title>JB 8735.3-1998 Rubber insulated flexible cords and flexible cables of rated voltage 450/750V and below Part 3: Rubber insulated braided flexible wires - JB 8735.3-1998 - Chinese standardNet - bzxz.net
Home > JB > JB 8735.3-1998 Rubber insulated flexible cords and flexible cables of rated voltage 450/750V and below Part 3: Rubber insulated braided flexible wires
JB 8735.3-1998 Rubber insulated flexible cords and flexible cables of rated voltage 450/750V and below Part 3: Rubber insulated braided flexible wires
Basic Information
Standard ID:
JB 8735.3-1998
Standard Name: Rubber insulated flexible cords and flexible cables of rated voltage 450/750V and below Part 3: Rubber insulated braided flexible wires
JB/T 8735.3-1998 This standard is a supplement to GB 5023.-~5023.7-1997 "Polyvinyl chloride insulated cables with rated voltages of 450/750V and below". The main technical parameters, basic test conditions and performance indicators of the products in this standard are in line with the provisions of GB 5023.1~5023.7-1997. This standard specifies the models, specifications, technical requirements and inspections of rubber insulated braided flexible wires. This standard is applicable to rubber insulated braided flexible wires for indoor lighting fixtures and household appliances with an AC rated voltage U0/U of 300/300V and below. In addition to meeting the technical requirements specified in this standard, cables should also meet the requirements of JB 8735.1. JB 8735.3-1998 Rubber insulated flexible cords and flexible cables with rated voltage up to and including 450/750V Part 3: Rubber insulated braided flexible wires JB8735.3-1998 Standard download decompression password: www.bzxz.net
Some standard content:
JB8735.1~8735.3—1998 This standard is a supplement to GB5013.1~5013.7—1997 Rubber insulated cables with rated voltages of 450/750V and below. The products covered by this standard were originally specified in GB5013.2-85 and GB3958-83, but GB5013.1-5013.3-85, GB5013.4-87 and GB3958-83 have been revised. The revised GB5013.1~5013.7—1997 is equivalent to using Parts 1 to 7 of the IEC245 standard. Therefore, some products have not been included despite the demand in the domestic market and export trade. The main technical parameters, basic test conditions and performance indicators of the products in this standard are in line with the provisions of GB5013.1~5013.7--1997. This standard is proposed and managed by the National Wire and Cable Standardization Technical Committee. The drafting unit of this standard is Shanghai Cable Research Institute, Ministry of Machinery Industry. The main drafters of this standard are Zhu Hao, Zeng Quan and Zhu Yizhen. 1 Scope Machinery Industry Standard of the People's Republic of China Rubber insulated cords and flexible cables of rated voltages up to and including 450/750V Part 3: Rubber Insulated braided cords This standard specifies the models, specifications, technical requirements and inspections of rubber insulated braided cords. JB 8735. 3—1998 This standard is applicable to rubber insulated braided flexible cords for indoor lighting fixtures and household appliances with an AC rated voltage U./U of 300/300V and below. In addition to meeting the technical requirements specified in this standard, the cables shall also meet the requirements of JB8735.1. 2 Reference standards The following standards contain clauses that constitute the clauses of this standard by reference in this standard. At the time of publication of the standard, the versions shown are valid. All standards will be revised, and parties using this standard should explore the possibility of using the latest versions of the following standards. GB/T2951-1997 General test methods for cable insulation and sheath materials (idtIEC811-1993) GB5013.2-1997 Test methods for rubber insulated cables with rated voltages of 450/750V and below (idtIEC245-2--1994) JB8735.1-1998 3 Usage characteristics Rubber insulated cords and cables with rated voltages of 450/750V and below Part 1: General provisions 3.1 The rated voltage U./U is 300/300V. 3.2 The long-term allowable operating temperature of the flexible wire should not exceed 60℃. 4 Model The model of the cable is shown in Table 1. Table 1 Model and name 5 Specification The cable specifications shall comply with the provisions of Tables 2 to 4. Approved by the Ministry of Machinery Industry on 1998-05-28 Rubber insulated braided flexible wire Rubber insulated braided twisted pair flexible wire Rubber insulated rubber protective layer total braided round flexible wire 1998-11-01 Implementation Nominal cross section Single wire in conductor Maximum diameter Insulation thickness Specified value JB8735.3-1998 Table 2RX type rubber insulated braided flexible wire Average outer diameter Note, for specifications of 0.75~1.5mm2, see 245IEC51 (RX) type braided flexible wire in GB5013.4. Table 3 RXS type braided twisted pair flexible wire Single wire in conductor Nominal cross section Nominal cross section 6 Technical requirements 6.1 Conductor Maximum diameter Single wire in conductor Maximum diameter Insulation thickness Specified value Insulation thickness Specified value Each braided insulated wire core Maximum average outer diameter Table 4 RXH type total braided round flexible wire Average outer diameter 6.1.1 The number and structure of conductor cores shall comply with the provisions of Table 2~4. 6.1.2 The single wire in the conductor may be tinned or not. 6.2 Insulation Conductor resistance at 20℃ Maximum value Tinned copper core Conductor resistance at 20℃ Tinned copper core Conductor resistance at 20℃ Maximum value Tinned copper coreWww.bzxZ.net JB 8735. 3—1998 6.2.1 The insulation shall be a rubber mixture with code IE1. If extrusion is not used, the insulation shall consist of at least two layers, and there shall be no delamination between the two layers of insulation. 6.2.2 The insulation thickness shall comply with the provisions of Tables 2 to 4. 6.2.3 The insulated core of two-core braided flexible wire shall be light blue or brown. 6.3 Twisting 6.3.1 The insulated cores of RX and RXH flexible wires shall be twisted into cables, and the gaps between the cables shall be filled with cotton yarn or other materials with equivalent softness to make them round. RXS type flexible wires shall be twisted after the insulated core is braided. 6.3.2 The cable pitch of RX type flexible wires shall not exceed 5.5 times the calculated value of the cable outer diameter, and the cable pitch of RXH and RXS type flexible wires shall not exceed 8 times the calculated value of the cable outer diameter. 6.3.3 The twisting direction shall be right-handed. 6.4 Protective layer 6.4.1 After the RXH type flexible wires are twisted into cables, a thin layer of rubber shall be extruded. The braid shall be half-embedded in the rubber protective layer. 6.4.2 The braid shall be made of filament regenerated fiber, waxed cotton yarn or other similar materials. 6.5 Overall dimensions The average outer diameter of the flexible wire shall comply with the provisions of Tables 2 to 4. 6.6 Origin marking The origin marking of rubber insulated braided flexible wires can be selected from the following two methods. 6.6.1 Use a single-color or multi-color marking line that has been registered and filed exclusively for the manufacturer. 6.6.2 The manufacturer’s name or trademark shall be printed on the surface of the insulated wire core. 7 Inspection Product inspection items, test types and test methods shall be in accordance with the provisions of Table 5. Table 5 Inspection Inspection items Electrical performance test Conductor resistance Finished cable 2000V voltage test Structural dimension inspection Structural inspection Insulation thickness measurement Outer diameter measurement Average value Insulation machine combing performance Tensile test before aging Tensile test after air oven aging Tensile test after oxygen bomb aging Hot extension test Heat resistance of textile braided layer Test type RX, RXS. RXH 300/300V Test method 2.1 of GB5013.2-1997 2.2 of GB5013.2—1997 GB5013.1 and GB5013.2 Inspection and manual test 1.9 of CB5013.2—1997 1.11 of GB5013.2—1997 9.1 of GB/T 2951.1—1997 4 of GB5013.2—1997 4 of GB5013.2—1997 CB/T 2951. 5-1997, 9 GB5013.2-1997, 6 Inspection items Mechanical strength of finished cable Flexing test and after test Water immersion 2000V voltage test Abrasion test Marking rub test JB 8735.3-1998 Table 5 (end) Test type RX. RXS, RXH 300/300V Test method GB5013.2—1997, 3.1 and 2.2 GB5013.2—1997, 3.3 GB5013.2—1997, 1.8 Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.