipe area
Combustion potential C.
Conclusion
Conclusion
Project
Artificial gas
Natural gas
Bottled liquefied petroleum gas
GB17905—1999
Table C2 Gas supply pressure
Rated pressure/Pa
1000
2 000
2800
Note: Pipeline liquefied petroleum gas is 0.75~1.5pa. The quality of urban gas should comply with the provisions of 2.2 in GB50028—1993. Fluctuation range
0.75~1.5pa 5p rating
±0.5kPa
Appendix D
(Standard Appendix)
Mass of Burning Appliances
Product Name
Serial Number
2
3
Test Items
Fire
Flame
Stability
|Smoke
Medium
Ring
Chemical
Carbon
Content
Backfire
Flameout
Flame separation
Stove
Exhaust
Type
Heat
Water
Air tightness
Smoke
|Valve
Almost
|tt||Type
Model
Production unit
Performance requirements
Visually check whether the main fire burner is backfired 20 minutes after it is ignited. Visually check whether each fire hole has flame 15s after the main fire burner is ignited. Visually check whether one-third of the fire holes of a single burner are away from the flame 15s after the main fire burner is ignited in a cold state.
Should comply with national standards within one year from the date of sale. Should not exceed 0.14% within one year from the date of sale. Should not exceed 0.14% within one year from the date of sale. Should comply with national standards within one year from the date of sale. Should not exceed 0.28% within one year from the date of sale. The leakage of imported burning appliances under 4.2kPa air pressure should be less than 0.07L/h. Note: The meaning of the test gas quality conditions is detailed in GB/T16411. Production date
Conclusion
Test gas conditions
2-3
3-1
3-3
3-1
0-2
0-2
Air
Conclusion
807
4. When dealing with a burning appliance accident, the accident investigation team should entrust the relevant departments to issue four technical appraisal certificates for the accident in accordance with relevant standards and regulations for burning appliances (see Appendix A, Appendix B, Appendix C, and Appendix D): a) Burning appliance Installation and smoke exhaust;
b) Use and maintenance of burning appliances;
c) Gas and supply quality;
d) Quality of burning appliances.
7.5 When re-inspecting accidental burning appliances, the re-inspection unit shall remove foreign objects from the accidental burning appliances and conduct inspections according to different accident types: a) - Carbon oxide poisoning accident:
1) Air tightness of burning appliances properties;
2) Flame stability (boundary gas);
3) Carbon oxide content in flue gas (0-2 gas). Burning appliances should comply with the regulations in GB6932 within one year after they are sold; if they are sold for more than one year, the direct exhaust gas water heaters should be less than 0.14%, the flue type and balanced gas water heaters should be less than 0.28%, and the gas stoves should be less than 0.14%.
b) Accidents caused by gas leakage:
1) Air tightness of gas pipelines and burning appliances;
2) Gas inlets of burning appliances leak under 4.2kPa air pressure The amount should be less than 0.07L/h. 7.6 Installation, modification, and maintenance units and personnel who have not obtained the qualification certification of the local gas authority will be held criminally responsible by the judicial authorities if the accidents caused by the installation, modification, or maintenance are serious enough to constitute a crime; if it does not constitute a crime, they will be held criminally responsible according to relevant laws. , and impose penalties in accordance with the provisions of laws and regulations.
7. When a casualty accident occurs due to violation of regulations, the employer shall compensate the victim's medical expenses, loss of income due to missed work, living allowances for the disabled, death and funeral expenses, pensions, and dependents of the deceased. Necessary living expenses and direct loss of property. 805
Product name
Serial number
2
3
Installation site
Straight type
Row||tt ||Smoke
Tong
Wind
Fume type
Balanced type
Project
Qualification
Model|| tt||allowed
technical charging allowed
stove
water heater
natural exhaust
forced exhaust
natural exhaust
Forced exhaust supply
GB 17905--1999
Appendix A
(standard appendix)
Burning appliance installation and smoke exhaust ventilation|| tt||Production unit
Inside
Installation unit qualification certification
Installer training certification
Kitchen, verandah, balcony, outdoor
Content|| tt||Bedrooms, basements, bathrooms, flammable, explosive, and corrosive rooms are equipped with natural exhaust hoods, forced exhaust hoods, ventilation fans, exhaust fans and their linkage devices
The exhaust flue exits the positive pressure area
Exhaust pipe, exhaust hood, exhaust fan linkage
The supply and exhaust are simply connected to the outdoors or the public flue is connected to the outdoors
Note: Installation site, Smoke exhaust ventilation should comply with the regulations in GB1694 and CJ12. Appendix B
(standard appendix)
Use and maintenance of burning appliances
B1 Check the user's correct use of burning appliances according to the instructions for use of the burning appliance product. B2 Check the maintenance status of the burning appliance according to the instructions for use of the burning appliance product. Appendix C
(standard appendix)
Gas and supply quality
Table C1 Gas category
Eime
Artificial gas
Natural gas
LPG
806
47
6T
Gas category
5R
7R
6R
7T
19Y
10r
12T
22Y
20Y
13T
Huabai Number
Production date
Air inlet area
9.5cm2/kw
The air inlet area is greater than
The simple area of ??the exhaust pipe||tt| |Combustion potential C.
Conclusion
Conclusion
Project
Artificial gas
Natural gas
Bottled liquefied petroleum gas
GB17905—1999|| tt||Table C2 gas supply pressure
rated pressure/Pa
1000
2 000
2800
Note, pipeline liquefied petroleum gas is 0.75~ 1.5p amount. The quality of urban gas should comply with the provisions of 2.2 in GB50028-1993. Fluctuation range
0. 75~~1. 5 b amount
0.75~1. 5p amount
±0.5kPa
Appendix D
(standard appendix)
Quality of burning appliances
Product name
Serial number
2
3
Test items
Fire| |tt||Flame
Stable
Stable
Sex
Smoke

ridge
化||tt ||Carbon
Containing
Quantity
Tempering
Turn off the flame
Off the flame
Stove
Rack||tt ||Form
Hot
Water
Air tightness
Smoke
Tao
Hu
Form||tt ||Model
Production unit
Performance requirements
After the main fire burner is lit for 20 minutes, visually check whether the fire melt has tempered. After the main fire burner is lit for 15 seconds, visually check whether each fire hole is present. After 15 seconds of igniting the main fire burner in a cold flame state, it is visually inspected that one-third of the flame hole in a single burner has left the flame
It should comply with national standards within one year from the date of sale. It should not be greater than 0.14% from the date of sale for more than one year. It should comply with national standards within one year. The date of sale should not exceed 0.14% for more than one year. It should comply with national standards within one year. 0.07L/h Note: For details on the meaning of test temperament conditions, please refer to GB/T16411. Production date
Judgment conclusion
Test temperament conditions
2-3
3-1
3-3
3-1| |tt||0-2
0-2
0-2
air
Conclusion
807
4. When dealing with a burning appliance accident, the accident investigation team should entrust the relevant departments to issue four technical appraisal certificates for the accident in accordance with relevant standards and regulations for burning appliances (see Appendix A, Appendix B, Appendix C, and Appendix D): a) Burning appliance Installation and smoke exhaust;
b) Use and maintenance of burning appliances;
c) Gas and supply quality;
d) Quality of burning appliances.
7.5 When re-inspecting accidental burning appliances, the re-inspection unit shall remove foreign objects from the accidental burning appliances and conduct inspections according to different accident types: a) - Carbon oxide poisoning accident:
1) Air tightness of burning appliances properties;
2) Flame stability (boundary gas);
3) Carbon oxide content in flue gas (0-2 gas). Burning appliances should comply with the regulations in GB6932 within one year after they are sold; if they are sold for more than one year, the direct exhaust gas water heaters should be less than 0.14%, the flue type and balanced gas water heaters should be less than 0.28%, and the gas stoves should be less than 0.14%.
b) Accidents caused by gas leakage:
1) Air tightness of gas pipelines and burning appliances;
2) Gas inlets of burning appliances leak under 4.2kPa air pressure The amount should be less than 0.07L/h. 7.6 Installation, modification, and maintenance units and personnel who have not obtained the qualification certification of the local gas authority will be held criminally responsible by the judicial authorities if the accidents caused by the installation, modification, or maintenance are serious enough to constitute a crime; if it does not constitute a crime, they will be held criminally responsible according to relevant laws. , and impose penalties in accordance with the provisions of laws and regulations.
7. When a casualty accident occurs due to violation of regulations, the employer shall compensate the victim's medical expenses, loss of income due to missed work, living allowances for the disabled, death and funeral expenses, pensions, and dependents of the deceased. Necessary living expenses and direct loss of property. 805
Product name
Serial number
2
3
Installation site
Straight type
Row||tt ||Smoke
Tong
Wind
Fume type
Balanced type
Project
Qualification
Model|| tt||allowed
technical charging allowed
stove
water heater
natural exhaust
forced exhaust
natural exhaust
Forced exhaust supply
GB 17905--1999
Appendix A
(standard appendix)
Burning appliance installation and smoke exhaust ventilation|| tt||Production unit
Inside
Installation unit qualification certification
Installer training certification
Kitchen, verandah, balcony, outdoor
Content|| tt||Bedrooms, basements, bathrooms, flammable, explosive, and corrosive rooms are equipped with natural exhaust hoods, forced exhaust hoods, ventilation fans, exhaust fans and their linkage devices
The exhaust flue exits the positive pressure area
Exhaust pipe, exhaust hood, exhaust fan linkage
The supply and exhaust are simply connected to the outdoors or the public flue is connected to the outdoors
Note: Installation site, Smoke exhaust ventilation should comply with the regulations in GB1694 and CJ12. Appendix B
(standard appendix)
Use and maintenance of burning appliances
B1 Check the user's correct use of burning appliances according to the instructions for use of the burning appliance product. B2 Check the maintenance status of the burning appliance according to the instructions for use of the burning appliance product. Appendix C
(standard appendix)
Gas and supply quality
Table C1 Gas category
Eime
Artificial gas
Natural gas
LPG
806
47
6T
Gas category
5R
7R
6R
7T
19Y
10r
12T
22Y
20Y
13T
Huabai Number
Production date
Air inlet area
9.5cm2/kw
The air inlet area is greater than
The simple area of ??the exhaust pipe||tt| |Combustion potential C.
Conclusion
Conclusion
Project
Artificial gas
Natural gas
Bottled liquefied petroleum gas
GB17905—1999|| tt||Table C2 gas supply pressure
rated pressure/Pa
1000
2 000
2800
Note, pipeline liquefied petroleum gas is 0.75~ 1.5p amount. The quality of urban gas should comply with the provisions of 2.2 in GB50028-1993. Fluctuation range
0. 75~~1. 5 b amount
0.75~1. 5p amount
±0.5kPa
Appendix D
(standard appendix)
Quality of burning appliances
Product name
Serial number
2
3
Test items
Fire| |tt||Flame
Stable
Stable
Sex
Smoke

ridge
化||tt ||Carbon
Containing
Quantity
Tempering
Turn off the flame
Off the flame
Stove
Rack||tt ||Form
Hot
Water
Air tightness
Smoke
Tao
Hu
Form||tt ||Model
Production unit
Performance requirements
After the main fire burner is lit for 20 minutes, visually check whether the fire melt has tempered. After the main fire burner is lit for 15 seconds, visually check whether each fire hole is present. After 15 seconds of igniting the main fire burner in a cold flame state, it is visually inspected that one-third of the flame hole in a single burner has left the flame
It should comply with national standards within one year from the date of sale. It should not be greater than 0.14% from the date of sale for more than one year. It should comply with national standards within one year. The date of sale should not exceed 0.14% for more than one year. It should comply with national standards within one year. 0.07L/h Note: For details on the meaning of test temperament conditions, please refer to GB/T16411. Production date
Judgment conclusion
Test temperament conditions
2-3
3-1
3-3
3-1| |tt||0-2
0-2
0-2
air
Conclusion
807
When an injury or death occurs due to violation of regulations, the employer shall compensate the victim for the medical expenses, loss of income due to missed work, living allowance for the disabled, death and funeral expenses, pensions, necessary living expenses for the deceased’s dependents and direct losses of property. . 805
Product name
Serial number
2
3
Installation site
Straight type
Row||tt ||Smoke
Tong
Wind
Fume type
Balanced type
Project
Qualification
Model|| tt||allowed
technical charging allowed
stove
water heater
natural exhaust
forced exhaust
natural exhaust
Forced exhaust supply
GB 17905--1999
Appendix A
(standard appendix)
Burning appliance installation and smoke exhaust ventilation|| tt||Production unit
Inside
Installation unit qualification certification
Installer training certification
Kitchen, verandah, balcony, outdoor
Content|| tt||Bedrooms, basements, bathrooms, flammable, explosive, and corrosive rooms are equipped with natural exhaust hoods, forced exhaust hoods, ventilation fans, exhaust fans and their linkage devices
The exhaust flue exits the positive pressure area
Exhaust pipe, exhaust hood, exhaust fan linkage
The supply and exhaust are simply connected to the outdoors or the public flue is connected to the outdoors
Note: Installation site, Smoke exhaust ventilation should comply with the regulations in GB1694 and CJ12. Appendix B
(standard appendix)
Use and maintenance of burning appliances
B1 Check the user's correct use of burning appliances according to the instructions for use of the burning appliance product. B2 Check the maintenance status of the burning appliance according to the instructions for use of the burning appliance product. Appendix C
(standard appendix)
Gas and supply quality
Table C1 Gas category
Eime
Artificial gas
Natural gas
LPG
806
47
6T
Gas category
5R
7R
6R
7T
19Y
10r
12T
22Y
20Y
13T
Huabai Number
Production date
Air inlet area
9.5cm2/kw
The air inlet area is greater than
The simple area of ??the exhaust pipe||tt| |Combustion potential C.
Conclusion
Conclusion
Project
Artificial gas
Natural gas
Bottled liquefied petroleum gas
GB17905—1999|| tt||Table C2 gas supply pressure
rated pressure/Pa
1000
2 000
2800
Note, pipeline liquefied petroleum gas is 0.75~ 1.5p amount. The quality of urban gas should comply with the provisions of 2.2 in GB50028-1993. Fluctuation range
0. 75~~1. 5 b amount
0.75~1. 5p amount
±0.5kPa
Appendix D
(standard appendix)
Quality of burning appliances
Product name
Serial number
2
3
Test items
Fire| |tt||FlamebZxz.net
Stable
Stable
Sex
Smoke

ridge
化||tt ||Carbon
Containing
Quantity
Tempering
Turn off the flame
Off the flame
Stove
Rack||tt ||Form
Hot
Water
Air tightness
Smoke
Tao
Hu
Form||tt ||Model
Production unit
Performance requirements
After the main fire burner is lit for 20 minutes, visually check whether the fire melt has tempered. After the main fire burner is lit for 15 seconds, visually check whether each fire hole is present. After 15 seconds of igniting the main fire burner in a cold flame state, it is visually inspected that one-third of the flame hole in a single burner has left the flame
It should comply with national standards within one year from the date of sale. It should not be greater than 0.14% from the date of sale for more than one year. It should comply with national standards within one year. The date of sale should not exceed 0.14% for more than one year. It should comply with national standards within one year. 0.07L/h Note: For details on the meaning of test temperament conditions, please refer to GB/T16411. Production date
Judgment conclusion
Test temperament conditions
2-3
3-1
3-3
3-1| |tt||0-2
0-2
0-2
air
Conclusion
807
When an injury or death occurs due to violation of regulations, the employer shall compensate the victim for the medical expenses, loss of income due to missed work, living allowance for the disabled, death and funeral expenses, pensions, necessary living expenses for the deceased’s dependents and direct losses of property. . 805
Product name
Serial number
2
3
Installation site
Straight type
Row||tt ||Smoke
Tong
Wind
Fume type
Balanced type
Project
Qualification
Model|| tt||allowed
technical charging allowed
stove
water heater
natural exhaust
forced exhaust
natural exhaust
Forced exhaust supply
GB 17905--1999
Appendix A
(standard appendix)
Burning appliance installation and smoke exhaust ventilation|| tt||Production unit
Inside
Installation unit qualification certification
Installer training certification
Kitchen, verandah, balcony, outdoor
Content|| tt||Bedrooms, basements, bathrooms, flammable, explosive, and corrosive rooms are equipped with natural exhaust hoods, forced exhaust hoods, ventilation fans, exhaust fans and their linkage devices
The exhaust flue exits the positive pressure area
Exhaust pipe, exhaust hood, exhaust fan linkage
The supply and exhaust are simply connected to the outdoors or the public flue is connected to the outdoors
Note: Installation site, Smoke exhaust ventilation should comply with the regulations in GB1694 and CJ12. Appendix B
(standard appendix)
Use and maintenance of burning appliances
B1 Check the user's correct use of burning appliances according to the instructions for use of the burning appliance product. B2 Check the maintenance status of the burning appliance according to the instructions for use of the burning appliance product. Appendix C
(standard appendix)
Gas and supply quality
Table C1 Gas category
Eime
Artificial gas
Natural gas
LPG
806
47
6T
Gas category
5R
7R
6R
7T
19Y
10r
12T
22Y
20Y
13T
Huabai Number
Production date
Air inlet area
9.5cm2/kw
The air inlet area is greater than
The simple area of ??the exhaust pipe||tt| |Combustion potential C.
Conclusion
Conclusion
Project
Artificial gas
Natural gas
Bottled liquefied petroleum gas
GB17905—1999|| tt||Table C2 gas supply pressure
rated pressure/Pa
1000
2 000
2800
Note, pipeline liquefied petroleum gas is 0.75~ 1.5p amount. The quality of urban gas should comply with the provisions of 2.2 in GB50028-1993. Fluctuation range
0. 75~~1. 5 b amount
0.75~1. 5p amount
±0.5kPa
Appendix D
(standard appendix)
Quality of burning appliances
Product name
Serial number
2
3
Test items
Fire| |tt||Flame
Stable
Stable
Sex
Smoke

ridge
化||tt ||Carbon
Containing
Quantity
Tempering
Turn off the flame
Off the flame
Stove
Rack||tt ||Form
Heat
Water
Air tightness
Smoke
Tao
Hu
Form||tt ||Model
Production unit
Performance requirements
After the main fire burner is lit for 20 minutes, visually check whether the fire melt has tempered. After the main fire burner is lit for 15 seconds, visually check whether each fire hole is present. After 15 seconds of igniting the main fire burner in a cold flame state, it is visually inspected that one-third of the flame hole in a single burner has left the flame
It should comply with national standards within one year from the date of sale. It should not be greater than 0.14% from the date of sale for more than one year. It should comply with national standards within one year. The date of sale should not exceed 0.14% for more than one year. It should comply with national standards within one year. 0.07L/h Note: For details on the meaning of test temperament conditions, please refer to GB/T16411. Production date
Judgment conclusion
Test temperament conditions
2-3
3-1
3-3
3-1| |tt||0-2
0-2
0-2
air
Conclusion
807
5kPa
Appendix D
(standard appendix)
Quality of burning appliances
Product name
Serial number
2
3
Experimental Project
Fire
Flame
Stable
Stable
Smoke
Medium
ridge
chemical
carbon
containing
amount
tempering
flame out

Stove
Discharge
Type
Hot
Water
Air tightness
Smoke

hu
Type
Model
Production Unit
Performance Requirements
After the main fire burner is lit for 20 minutes, visually check whether the fire melt has tempered After 15 seconds of igniting the main fire burner, visually check whether there is a flame in each flame hole. After 15 seconds of cold lighting of the main fire burner, visually check that one-third of the flame holes of a single burner are out of flame
It should comply with national standards within one year from the date of sale. The date of sale shall not exceed 0.14% within one year. The date of sale shall comply with national standards within one year. The date of sale shall not exceed 0.14% within one year. The date of sale shall comply with national standards within one year. The date of sale shall not exceed 0.14% within one year. The date of sale shall not exceed 0.14% within one year. The leakage volume of the 0.28% burning appliance inlet should be less than 0.07L/h under the air pressure of 4.2kPa. Note: For details of the meaning of the test temperament conditions, please refer to GB/T16411. Production date
Judgment conclusion
Test temperament conditions
2-3
3-1
3-3
3-1| |tt||0-2
0-2
0-2
air
Conclusion
807
5kPa
Appendix D
(standard appendix)
Quality of burning appliances
Product name
Serial number
2
3
Experimental Project
Fire
Flame
Stable
Stable
Smoke
Medium
ridge
chemical
carbon
containing
amount
tempering
flame out

Stove
Discharge
Type
Hot
Water
Air tightness
Smoke
| |tt | After 15 seconds of igniting the main fire burner, visually check whether there is a flame in each flame hole. After 15 seconds of cold lighting of the main fire burner, visually check that one-third of the flame holes of a single burner are out of flame
It should comply with national standards within one year from the date of sale. The date of sale shall not exceed 0.14% within one year. The date of sale shall comply with national standards within one year. The date of sale shall not exceed 0.14% within one year. The date of sale shall comply with national standards within one year. The date of sale shall not exceed 0.14% within one year. The date of sale shall not exceed 0.14% within one year. The leakage volume of the 0.28% burning appliance inlet should be less than 0.07L/h under the air pressure of 4.2kPa. Note: For details of the meaning of the test temperament conditions, please refer to GB/T16411. Production date
Judgment conclusion
Test temperament conditions
2-3
3-1
3-3
3-1| |tt||0-2
0-2
0-2
air
Conclusion
807
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.