title>JB/T 7658.15-1995 Ammonia filter for ammonia refrigeration equipment - JB/T 7658.15-1995 - Chinese standardNet - bzxz.net
Home > JB > JB/T 7658.15-1995 Ammonia filter for ammonia refrigeration equipment
JB/T 7658.15-1995 Ammonia filter for ammonia refrigeration equipment

Basic Information

Standard ID: JB/T 7658.15-1995

Standard Name: Ammonia filter for ammonia refrigeration equipment

Chinese Name: 氨制冷装置用氨气过滤器

Standard category:Machinery Industry Standard (JB)

state:Abolished

Date of Release1995-06-16

Date of Implementation:1996-07-01

Date of Expiration:2007-04-01

standard classification number

Standard Classification Number:Machinery>>General Machinery and Equipment>>J73 Refrigeration Equipment

associated standards

alternative situation:Replaces JB 455-86; JB 4346-86; replaced by JB/T 7658.15-2006

Publication information

publishing house:Mechanical Industry Press

Publication date:1996-07-01

other information

Focal point unit:Hefei General Machinery Research Institute

Introduction to standards:

This standard replaces JB 455-86 and JB 4346-86. JB/T 7658.15-1995 Ammonia filter for ammonia refrigeration equipment JB/T7658.15-1995 Standard download decompression password: www.bzxz.net

Some standard content:

Mechanical Industry Standard of the People's Republic of China
Ammonia Filters for Ammonia Refrigeration Devices
1 Subject Content and Scope of Application
JB/T7658.15—95
Replaces B4346-86
JB 455--86
This standard specifies the terminology, product classification, technical requirements, test methods, inspection rules, marking, packaging and transportation of ammonia filters for ammonia refrigeration devices (hereinafter referred to as filters). This standard applies to ammonia filters for ammonia refrigeration devices. 2 Reference standards
GB197 Ordinary thread tolerances and fits (diameter 1~355mm) GB/T1804--General tolerances Unindicated tolerances for linear dimensions GB5330 Industrial metal wire woven square hole screen GB/T13306 Signs
JB/T6917 Pressure vessels for refrigeration equipment
3 Terms
3.1 Ammonia filter
In the ammonia refrigeration system, it is installed on the suction pipe of the ammonia compressor to filter rust, impurities, etc. in the ammonia to ensure the normal operation of the compressor.
4 Product classification
4.1 Type
According to its structural type, the filter is a right-angle steel wire filter type. 4.2 Model
4.2.1 Model representation method
The model of the filter consists of uppercase Chinese pinyin letters and Arabic numerals (hereinafter referred to as numbers). The method of indicating the model is as follows:
Retrofit number: indicated by numbers, the first design product omits the nominal diameter of the pipe: indicated by numbers, mm filter code
4.2.2 Model example
QG80-1: indicates that the nominal diameter of the pipe is 80mm, the first retrofit filter. 4.3 Basic parameters
The nominal diameter of the pipe of the filter shall comply with the provisions of Table 1. Approved by the Ministry of Machinery Industry of the People's Republic of China on June 16, 1995 and implemented on July 1, 1996
4.4 Design conditions
Design pressure: 1.4MPa;
b. Design temperature: 38℃.
5 Technical requirements
5.1 General requirements
JB/T 7658.15—95
The filter shall comply with the provisions of this standard and be manufactured according to the drawings and technical documents approved by the prescribed procedures. It can also be manufactured according to the agreement between the user and the manufacturer.
5.2 Materials
5.2.1 The materials of the main pressure-bearing components of the filter shall have a material certificate. 5.2.2 The materials used for the filter shall comply with the provisions of JB/T6917. 5.3 Filter mesh
5.3.1 The filter shall be equipped with a metal filter mesh that is not corroded by the refrigerant and has sufficient flow area. The filter mesh should have no less than 50 holes per 25.4mm.
5.3.2 The filter mesh of the filter shall comply with the provisions of GB5330. 5.4 Seamless steel pipes and steel plates
The surface of the seamless steel pipes and steel plates used for the filter shall not have defects such as pitting, rust, and cracks. 5.5 Head
The head of the filter should be made of a whole piece of steel plate by rolling. It should not be spliced. 5.6 Flange
The flange surface of the filter should be perpendicular to the main axis of the pipe or cylinder, and its deviation should not exceed 1/100 of the flange outer diameter. 5.7 Thread
The various thread precisions are manufactured according to the 6th grade precision specified in GB197. 5.8 Unnoted tolerance
The unnoted tolerance of the linear dimensions of the cutting surface of the filter shall be in accordance with the tolerance grade m (medium grade) specified in GB/T1804, and the unnoted tolerance of the linear dimensions of the non-cutting surface shall be in accordance with the tolerance grade c (rough grade) specified in GB/T1804. 5.9 Pressure resistance and airtightness requirements
5.9.1 The filter should be subjected to pressure resistance test. The hydraulic pressure resistance test pressure is 1.25 times the design pressure, and the gas pressure resistance test pressure is 1.15 times the design pressure. The pressure holding time is not less than 10 minutes, and there should be no leakage. 5.9.2 The airtightness test can be carried out only after the filter passes the hydraulic test. The test pressure is equal to the design pressure, and the pressure holding time is not less than 10 minutes. There should be no leakage. The filter that has been tested for air pressure and passed the inspection does not need to be tested for airtightness. 5.10 Appearance quality
The filter should be beautiful and generous, the surface should be smooth and flat, the outer surface should be painted, the paint color should be harmonious and durable, and there should be no defects that affect the appearance.
5.11 Cleanliness
The inside of the filter should be clean, and the impurity content in the part in contact with the refrigerant should not exceed 800mg/m2. 5.12 Flow direction mark
The filter should be marked with a clear flow direction arrow. 5.13 Completeness
JB/T 7658.15.-.95
The filter supplied as a set should also include a set assembly flange. 5.14 Warranty periodwwW.bzxz.Net
If the user complies with the provisions of the product manual, within 18 months from the date of manufacture and delivery, if the filter is damaged or fails to work properly due to poor manufacturing, the manufacturer shall replace or repair it free of charge. 6 Test methods
6.1 Pressure test and airtightness test
The pressure and airtightness test methods of the filter shall comply with the provisions of JB/T6917. 7 Inspection rules
7.1 General requirements
The filter shall be inspected by the technical inspection department of the manufacturer in accordance with this standard and technical documents, and can only be shipped after passing the inspection. 7.2 Inspection items
Check the material report of the main pressure-bearing components; check the processing quality;
pressure and airtightness test;
check the contents of the label;
check the completeness of the product according to the factory documents. 8 Marking, packaging and transportation
8.1 Marking
8.1.1 Label
The filter should be fixed with a label on a clear and flat position. The label should comply with the provisions of GB/T13306. The content marked on the label can refer to the provisions of JB/T6917.
8.1.2 Factory documents
The factory documents of the filter can refer to the provisions of JB/T6917. 8.2 Packaging and transportation
8.2.1 Before packing, the taper pipe joint should be coated with anti-rust grease and sealed with a screw plug. The flange should be tightened with bolts, and the sealing surface should be coated with anti-rust grease and sealed with a blind plate.
8.2.2 If the filter is supplied as a set with other ammonia refrigeration equipment, it can be packed and transported together with other equipment without separate packaging. If it is supplied separately, it should be properly wrapped.
Additional Notes:
This standard was proposed and managed by the Hefei General Machinery Research Institute of the Ministry of Machinery Industry. This standard was drafted by Wuhan New World Refrigeration Industry Co., Ltd. and Dalian Refrigeration Co., Ltd. The main drafters of this standard are: Hu Zengwu, Sun Zhengguo, Ha Hongbo, Li Muzhen. This standard was first issued in January 1964 and revised for the first time in December 1986. 1443
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.