Chemical Industry Standard of the People's Republic of China Glass Thermometer Cover 1 Subject content and scope of application HG/T2058.1-91 This standard specifies the structure and assembly type, parameters, main dimensions and technical requirements of glass thermometer covers. This standard applies to thermometer covers for glass mixing vessels with nominal pressure less than or equal to 1.0 MPa, medium temperature higher than -20℃ and lower than or equal to 20℃, equipped with anchor or frame agitators. It is also applicable to thermometer covers for mixing vessels equipped with paddle or impeller agitators, with nominal diameter of the container less than or equal to 500 mm. 2 Reference standards GB700 Carbon structural steel GB5679 Malleable cast iron GB7994 Hydrostatic test method for glass equipment GB7996 Nominal volume and nominal diameter of glass container GB8163 Seamless steel pipe for conveying fluids ZBG94004 Technical conditions for glass equipment HG/T2050 Gasket for glass equipment HG/T2105 Loose flange for glass equipment 3 Types, basic parameters and main dimensions 3.1 Thermometer cover structure is divided into Type A There are two types: type A and type B. Type A is a thermometer sleeve without a temperature measuring head device. Its basic parameters and main dimensions are shown in Figure 1, Table 1, Table 2, Table 3, Table 5, and Table 6. Type B is a thermometer sleeve with a temperature measuring head device. Its minimum nominal diameter is dN50. Its basic parameters and main dimensions are shown in Figure 2, Table 1, Table 3, Table 4, and Table 5. 3.2 The installation methods of the thermometer sleeve are divided into type 1 and type 3, see Table 1.3.3 Marking: Standard No.||tt ||Thermowell length L Nominal diameter of thermometer sleeve dN Nominal pressure of container PN Type and installation method of thermometer sleeve Name: Thermometer sleeve Marking example: Thermowell without temperature measuring head device, its installation angle α is 7°, the nominal pressure of container PN is 0.6MPa, the nominal diameter of thermometer sleeve dN is 65mm, and the length H is 1000mm. Approved by the Ministry of Chemical Industry of the People's Republic of China on July 6, 1991 and implemented on January 1, 1992 HG/T2058.1- Marking: Thermometer sleeve AⅡ0.6×65-1000HG/T2058.1-9M27×2 Surface sugar glass Surface sugar glass HG/T 2058.1 Installation method HG/T2058.1—91 Installation angle α Note: Installation method I is suitable for matching frame agitators, and installation method II is suitable for matching anchor agitators. Table 2 GB5782-86 GB617086 HG/T2105--91bZxz.net HG/T2050-91 Nominal diameter of thermometer sleeve Matched pipe outlet Nominal diameter Loop flange Details Table 3 Size table||tt ||Glass Q235-A Assembly KTH350 or Q235-A Q235-A See Table 3 See Table 3 ①A-type thermometer sleeve dN32 specification, the 25×3.5 in the end diameter section can be cancelled, and it is made of Φ32×4 pipe for direct sealing, but the height H remains unchanged. Note: ②B-type thermometer sleeve has no dN32 specification. HG/T2050—91 HG/T2105—91 GB5782—86 GB6170-86 GB 97. 1—85 GB 985.1—86 GB1235—76 WEPM-018 HG/T2058.1—91 Details Junction box Loop-type flange Wire retaining ring O-ring 28×3.5 Overflow measuring head casing Compression spring 0.8×8×30 Ceramic end face platinum resistor Assembly KTH350 or Q235-A Assembly Q235-A Glass parts Q235-A Polytetrafluoroethylene Red paper cypress||t t||Fittings See Table 3 Thermometer sleeve Nominal diameter Volume VN Mixed mixing container Nominal diameter DN L series HG/T2058.1—91 Table 5 Dimension table Installation angle S series Anchor type Agitator Frame type Agitator Reference weight kg Anchor type Agitator 10.8/12.5 11.3/13.0 11.0/12.7 11.4/ 13.2 | | tt | /12.3 10.3/12.1 10.6/12.3 10.5/12.2 10.9/12.8 20.3/2 0.8 19.3/19.8 21.1/21.6 21.1/21.6 Thermometer sleeve Nominal diameter Volume VN Mixed mixing vessel Nominal diameter DN L series HG/T2058.1—91 Installation angle s series Anchor type Agitator Frame type Agitator Reference weight kg||tt ||Anchor type Agitator 28.6/31.8 31.5/34.8 30.0/33.3 33.0/36.3 Note: The values in the reference weight column of Table 5: the numerator is the reference weight for PN0.6: the denominator is the reference weight for PN1.0. mm Frame type Agitator 25.6/28.9 27.8/31.1 26.3/29.6 29.3/ 32.6 26.3/29.6 Thermometer sleeve Nominal diameter Volume VN Matched mixing vessel HG/T2058.1- Table 6 Dimension table Installation angle Nominal diameter DN L series s series Matched paddle or impeller Matched mixing vessel Note: The values in the reference weight column of Table 6: the numerator is the reference weight for PN0.6; the denominator is the reference weight for PN1.0. 4 Technical requirements 4.1 The steel pipe material used for the thermometer sleeve is No. 10 steel, and it is accepted according to GB8163. 4.2 The technical conditions of the thermometer sleeve of the thermometer glass shall be in accordance with the requirements of ZBG94004, mm Reference weight, kg 4.3 After the B-type thermometer sleeve is assembled, it shall be subjected to a water pressure test together with the equipment installed according to the test pressure after the thermometer glass specified in Table 1 of GB7994 standard. The test pressure is the nominal pressure of the container installed, and the test result should show no leakage. 4.4 The material of the thermometer sleeve can be provided according to user needs, but it must be resistant to corrosion by the working medium. 5 Packaging, transportation and storage 5.1 The surface of the thermometer glass should be wrapped with soft objects and firmly fixed in the wooden box. 5.2 Collision is prohibited during handling or transportation, and the packaging box shall not be inverted. 5.3 The product should be accompanied by a packing list, a certificate of conformity and an instruction manual. 5.4 Products should be stored indoors, and are not allowed to be stacked or inverted in the open air. Additional notes: This standard was proposed by China National Chemical Equipment Corporation. This standard is under the jurisdiction of the National Standardization Technical Committee for Glass Equipment. This standard was drafted by Shanghai Industrial Glass Porcelain Factory, and the Shanghai Pharmaceutical Design Institute of the State Pharmaceutical Administration participated in the drafting. The main drafter of this standard is Gu Guoyang, and the co-drafters are Bao Aiyuan and Huang Yinhua. From the date of implementation of this standard, the former Ministry of Chemical Industry standard HG5-275-79 "Thermometer Cover for Glass Equipment" will be invalidated. Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.