title>HG 3229-1989 Flat plate vulcanizing press test method - HG 3229-1989 - Chinese standardNet - bzxz.net
Home > HG > HG 3229-1989 Flat plate vulcanizing press test method
HG 3229-1989 Flat plate vulcanizing press test method

Basic Information

Standard ID: HG 3229-1989

Standard Name: Flat plate vulcanizing press test method

Chinese Name: 平板硫化机检测方法

Standard category:Chemical industry standards (HG)

state:in force

standard classification number

associated standards

alternative situation:ZB G95011-88

Publication information

other information

Introduction to standards:

HG 3229-1989 Flatbed vulcanizing press test method HG3229-1989 standard download decompression password: www.bzxz.net

Some standard content:

Professional Standard of the People's Republic of China
1G32298
Daylight press-Testing and measuring methodsPublished on 1989-02-28
Implemented on 1989-05-01
Published by the Ministry of Chemical Industry of the People's Republic of ChinaProfessional Standard of the People's Republic of China
Daylight press -Testing and
measuring methods
Subject Content and Scope of Application
This standard specifies the testing methods for the main items of the plate vulcanizer. This standard is applicable to the testing of hydraulic plate vulcanizers. This standard should be used in conjunction with the product standard GB10480 "Plate Vulcanizer". Main accuracy and performance tests (see Table 1) 2
Test items
Surface
Roughness
Nominal mold
Test method
Test at any
distance from the edges of the hot plate.
(1) Measure with a stylus surface roughness measuring instrument,
(2) Compare and judge with a surface roughness comparison sample.
Both methods have equal validitybzxz.net
Place a mold or a rubber sheet of appropriate thickness between each layer of hot plate to prevent direct contact with the working surface of the hot plate.
Pressure at the maximum working pressure for 5 minutes and record the pressure gauge reading. Use the following formula to calculate the nominal clamping force: P=10-4.P,·Fn
Wherein: P is the nominal clamping force, MN; P—the pressure gauge reading, MPa; F—the area of ​​the hydraulic pressure acting on the plunger, cm2; Number of hydraulic cylinders: The thickness of the hot plate approved by the Ministry of Chemical Industry of the People's Republic of China on February 28, 1989: One measuring point
ZBG95011-89
Testing tools
Stylus-type surface
Roughness measurement
Surface roughness
Comparison sample
Pressure gauge
1989-05-01Implementation
Testing items
Opening and closing of hot plate
ZBG95011--89
Continued Table 1
Testing methods
When the hot plate is running to a stable state, put it in a completely closed position. Start to press the "open" button and use a stopwatch to record the time. When the hot plate drops to the maximum open position and stops moving, stop the timer and record the time. And use a steel ruler to measure the distance of the opening.
When the hot plate is in the maximum open position, start pressing the "Close" button and use a stopwatch to time. When the hot plate is completely closed and stops moving, stop the timer to record the time and measure the closing distance.
Repeat the measurement three times in a row, calculate separately, and take the smaller value as the opening and closing speed of the hot plate.
Hot-steam heated or electrically heated flat vulcanizer: High working temperature Use saturated steam with a force of 1MPa or connect the hot plate working
power supply to heat the hot plate to a stable state. According to the measurement range L shown in the figure, use a point thermometer of the corresponding range to measure near the center line.
L<1000mm, measure one point,
1000mmL<3000mm, measure point
3000mm
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.