This standard specifies some important terms for power fittings. This standard is applicable to the formulation of power fittings standards, the compilation and translation of professional literature, teaching materials and books and periodicals, and can also be used as a reference in other fields related to power fittings. GB/T 5075-2001 Power Fittings Terminology GB/T5075-2001 Standard download decompression password: www.bzxz.net
Some standard content:
ICS.29.240.20 National Standard of the People's Republic of China GB/T5075—2001 Terminology for electric power fittings2001-11-02Promulgated General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China 2002-04-01Implementation GB/T5075—2001 This standard is revised according to the national standard formulation and revision plan of the National Quality and Technical Supervision Commission. GB/T2900.51—1998 "Electrical Terminology Overhead Lines" was referenced when revising the original standard. There are many items in the original standard, and this standard has been merged. A total of 75 items are listed in this standard, of which 25 are newly added. Appendix A and Appendix B of this standard are both prompt appendices. This standard was proposed by the former Ministry of Electric Power Industry. This standard is under the jurisdiction of the National Technical Committee for Standardization of Overhead Lines (Electric Power Fittings). This standard was drafted by the Electric Power Construction Research Institute of the State Power Corporation. The main drafters of this standard are: Bo Tong, Xu Naiguan, Dong Ji, You Chuanyong. This standard is interpreted by the National Technical Committee for Standardization of Overhead Lines (Electric Power Fittings). 1 Scope National Standard of the People's Republic of China Terminology for electric power fittings Terminology for electric power fittings This standard specifies some important terms for electric power fittings. GB/T5075-2001 Replaces GB/T5075-1985 This standard is applicable to the formulation of electric power fittings standards, the compilation and translation of professional literature, teaching materials and books and periodicals, and can also be used as a reference in other fields related to electric power fittings. 2 Glossary 2.1 General 2.1.1 Electric power fittings are metal accessories that connect and combine various devices in the power system and play a role in transmitting mechanical loads, electrical loads and certain protective functions. 2.1.2 Suspension clamps are fittings that hang the conductor on the suspension string group or pole tower. 2.1.3 Tension clamps, strain clamps, dead-end clamps are fittings used to fix the conductor to withstand the conductor tension and hang the conductor on the tension string group or pole tower. 2.1.4 Link fittings, insulator set fittings are fittings used to connect insulators, suspension clamps, tension clamps and protective fittings into suspension or tension groups. 2.1.5 Tension joints, splices are fittings used to connect two conductors and can meet the mechanical and electrical performance requirements of the conductors. 2.1.6# Partial tension fittings are used to connect wires or terminals of electrical equipment, and are mainly used to transfer electrical loads. 2.1.7 Protective fittings protective fittings Fittings used to protect the electrical or mechanical properties of various electrical devices or fittings themselves. 2.1.8 Bus-bar fittings are fittings used to fix, suspend and support power distribution equipment. 2.1.9 CTAMP Fittings or parts of fittings used to fix on or fix wires. 2.1.10Failure load failure load The load that causes the failure of the fitting under specified test conditions. 2.1.11 Nominal failure load specified failure load is the minimum failure load value of the fitting specified by the buyer or announced by the supplier. Damage load damageload The maximum load that the fittings can withstand without permanent deformation. Approved by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China on November 2, 2001, and implemented on April 1, 2002 2.1.13 Slip GB/T5075—2001 When a fitting that fastens the conductor in any way causes a relative displacement between the conductor and the fitting after the load is applied, so that the test load cannot continue to rise, this phenomenon is called slip. 2.1.14 Grip strength, holding strength The load that a fitting that fastens the conductor in any way can withstand without slipping. 2.1.15 Insulator string Insulator string combines multiple insulators to provide flexible support for the conductor. Insulator strings mainly withstand tensile forces. 2.1.16 Insulator set, insulator assembly One or more insulator strings are combined into a whole, and are equipped with all the hardware required for line operation. One end is flexibly fixed to the pole tower with hardware, and the other end can suspend or support the conductor. Suspension insulator set 2.1.17 An insulator set used to suspend a single conductor or split conductor and mainly bear its weight. 2.1.18 Tension insulator set An insulator set used to bear the tension of a single conductor or split conductor. 2.1.19 Maximum exit angle maximum xitangle The maximum tangent angle allowed by the hull wire groove curve at the point where the conductor is out of contact with the suspension wire clamp. 2.1.20 Minimum exit angle minimum xitangle The minimum tangent angle allowed by the hull wire groove curve at the point where the conductor is out of contact with the vertical wire clamp. 2.1.21 Compression-type fittingsCompression-type fittings are fittings that require pressure to produce permanent deformation in all or part of the fittings to complete the installation work. This fitting cannot be used repeatedly. 2.1.22Non-compression type fittings are fittings that do not produce permanent deformation in any part of the fittings during installation compared to compression-type fittings. This type of fittings can be used repeatedly. 2.1.23Temperature rise temperaturerise The difference between the temperature at a certain point on the fitting component that conducts current and the specified reference temperature. 2.2Product categories 2.2.1Linkeye Connection fittings with both ends being ring-shaped connectors. 2.2.2 Clevis, tongueplate A plate-shaped (single or double-piece) connector assembled with bolts: or a connection fitting with both ends being plate-shaped connectors. 2.2.3Ball A connecting piece in the shape of a club (the matching connecting piece is a socket). Socket A connecting piece in the shape of a socket (the matching connecting piece is a ball). 2.2.5Hook A connecting piece in the shape of a hook. 2.2.6U-Shackle A "U"-shaped fitting composed of a shackle and a plate connecting piece at both ends. 2.2.7U-bolt A "U"-shaped fitting composed of a shackle and a threaded rod at both ends for connection with a pole tower. 2.2.8U-clevis,elevishingeA "U"-shaped fitting bent from a strip of steel plate, one end of which is a plate connecting piece and the other end is equipped with a bolt that bears shear force, used to connect with a pole 2 tower. 2.2.9 Yokeplate GB/T5075-2001 A plate-shaped connection fitting that assembles multiple force-bearing branches into an integral whole. 2.2.10 Towingplate A connection fitting with hanging plate connectors at both ends and construction towing holes. Adjustingplate A plate-shaped connection fitting with adjustable connection length. 2.2.12 2 Turnbuckle A connection fitting with left-hand and right-hand threads at both ends to adjust the connection length. 2.2.13 Hanger A connection fitting that supports the lightning conductor on the pole and replaces the crossarm. 2.2.14 Dropper Connecting fittings used to reduce the height of the suspension point of the suspended insulator string on the tower transverse torsion. 2.2.15 5 Splicing sleeve, mid-span tension joint A round or circular splicing fitting used to connect conductors and maintain the electrical and mechanical properties of the conductors. 2.2.16 Repair sleeve A tubular fitting used to repair damaged conductors to restore their electrical and mechanical properties. Preformed helical fitting 2.2.17 A fitting used to wrap a preformed spiral strip around a conductor or ground wire to withstand mechanical or electrical loads. 2.2.18 Parallel groove clamp A contact fitting used to transfer electrical loads between two parallel conductors. Jumper clamp jumperclamp.jumperlug2.2.19 Contact fittings used to connect jumpers to transfer electrical loads, 2.2.20 Vibration damper, damper is hung on the conductor or ground wire to suppress or reduce breeze vibration. Grading ring grading ring A circular fitting that improves the voltage distribution on the insulator string. 2.2.22 Shielding ring shielding ring A circular fitting that prevents other fittings or components within the shielding range from corona. 2.2.23 Arcing horn An angular fitting that prevents arcs from flashing along the surface of an insulator. Arcing ring arcing ring A circular fitting that prevents arcs from flashing along the surface of an insulator. 2.2.25 Spacer A fitting that keeps the sub-conductors of a split conductor in a certain geometric arrangement. 2.2.26Armor rods A metal wire that is spirally wound around the conductor at the suspension point before the suspension clamp is installed to increase the rigidity and vibration resistance of the conductor. 2.2.27Aluminum armour tapeAluminum tape that is wound around the aluminum conductor to protect its surface from wear. 2.2.28Counter weight, downweightA heavy object hung at the lower end of the suspension clamp to increase the vertical load of the clamp. 2.2.29 Guy clip A saddle-shaped assembly that fixes the end of the steel wire. 3 2.2.30 Heart-shaped ring thimble GB/T5075—2001 Pad used for winding steel strands or wire ropes. Equipment clamp terminal connector Metal fittings used to connect wires to electrical equipment terminals to transfer electrical loads. 2.2.32 T-type clamp T-connector Metal fittings used to connect wires to branch lines to transfer electrical loads. Copper to aluminum adapter board 2.2.33 A contact plate that connects copper terminals to aluminum terminals to prevent overcurrent corrosion. Busbar fixing hardware bus-bar support clamp 2.2.34 Metal fittings used to fix and suspend busbars. 2.2.35 Busbar spacer bus-harseparator Support parts used to maintain a certain distance between busbars. 2.2.36 Busbar expansion joint bus-bar expansion joint is a flexible connector used to compensate for the deformation of the busbar due to heat and vibration. 2.2.37 Corona ball, cap A spherical (semi-circular) component used to prevent corona from being generated at the terminal of the tube busbar. 2.2.38 Night warning light night warning light A device attached to the wire that emits light by virtue of the capacitance of the charged wire. 2.2.39 Aviation warning sign aircraft warning marker is a warning device attached to the wire or ground wire and visible during the day. 2.3 Test method type 2.3.1 Visual inspection visual inspection of the appearance quality of the hardware mainly by visual observation. 2.3.2 Type test typetest Tests conducted on hardware products designed and manufactured according to certain technical conditions to verify whether their design characteristics meet the specified standards. They are usually conducted once and repeated only when the design or material changes. 2.3.3 Sampling test samplingtest A test conducted by randomly extracting a certain number of products from a batch of products produced under the same conditions to verify the material quality and process quality. Routine test routinetest Tests conducted on hardware one by one using appropriate methods to eliminate defective products. 2.3.5 Regular test regular.test Tests conducted according to the specified cycle or after a certain period of suspension of production to check whether the molds and positioning devices used in the manufacturing process are deformed, worn or displaced, and whether the galvanizing quality meets the standards. 2.3.6 Vibration test vibration test A test conducted under specified test conditions to measure the dynamic characteristics of anti-vibration hardware. Fatigue test fatiguetest Under specified vibration conditions, the vibration tolerance performance test of the hardware is tested. 2.3.8 Resistance test resistance test The test of connecting the hardware to the electrical circuit to measure its resistance value. 2.3.9 Heat cycle test heat cycle test The test of simulating the long-term operation of the test piece under the specified current load and temperature rise. 2.3.10 Radio interference test radiointerferencetest4 GB/T5075—2001 The test of measuring the radio interference level of the test piece under the operating voltage. 2.3.11 Corona test Under the actual use state, the test of measuring the visible corona phenomenon of the test piece due to the effect of the electric field. 2.3.12 Hot galvanizing test hot galvanizing test The inspection of the quality of hot-dip galvanizing on the surface of the hardware, including the test of the weight (or thickness) of the zinc layer, the uniformity of the zinc layer and the adhesion of the zinc layer. Bending resistance testBending resistance testUnder specified conditions, the test piece is tested for its bearing capacity under bending load. Protective fittings Nominal breaking load Parallel groove clamp Sampling test… Electric fittings Corona test Resistance test Periodic test Vibration damper Non-compression fittings ...o...o. Terminal ball Hanging ring· Aviation warning sign Bar guard Turnbuckle screw Spacer Contact fittings Connecting pipe Connecting fittings Insulator string GB/T5075-2001 Appendix A (Appendix of suggestion) Chinese index Insulator string groupwwW.bzxz.Net Grading ring Bending test Routine test Joining plate… Connecting fittings, Aluminum clad tape Busbar fixing fittings Busbar spacer||tt| |Busbar hardware Busbar expansion joint Strain insulator string Strain clamp Fatigue test Shielding ring Destruction load Traction plate Ball head, Hot-dip galvanizing test Thermal cycle test· Equipment clamp Damage load Jumper clamp Adjustment plate Copper-aluminum transition plate Appearance inspection: Radio interference test Wire clip Heart-shaped ring Type test T-type clamp U-type hanging plate adjusting plate aircraft warning marker aluminumarmourtape arcing horn arcing ring armourrods bending resistance test bus-bar expansion joint ....bus-harfitting bus-bar separator bus-bar support clamp GB/T5075-2001 U-shaped hanging ring U-shaped screw .2.2.29 Repair tube Suspension insulator string Suspension wire clamp Compression type hardware Extension frame Night warning light Arc starter ring Pre-twisted hardware Arc starter angle Vibration test Maximum exit angle Minimum exit angle Appendix B (Suggestive appendix) English index ..2.2.23 .2.1.8 clevis clevis hinge crmpression-typefitting …2.2.24 copper to aluminum adapter board ... 2. 2. 33corona ball corona test counter weight damage load damper dead-end clamp down weight dropper electric power fittings failure load fatigue test grading ring grip strength guyelip hanger heat cycle test holding strength hot galvanizing test, insulator assembly insulator set insulator set fitting insulator string | |tt | clamp partial tension fitting preformed helical fitting protective fitting radio interference test regulartest repair sleeve resistance test routine test sampling test shackle shielding ring | joint,splice terminal connector thimble ... tongue towing plate turn buckle typetest U-bolt .2.2.17 .+... U-clevis vibration dampcr vibration test GB/T5075-2001 visual inspection yoke plate GB/T5075-2001 People's Republic of China National standard Terms and terms of power fittings GB/T5075--2001 Published by China Standards Press No. 16, Sanlihebei Street, Fuxingmenwai, Beijing Postal code: 100045 Tel: 6852394668517548|| tt||Printed by China Standard Press, Qinhuangdao Printing Factory, Xinhua Bookstore, Beijing Distribution Office, Xinhua Bookstores in various regions* Format: 880×12301/16 Sheet 1 Word Count: 18,000 Words First Edition: March 2002 First Printing: March 2002 Print Quantity: 1-1500 Website: bzcbs.com Copyright reserved Infringements must be investigated Report Phone: (010)6853353329 Repair tube Suspension insulator string Suspension wire clamp Compression-type fittings Extension frame Night warning light Arc-starting ring Pretwisted fittings Arc-starting angle Vibration test Maximum outlet angle Minimum outlet angle Appendix B (Suggestive appendix) English index ..2.2.23 .2.1.8 clevis clevis hinge crmpression-type fitting …2.2.24 copper to aluminum adapter board ... 2. 2. 33corona ball corona test counter weight damage load damper dead-end clamp down weight dropper electric power fittings failure load fatigue test grading ring grip strength guyelip hanger heat cycle test holding strength hot galvanizing test, insulator assembly insulator set insulator set fitting insulator string jumperclamp jumperlug linkfitting maximum exit angle mid-span tension joint minimum exit angle night warning light non-compression type fitting8 GB/T50752001 parallel groove clamp partial tension fitting preformed helical fitting protective fitting radio interference test regulartest repair sleeve resistance test routine test sampling test shackle shielding ring socket spacer specified failure load splice sleeve strain clamp suspension clamp suspension insulator set T-connector temperature rise tension clamp tension insulator set tension joint,splice terminal connector thimble ... tongue towing plate turn buckle typetest U-bolt .2.2.17 .+...... U-clevis vibration dampcr vibration test GB/T5075-2001 visual inspection yoke plate GB/T5075-2001 People's Republic of China National Standard Terms and Terms of Power Fittings GB/T5075--2001 Published by China Standards Press No. 16, Sanlihebei Street, Fuxingmenwai, Beijing Postal Code: 100045 Tel: 6852394668517548|| tt||Printed by China Standard Press, Qinhuangdao Printing Factory, Xinhua Bookstore, Beijing Distribution Office, Xinhua Bookstores in various regions* Format: 880×12301/16 Sheet 1 Word Count: 18,000 Words First Edition: March 2002 First Printing: March 2002 Print Quantity: 1-1500 Website: bzcbs.com Copyright reserved Infringements must be investigated Report Phone: (010)6853353329 Repair tube Suspension insulator string Suspension wire clamp Compression-type fittings Extension frame Night warning light Arc-starting ring Pretwisted fittings Arc-starting angle Vibration test Maximum outlet angle Minimum outlet angle Appendix B (Suggestive appendix) English index ..2.2.23 .2.1.8 clevis clevis hinge crmpression-type fitting …2.2.24 copper to aluminum adapter board ... 2. 2. 33corona ball corona test counter weight damage load damper dead-end clamp down weight dropper electric power fittings failure load fatigue test grading ring grip strength guyelip hanger heat cycle test holding strength hot galvanizing test, insulator assembly insulator set insulator set fitting insulator string jumperclamp jumperlug linkfitting maximum exit angle mid-span tension joint minimum exit angle night warning light non-compression type fitting8 GB/T50752001 parallel groove clamp partial tension fitting preformed helical fitting protective fitting radio interference test regulartest repair sleeve resistance test routine test sampling test shackle shielding ring socket spacer specified failure load splice sleeve strain clamp suspension clamp suspension insulator set T-connector temperature rise tension clamp tension insulator set tension joint,splice terminal connector thimble ... tongue towing plate turn buckle typetest U-bolt .2.2.17 .+...... U-clevis vibration dampcr vibration test GB/T5075-2001 visual inspection yoke plate GB/T5075-2001 People's Republic of China National Standard Terms and Terms of Power Fittings GB/T5075--2001 Published by China Standards Press No. 16, Sanlihebei Street, Fuxingmenwai, Beijing Postal Code: 100045 Tel: 6852394668517548|| tt||Printed by China Standard Press, Qinhuangdao Printing Factory, Xinhua Bookstore, Beijing Distribution Office, Xinhua Bookstores in various regions* Format: 880×12301/16 Sheet 1 Word Count: 18,000 Words First Edition: March 2002 First Printing: March 2002 Print Quantity: 1-1500 Website: bzcbs.com Copyright reserved Infringements must be investigated Report Phone: (010)68533533 insulator assembly insulator set insulator set fitting insulator string jumperclamp jumperlug linkfitting maximum exit angle mid-span tension joint minimum exit angle night warning light non-compression type fitting8 GB/T50752001 parallel groove clamp partial tension fitting preformed helical fitting protective fitting radio interference test regulartest repair sleeve resistance test routine test sampling test shackle shielding ring socket spacer specified failure load splice sleeve strain clamp suspension clamp suspension insulator set T-connector temperature rise tension clamp tension insulator set tension joint,splice terminal connector thimble ... tongue towing plate turn buckle typetest U-bolt .2.2.17 .+...... U-clevis vibration dampcr vibration test GB/T5075-2001 visual inspection yoke plate GB/T5075-2001 People's Republic of China National Standard Terms and Terms of Power Fittings GB/T5075--2001 Published by China Standards Press No. 16, Sanlihebei Street, Fuxingmenwai, Beijing Postal Code: 100045 Tel: 6852394668517548|| tt||Printed by China Standard Press, Qinhuangdao Printing Factory, Xinhua Bookstore, Beijing Distribution Office, Xinhua Bookstores in various regions* Format: 880×12301/16 Sheet 1 Word Count: 18,000 Words First Edition: March 2002 First Printing: March 2002 Print Quantity: 1-1500 Website: bzcbs.com Copyright reserved Infringements must be investigated Report Phone: (010)68533533 insulator assembly insulator set insulator set fitting insulator string jumperclamp jumperlug linkfitting maximum exit angle mid-span tension joint minimum exit angle night warning light non-compression type fitting8 GB/T50752001 parallel groove clamp partial tension fitting preformed helical fitting protective fitting radio interference test regulartest repair sleeve resistance test routine test sampling test shackle shielding ring socket spacer specified failure load splice sleeve strain clamp suspension clamp suspension insulator set T-connector temperature rise tension clamp tension insulator set tension joint,splice terminal connector thimble ... tongue towing plate turn buckle typetest U-bolt .2.2.17 .+...... U-clevis vibration dampcr vibration test GB/T5075-2001 visual inspection yoke plate GB/T5075-2001 People's Republic of China National Standard Terms and Terms of Power Fittings GB/T5075--2001 Published by China Standards Press No. 16, Sanlihebei Street, Fuxingmenwai, Beijing Postal Code: 100045 Tel: 6852394668517548|| tt||Printed by China Standard Press, Qinhuangdao Printing Factory, Xinhua Bookstore, Beijing Distribution Office, Xinhua Bookstores in various regions* Format: 880×12301/16 Sheet 1 Word Count: 18,000 Words First Edition: March 2002 First Printing: March 2002 Print Quantity: 1-1500 Website: bzcbs.com Copyright reserved Infringements must be investigated Report Phone: (010)68533533 Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.