SY/T 5504-1996 Evaluation method for oil well cement retarders
Basic Information
Standard ID:
SY/T 5504-1996
Standard Name: Evaluation method for oil well cement retarders
Chinese Name:
油井水泥缓凝剂评价方法
Standard category:Oil and gas industry standards (SY)
state:Abolished
Date of Release1996-12-15
Date of Implementation:1997-06-30
Date of Expiration:2005-11-01
standard classification number
Standard Classification Number:Petroleum>>Petroleum Exploration, Development and Gathering>>E14 Petroleum Production
Publication information
other information
Introduction to standards:
SY/T 5504-1996 Evaluation method for oil well cement retardersSY/T5504-1996 Standard download decompression password: www.bzxz.net
Some standard content:
Petroleum Industry Standardization Technical Committee CPSCSY
Petroleum and Natural Gas Industry Standard of the People's Republic of China SY/ T 5504-1996
Evaluation method for oil well cement retarders
Issued on December 15, 1996
China National Petroleum Corporation
Implementation on June 30, 1997
1 Scope
Technical Specifications Anbei CS
Petroleum and Natural Gas Industry Standard of the People's Republic of China Evaluation method for oil well cement retarders
SY/T 5504-1996
Replaces SY/T5504--92
This standard specifies the technical requirements, test methods, judgment rules and inspection reports for oil well cement retarders. This standard applies to the performance evaluation of oil well cement retarders used in oil and gas well cementing operations. 2
Cited standards
The provisions contained in the following standards constitute the provisions of this standard through reference in this standard. When this standard is published, the versions shown are valid. All standards will be revised, and parties using this standard should explore the possibility of using the latest versions of the following standards. SY5546-92 Oil well cement application performance test method 3 Technical requirements
3.1 Retarder can be divided into liquid or powdered solid products, and the product should be easily soluble in water. Retarder can be divided into two basic types according to the operating temperature range: medium temperature and high temperature. Medium temperature retarder should be suitable for cementing operations with a bottom hole circulation temperature of 3.2
60~90℃, and high temperature retarder should be suitable for cementing operations with a bottom hole circulation temperature of more than 90℃. 3.3
The retarder and its compatible admixture should have good compatibility. 3.4
The performance requirements of cement slurry with medium-temperature retarder are shown in Table 1, and the performance requirements of cement slurry with high-temperature retarder are shown in Table 2. Table 1 Performance requirements of cement slurry with medium-temperature retarder Item
Thickening time (77℃.61MPa)
Initial consistency
The time taken for 40Bc to 100Bc
Compressive strength (106℃.21MPa.24h)
Ratio of 168h compressive strength to 24h compressive strength%
Free water content (77℃.61MPa)
The thickening time should be prolonged with the increase of retarder dosage. Use G grade cement to prepare cement slurry. Water-cement ratio W/C=0.44. 2
3 The contents in brackets are test conditions
Approved by China National Petroleum Corporation on December 15, 1996. First-class product
120~270 adjustable
Second-class product
120~270 adjustable
Qualified product
120~270 adjustable
1997-06-30. Implementation
Petroleum Industry Standardization Technical Committee CPSCSY/T5504-1996
Table 2 Performance requirements of cement slurry with high-temperature retarderFirst-class product
Thickening time (118℃, 111MPa)
Initial consistency
Time from 40Bc to 100Bc
Compressive strength (142℃.21MPa.48h)
Ratio of 168h compressive strength to 48h compressive strengthofo
Thickening time should be prolonged with the increase of retarder dosage. -180~420 adjustable
Secondary product
180~420 adjustable
Qualified product
180~420 adjustable
Use G-grade cement and sand (cement: quartz sand = 100:35) to prepare cement slurry, water-cement ratio W/C = 0.56. The particle size of quartz sand is between 0.095~2
0.075mm (160~200 mesh), and the silicon dioxide content is not less than 96%3The content in brackets is the test conditions
4Test method
4.1 Evaluation of medium-temperature retarder
4.1.1 Preparation of cement slurry
Weigh 792g of G-grade oil well cement and 349g of distilled water, and weigh the retarder according to the dosage range recommended by the manufacturer. The preparation method is in accordance with Chapter 4 of SY5546-92.
4.1.2: Thickening time test
4.1.2.1 Under the test conditions of test temperature of 77℃, initial pressure of 9.4MPa, final pressure of 61MPa and heating time of 40min, the thickening time of cement slurry is determined. The determination method is in accordance with Chapter 6 of SY5546-92. By adjusting the retarder dosage, the thickening time is 120min±10min (No. 1 cement slurry) and 270min±20min (No. 2 cement slurry), and record whether the thickening time is prolonged with the increase of retarder dosage. 4.1.2.2·Record or read the initial consistency of No. 1 cement slurry and No. 2 cement slurry from the thickening curve, and take the larger value. 4.1.2.3 Record or read the time taken by No. 1 cement slurry and No. 2 cement slurry from the thickening curve, and take the larger value. 4.1.3 Compressive strength test
Under the test conditions of curing temperature of 106℃ and curing pressure of 21MPa, No. 2 cement slurry is cured for 24h and 168h respectively. The compressive strength of cement paste with specified curing time is measured respectively, and the ratio of 168h compressive strength to 24h compressive strength is calculated at the same time.
The test method is carried out in accordance with Chapter 10 of SY5546--92·. 4.1.4 Determination of free water content
Stir No. 2 cement slurry in a high pressure thickener according to the test conditions specified in 4.1.2.1, and then measure its free water content. The determination method is in accordance with Chapter 7 of SY5546-92. 2
4.2 Evaluation of high temperature retarder
4.2.1 Preparation of cement slurry
CPSCSY/T 5504-1996, Technical Committee for Standardization of Petroleum Industry
Weigh 594g of G-grade oil well cement, 208g of quartz sand and 333g of distilled water, and weigh the retarder according to the dosage range recommended by the manufacturer. The preparation method is in accordance with Chapter 4 of SY5546-92. 4.2.2 Thickening time test
4.2.2.1 The thickening time of cement slurry is determined under the test conditions of test temperature of 118℃, initial pressure of 13.8MPa, final pressure of 111MPa and heating time of 60min. The determination method is in accordance with Chapter 6 of SY5546-92. By adjusting the amount of retarder, the thickening time is 180min±15min (No. 3 cement slurry) and 420min±30min (No. 4 cement slurry), and record whether the thickening time is extended with the increase of the amount of retarder. 4.2.2.2 Record or read the initial consistency of No. 3 cement slurry and No. 4 cement slurry from the thickening curve, and take the larger value. 4.2.2.3 Record or read the time taken for No. 3 cement slurry and No. 4 cement slurry to reach 40~100Bc from the thickening curve. Take the larger value. 4.2.3 Compressive strength test
Under the test conditions of curing temperature of 142℃ and curing pressure of 21MPa, No. 4 cement slurry is cured for 48h and 1681 respectively. The compressive strength of cement paste at the specified curing time is measured respectively, and the ratio of 168h compressive strength to 48h compressive strength is calculated.
The test method is in accordance with Chapter 10 of SY5546-92. 5 Judgment rules
5.1 If the thickening time does not increase with the increase of the retarder dosage, it is judged as unqualified. 5.2 In the test results, if all items meet the requirements of the first-class product, it is judged as the first-class product; as long as one item does not meet the requirements of the first-class product, but is not lower than the second-class product.It is judged as a second-class product; as long as one item fails to meet the requirements of the second-class product, but is not lower than the qualified product, it is judged as a qualified product; as long as one item fails to meet the requirements of the qualified product, it is judged as an unqualified product. 6 Inspection report
The inspection report (or evaluation report) of oil well cement retarder should indicate the test conditions, cement slurry components, technical indicators and inspection results. Appendix A (Suggestive Appendix) provides a reference inspection report format. Appendix A (Suggestive Appendix)
Name or code:
Manufacturer name:
Product batch number:
Inspected unit:
Sampling (delivery) person:
Sampling (delivery) date:
Thickening time (
Type:
Petroleum Industry Standardization Technical Committee CPSC Inspection Report Formatbzxz.net
Oil well cement retarder inspection report
Inspection unit:
(Official seal)| |tt||Inspection date:
Implementation standard:
Standard requirement value
(Grade:
Initial consistency
Time between 40 and 100Bc
Compressive strength(
Ratio of compressive strength
Free water
Cement slurry
Approval:
Review:
Adjustable
Main inspection:
Inspection results
Year/month/day
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.